Vladimir A. Smalyuk

Vladimir A. Smalyuk

Auto-generated profile, based on publicly available information

Vladimir A. Smalyuk

Lawrence Livermore National Laboratory 1 , 7000 East Avenue, Livermore, California 94550

Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2019 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
PDF file
VSVladimir A Smalyuk
Vladimir A Smalyuk
CWChristopher R Weber
Christopher R Weber
OLOtto L Landen
Otto L Landen
SASuzanne Ali
Suzanne Ali
BBBenjamin Bachmann
Benjamin Bachmann
TDTilo Doeppner
Tilo Doeppner
Hydrodynamic instabilities are a major factor in degradation of inertial confinement fusion (ICF) implosions. In the highest performing implosions on National Ignition Facility, yield amplification (YA) due to alpha particle heating approached ∼3, while YA of ∼15–30 is needed for ignition. Understanding and mitigation of the instabilities are critical to achieving ignition. This article reviews several experimental platforms that have been developed to directly measure these instabilities in all phases of ICF implosions. Measurements of ripple-shock propagation at OMEGA laser has provided results on initial seeds for the instabilities in three ablators—plastic (CH), beryllium, and high-density carbon. At the ablation front, instability growth of pre-imposed modulations was measured in the linear regime using the hydrodynamic growth radiography platform. This platform was extended for modulation growth of ‘native roughness’ modulations and engineering features (fill tubes and capsule support membranes or ‘tents’). Several new experimental platforms have or are being developed to measure instability growth at the ablator–ice interface. In the deceleration phase of implosions, complementary ‘self-emission’ and ‘self-backlighting’ platforms were developed to measure low-mode asymmetries and high-mode perturbations near peak compression.

1 July 2018 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
VSV. A. Smalyuk
V. A. Smalyuk
HRH. F. Robey
H. F. Robey
CAC. L. Alday
C. L. Alday
PAP. Amendt
P. Amendt
CAC. Aracne-Ruddle
C. Aracne-Ruddle
CWC. R. Weber
C. R. Weber
Hydrodynamic instability growth of capsule support membranes (or “tents”) has been recognized as one of the major contributors to the performance degradation in high-compression plastic capsule implosions at the National Ignition Facility (NIF) [E. M. Campbell et al., AIP Conf. Proc. 429, 3 (1998)]. The capsules were supported by tents because the nominal 10-μm diameter fill tubes were not strong enough to support capsules by themselves in indirect-drive implosions on NIF. After it was recognized that the tents had a significant impact of implosion's stability, new alternative support methods were investigated. While some of these methods completely eliminated tent, other concepts still used tents, but concentrated on mitigating their impact. The tent-less methods included “fishing pole” reinforced fill tubes, cantilevered fill tubes, and thin-wire “tetra cage” supports. In the “fishing pole” concept, a 10-μm fill tube was inserted inside 30-μm fill tube for extra support with the connection point located 300 μm away from the capsule surface. The cantilevered fill tubes were supported by 12-μm thick SiC rods, offset by up to 300 μm from the capsule surfaces. In the “tetra-cage” concept, 2.5-μm thick wires (carbon nanotube yarns) were used to support a capsule. Other concepts used “polar tents” and a “foam-shell” to mitigate the effects of the tents. The “polar tents” had significantly reduced contact area between the tents and the capsule compared to the nominal tents. In the “foam-shell” concept, a 200-μm thick, 30 mg/cc SiO2 foam layer was used to offset the tents away from the capsule surface in an attempt to mitigate their effects. These concepts were investigated in x-ray radiography experiments and compared with perturbations from standard tent support. The measured perturbations in the “fishing pole,” cantilevered fill tube, and “tetra-cage” concepts compared favorably with (were smaller than) nominal tent perturbations and were recommended for further testing for feasibility in layered DT implosions. The “polar tents” were tested in layered DT implosions with a relatively-stable “high-foot” drive showing an improvement in neutron yield in one experiment compared to companion implosions with nominal tents. This article reviews and summarizes recent experiments on these alternate capsule support concepts. In addition, the concept of magnetic levitation is also discussed.

16 August 2023 in Physical Review E
Verified
Journal Article
Open access
PDF file
CWC. R. Weber
C. R. Weber
DCD. S. Clark
D. S. Clark
DCD. T. Casey
D. T. Casey
GHG. N. Hall
G. N. Hall
OJO. Jones
O. Jones
VSV. A. Smalyuk
V. A. Smalyuk
In inertial confinement fusion (ICF) implosions, the interface between the cryogenic DT fuel and the ablator is unstable to shock acceleration (the Richtmyer-Meshkov instability, RM) and constant acceleration (Rayleigh-Taylor instability, RT). Instability growth at this interface can reduce the final compression, limiting fusion burnup. If the constant acceleration is in the direction of the lighter material (negative Atwood number), the RT instability produces oscillatory motion that can stabilize against RM growth. Theory and simulations suggest this scenario occurred at early times in some ICF experiments on the National Ignition Facility, possibly explaining their favorable performance compared to one-dimensional simulations. This characteristic is being included in newer, lower adiabat designs, seeking to improve compression while minimizing ablator mixing into the fuel.

1 June 2024 in Physics of Plasmas
Verified
Journal Article
Open access
PDF file
OLO. L. Landen
O. L. Landen
RNR. C. Nora
R. C. Nora
JLJ. D. Lindl
J. D. Lindl
AKA. L. Kritcher
A. L. Kritcher
SHS. W. Haan
S. W. Haan
RTR. P. J. Town
R. P. J. Town
We present quantitative motivations and assessments of various proposed and ongoing directions to further improving yields and target gain of igniting indirect-drive implosions at the National Ignition Facility (NIF). These include increasing compression and confinement time, improving hohlraum and ablator efficiency, and further increasing peak power and laser energy. 1D hydroscaled simulations, augmented by analytic 1D theory, have been used to project yield improvements for each of these implosion optimization tracks, normalized to the best current performing 4 MJ shot. At current NIF capabilities of 2.2 MJ, 450 TW, we project several paths could reach 15 MJ yield levels. We also expect several key implosion physics questions will be addressed in attempting to reach this yield level. These include demonstrating to what extent lower adiabat designs leading to higher compression will increase gain and efficiency, and whether we can reduce residual kinetic energy and ablator-fuel mix that is probably limiting the current burn-up fraction. For an envisaged NIF upgrade to EL = 3 MJ at fixed 450 TW peak power, scaling capsule size and fuel thicknesses faster than pure hydroscaling should allow for yields that could reach up to 60–80 MJ, depending on the efficiency gains realized in increasing deuterium-tritium fuel thickness, reducing hohlraum losses, and switching to lower Z ablators. The laser-plasma instability and beam transmission scaling in these larger hohlraums is shown to be favorable if the spot size is increased with hohlraum scale.

20 December 2024 in Plasma Physics and Controlled Fusion
Verified
Journal Article
Closed access
OHO A Hurricane
O A Hurricane
AAA Allen
A Allen
BBB L Bachmann
B L Bachmann
KBK L Baker
K L Baker
SBS Baxamusa
S Baxamusa
AZA B Zylstra
A B Zylstra
For many decades, the running joke in fusion research has been that ‘fusion’ is thirty years away and always will be. Yet, these past few years we find ourselves in a position where we can now talk about the milestones of burning plasmas, fusion ignition, and target energy gain greater than unity (scientific breakeven) in the past tense. Fusion is no longer a joke! Yet getting to fusion ignition, the tipping-point of thermonuclear instability resulting in an explosive increase in ion thermal temperature and fusion reaction-rate, and scientific breakeven (target gain, G target = fusion yield/deposited laser energy > 1 , in the laser-driven inertial confinement fusion context) has not been easy. In this publication we discuss our present understanding of the physics and technological challenges surrounding ignition and Gain as well as highlight some outstanding problems that still need resolution.

1 August 2018 in Physics of Plasmas
Verified
Journal Article
Closed access
PDF file
BHB. A. Hammel
B. A. Hammel
CWC. R. Weber
C. R. Weber
MSM. Stadermann
M. Stadermann
CAC. L. Alday
C. L. Alday
CAC. Aracne-Ruddle
C. Aracne-Ruddle
VSV. A. Smalyuk
V. A. Smalyuk
In indirectly driven Inertial Confinement Fusion implosions conducted on the National Ignition Facility (NIF), the imploding capsule is supported in a laser-heated radiation enclosure (called a “hohlraum”) by a pair of very thin (∼15–45 nm) plastic films (referred to as a “tent”). Even though the thickness of these tents is a small fraction of that of the spherical capsule ablator (∼165 μm), both numerical simulations as well as experiments indicate that this capsule support mechanism results in a large areal density (ρR) perturbation on the capsule surface at the contact point where the tent departs from the capsule. As a result, during deceleration of the deuterium-tritium (DT) fuel layer, a jet of the dense ablator material penetrates and cools the fuel hot spot, significantly degrading the neutron yield (resulting in only ∼10%–20% of the unperturbed 1-D yield). In this article, we present a hypothesis and supporting design simulations of a new “polar contact” tent support system, which reduces the contact area between the tent and the capsule and results in a significant improvement in the capsule performance. Simulations predict a ∼70% increase in neutron yield over that for an implosion with a traditional tent support. An initial demonstration experiment was conducted on the NIF and produced highest ever recorded primary DT neutron yield among all layered DT implosions with plastic ablators on the NIF, though more experiments are needed to comprehensively study the effect of the polar tent on implosion performance.