Cedric Müller

Cedric Müller

Auto-generated profile, based on publicly available information

Cedric Müller

Karlsruhe Institute of Technology (KIT) Institute for Applied Materials (IAM) Hermann-von-Helmholtz-Platz 1 76344 Eggenstein-Leopoldshafen Germany

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 December 2023 in Batteries & Supercaps
Verified
Journal Article
Open access
PSPirmin Stüble
Pirmin Stüble
CMCedric Müller
Cedric Müller
JKJulian Klemens
Julian Klemens
PSPhilip Scharfer
Philip Scharfer
WSWilhelm Schabel
Wilhelm Schabel
ASAnna Smith
Anna Smith
Sodium‐ion batteries are becoming an increasingly important complement to lithium‐ion batteries. However, while extensive knowledge on the preparation of Li‐ion batteries with excellent cycling behavior exists, studies on applicable long‐lasting sodium‐ion batteries are still limited. Therefore, this study focuses on the cycling stability of batteries composed of Na3V2(PO4)3/C based cathodes and hard carbon anodes. It is shown that full‐cells with a decent stability are obtained for ethylene carbonate/propylene carbonate electrolyte and the conducting salt NaPF6. With cathode loadings of 1.2 mAh/cm2, after cell formation discharge capacities up to 92.6 mAh/g are obtained, and capacity retentions >90 % over 1000 charge/discharge cycles at 0.5 C/0.5 C are observed. It is shown that both, the additive fluoroethylene carbonate and impurities in the electrolyte, negatively affect the overall discharge capacity and cycling stability and should therefore be avoided. Remarkably, the internal resistances of well‐balanced and well‐built cells did not increase over 1500 cycles and 5 months of testing, which is a very promising result regarding the possible lifespan of the cells. The initial loss of active sodium ions in hard carbon remains a major problem, which can only be partially reduced by proper balancing.

6 September 2024 in Batteries & Supercaps
Verified
Journal Article
Open access
PDF file
PSPirmin Stüble
Pirmin Stüble
CMCedric Müller
Cedric Müller
NBNicole Bohn
Nicole Bohn
MMMarcus Müller
Marcus Müller
AHAndreas Hofmann
Andreas Hofmann
ASAnna Smith
Anna Smith
At the research level, novel active materials for batteries are synthesised on a small scale, fabricated into electrodes and electrochemically characterised using each group's established process due to the lack of standards. Recently, eminent researchers have criticised the implementation of e. g. low active material contents/electrode loadings, the use of research‐type battery cell constructions, or the lack of statistically relevant data, resulting in overstated data and thus giving misleading predictions of the key performance indicators of new battery technologies. Here, we report on the establishment of a reference system for the development of sodium‐ion batteries. Electrodes are fabricated under relevant conditions using 9.5 mg/cm 2 self‐synthesised Na 3 V 2 (PO 4 ) 3 /C cathode active material and 3.6 mg/cm 2 commercially available hard carbon anode active material. It is found that different types of battery cells are more or less suitable for half‐ and/or full‐cell testing, resulting in ir/reproducible or underestimated active material capacities. Furthermore, the influence of electrode overhang, which is relevant for upscaling, is evaluated. The demonstrator cell (TRL 4–5) has been further characterised providing measured data on the power/energy density and thermal behaviour during rate testing up to 15 C and projections are made for its practical limits.

28 September 2023 in Batteries & Supercaps
Verified
Journal Article
Open access
CMCedric Müller
Cedric Müller
ZWZhengqi Wang
Zhengqi Wang
AHAndreas Hofmann
Andreas Hofmann
PSPirmin Stüble
Pirmin Stüble
XLXinyang Liu‐Théato
Xinyang Liu‐Théato
ASAnna Smith
Anna Smith
For the development of a full‐cell battery system, typically appropriate cathodes and anodes are characterized within a half‐cell setup where a metal counter electrode is installed to gather data about the employed electrodes. Ultimately, the individual capacity loadings allow for suitable balancing of the anode to cathode capacity in the full‐cell. This approach seems rather unproblematic for lithium‐ion batteries. For sodium‐ion batteries, however, we show that the high reactivity of sodium metal strongly influences hard carbon‐based electrode measurements within sodium‐ion half‐cells. As hard carbon is considered state‐of‐the‐art anode material, the presented results have high impact on the development of sodium ion batteries. Specifically, we show that the type of electrolyte, as well as cell‐ and measurement‐setup are key factors for reliable sodium half‐cell measurements of hard carbon. The investigated hard carbon electrodes have a high active material loading of 7.2 mg/cm2 (with 93 % active material content) resulting in an areal capacity of 2.4 mAh/cm2, which represent application‐relevant conditions.

9 August 2024 in ECS Meeting Abstracts
Verified
Journal Article
Closed access
CMCedric Müller
Cedric Müller
ZWZhengqi Wang
Zhengqi Wang
AHAndreas Hofmann
Andreas Hofmann
PSPirmin Stüble
Pirmin Stüble
XLXinyang Liu-Théato
Xinyang Liu-Théato
ASAnna Smith
Anna Smith
Lithium-ion batteries (LIBs) are the current state of the art energy storage technology. However, to tackle the steady increasing demand for clean but also sustainable energy, other complementary cell chemistries are gaining significant importance. Sodium-ion batteries (NIBs) are considered to be a drop-in technology that can benefit from the knowledge about processing of LIBs and its existing manufacturing structures. For the development of a sodium-ion full-cell, commercially available hard carbon (HC) as an anode material was characterized within a half-cell setup. On the one hand, those measurements are essential to characterize individual electrodes in order to obtain electrochemical information that is needed to set up the full cell, e.g. balancing. On the other hand, the exact determination of the HC capacity is prone to errors, mainly due to the cut-off potential being close to 0 V against metallic sodium. This behavior and also electrolyte degradation in presence of elemental sodium were studied. It has been found that the potential of the current carrying sodium counter electrode in half-cells is not stable, resulting in measurement inaccuracies, particularly at elevated C-rates when charging is controlled by a cut-off potential. On the contrary, by using a three-electrode setup, the current-free reference electrode provides stable cut-off conditions. An improved setup for half-cell measurements is suggested to obtain reliable and reproducible capacity readings for HC anodes with an areal capacity of up to 2.4 mAh/cm². Figure : Schematic overview about the investigated control voltages and their effect on the electrochemical performance. [1] The initial coulombic efficiency (ICE) of HC is a current challenge because it is relatively low at about 80% and it can vary for different HC materials. Therefore, precise measurements are a necessity to develop HC materials with higher ICEs. Funded by the Deutsche Forschungsgemeinschaft (DFG, German Research Foundation) under Germany’s Excellence Strategy – EXC 2154. [1] Müller, C., Wang, Z., Hofmann, A., Stüble, P., Liu-Théato, X., Klemens, J., Smith, A., “Influences on Reliable Capacity Measurements of Hard Carbon in Highly Loaded Electrodes” Batteries & Supercaps 2023, e202300322. Figure 1