Faculty of Electrical Engineering, Mathematics and Computer Science (EEMCS), Robotics and Mechatronics Group, University of Twente, Enschede, The Netherlands

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2021 in Current Robotics Reports
Verified
Journal Article
Open access
PDF file
FSFrançoise J. Siepel
Françoise J. Siepel
BMBogdan Mihai MARIS
Bogdan Mihai MARIS
MWMarcel K. Welleweerd
Marcel K. Welleweerd
VGVincent Groenhuis
Vincent Groenhuis
PFPaolo Fiorini
Paolo Fiorini
SSStefano Stramigioli
Stefano Stramigioli
Purpose of the review: Robotics is a rapidly advancing field, and its introduction in healthcare can have a multitude of benefits for clinical practice. Especially, applications depending on the radiologist’s accuracy and precision, such as percutaneous interventions, may profit. This paper provides an overview of recent robot-assisted percutaneous solutions. Recent findings: Percutaneous interventions are relatively simple and the quality of the procedure increases a lot by introducing robotics due to the improved accuracy and precision. The success of the procedure is heavily dependent on the ability to merge pre- and intraoperative images, as an accurate estimation of the current target location allows to exploit the robot’s capabilities. Summary: Despite much research, the application of robotics in some branches of healthcare is not commonplace yet. Recent advances in percutaneous robotic solutions and imaging are highlighted, as they will pave the way to more widespread implementation of robotics in clinical practice.

21 May 2018 in Annals of Biomedical Engineering
Verified
Journal Article
Open access
PDF file
VGVincent Groenhuis
Vincent Groenhuis
FSFrançoise J. Siepel
Françoise J. Siepel
JVJeroen Veltman
Jeroen Veltman
JZJordy K. van Zandwijk
Jordy K. van Zandwijk
SSStefano Stramigioli
Stefano Stramigioli
Suspicious lesions in the breast that are only visible on magnetic resonance imaging (MRI) need to be biopsied under MR guidance with high accuracy and efficiency for accurate diagnosis. The aim of this study is to present a novel robotic system, the Stormram 4, and to perform preclinical tests in an MRI environment. Excluding racks and needle, its dimensions are 72 × 51 × 40 mm. The Stormram 4 is driven by two linear and two curved pneumatic stepper motors. The linear motor is capable of exerting 63 N of force at a pressure of 0.65 MPa. In an MRI environment the maximum observed stepping frequency is 30 Hz (unloaded), or 8 Hz when full force is needed. The Stormram 4’s mean positioning error is 0.73 ± 0.47 mm in free air, and 1.29 ± 0.59 mm when targeting breast phantoms in MRI. Excluding the off-the-shelf needle, the robot is inherently MR safe. The robot is able to accurately target lesions under MRI guidance, reducing tissue damage and risk of false negatives. These results are promising for clinical experiments, improving the quality of healthcare in the field of MRI-guided breast biopsies.

25 May 2018 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Open access
VGVincent Groenhuis
Vincent Groenhuis
SSStefano Stramigioli
Stefano Stramigioli
In this paper we show that pneumatic stepper motors for MR safe robots can be constructed using rapid prototyping techniques such as 3-D printing and laser-cutting. The designs are lightweight, completely metal-free and fully customizable. Besides MR safe robotic systems, other potential applications include high-voltage switchgear and nuclear power plant systems which also restrict electric actuation. In addition, it can be applied to other actuation systems where pressurized air is available and lightweight, rapid prototypeable actuators are needed. Five pneumatically-driven linear and rotational stepper motors have been developed with forces up to 330 N, torques up to 3.7 Nm, stepping frequency up to 320 Hz, dimensions ranging from 25 mm to 80 mm, free of backlash and power up to 26 W. All five motors are constructed from six 3-D printed parts and four seals, held together by nylon screws or clips. The described stepper motors outperform state-of-the-art plastic pneumatic stepper motor designs, both in specifications and in manufacturability.

11 January 2021 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
ANAnton V. Nikolaev
Anton V. Nikolaev
LJLeon de Jong
Leon de Jong
GWGert Weijers
Gert Weijers
VGVincent Groenhuis
Vincent Groenhuis
RMRitse M. Mann
Ritse M. Mann
CKChris L. de Korte
Chris L. de Korte
Breast cancer is one of the most diagnosed types of cancer worldwide. Volumetric ultrasound breast imaging, combined with MRI can improve lesion detection rate, reduce examination time, and improve lesion diagnosis. However, to our knowledge, there are no 3D US breast imaging systems available that facilitate 3D US - MRI image fusion. In this paper, a novel Automated Cone-based Breast Ultrasound System (ACBUS) is introduced. The system facilitates volumetric ultrasound acquisition of the breast in a prone position without deforming it by the US transducer. Quality of ACBUS images for reconstructions at different voxel sizes (0.25 and 0.50 mm isotropic) was compared to quality of the Automated Breast Volumetric Scanner (ABVS) (Siemens Ultrasound, Issaquah, WA, USA) in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and resolution using a custom made phantom. The ACBUS image data were registered to MRI image data utilizing surface matching and the registration accuracy was quantified using an internal marker. The technology was also evaluated in vivo. The phantom-based quantitative analysis demonstrated that ACBUS can deliver volumetric breast images with an image quality similar to the images delivered by a currently commercially available Siemens ABVS. We demonstrate on the phantom and in vivo that ACBUS enables adequate MRI-3D US fusion. To our conclusion, ACBUS might be a suitable candidate for a second-look breast US exam, patient follow-up, and US guided biopsy planning.

10 May 2017 in IEEE Robotics & Automation Magazine
Verified
Journal Article
Closed access
VGVincent Groenhuis
Vincent Groenhuis
JVJeroen Veltman
Jeroen Veltman
FSFrancoise J Siepel
Francoise J Siepel
SSStefano Stramigioli
Stefano Stramigioli
Stormram 3 is a magnetic resonance imaging (MRI)-compatible robotic system that can perform MR-guided breast biopsies of suspicious lesions. The base of the robot measures 160 # 180 # 90 mm, and it is actuated by five custom pneumatic linear stepper motors, driven by a valve manifold outside the Faraday cage of the MRI scanner. All parts can be rapidly prototyped with three-dimensional (3-D) printing or laser cutting, making the design suitable for other applications, such as actuation in hazardous environments. Based on the choice of materials, the robot (with the exception of the needle) is inherently MR safe. Measurements show that the maximum force of the T-49 actuator is 70 N, at a pressure of 0.3 MPa. The Stormram 3 has an optimized repeatability that is lower than 0.5 mm, and it can achieve a positional accuracy on the order of 2 mm.

11 December 2015 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Open access
VGVincent Groenhuis
Vincent Groenhuis
SSStefano Stramigioli
Stefano Stramigioli
Pneumatic devices require tight tolerances to keep them leak-free. Specialized companies offer various off-the-shelf devices, while these work well for many applications, there are also situations where custom design and production of pneumatic parts are desired. Cost efficiency, design flexibility, rapid prototyping, and MRI compatibility requirements are reasons why we investigated a method to design and produce different pneumatic devices using a laser cutter from acrylic, acetal, and rubber-like materials. The properties of the developed valves, pneumatic cylinders, and stepper motors were investigated. At 4-bar working pressure, the 4/3-way valves are capable of 5-Hz switching frequency and provide at most 22-L/min airflow. The pneumatic cylinder delivers 48 N of force, the acrylic stepper motor 30 N. The maximum switching frequency over 6-m long transmission lines is 4.5 Hz, using 2-mm tubing. A MRI-compatible robotic biopsy system driven by the pneumatic stepper motors is also demonstrated. We have shown that it is possible to construct pneumatic devices using laser-cutting techniques. This way, plastic MRI-compatible cylinders, stepper motors, and valves can be developed. Provided that a laser-cutting machine is available, the described pneumatic devices can be fabricated within hours at relatively low cost, making it suitable for rapid prototyping applications.