Anton V. Nikolaev

Anton V. Nikolaev

Auto-generated profile, based on publicly available information

Anton V. Nikolaev

Medical Ultrasound Imaging Center, Department of Medical Imaging, Radboud University Medical Center, Nijmegen, Netherlands

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 January 2021 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
ANAnton V. Nikolaev
Anton V. Nikolaev
LJLeon de Jong
Leon de Jong
GWGert Weijers
Gert Weijers
VGVincent Groenhuis
Vincent Groenhuis
RMRitse M. Mann
Ritse M. Mann
CKChris L. de Korte
Chris L. de Korte
Breast cancer is one of the most diagnosed types of cancer worldwide. Volumetric ultrasound breast imaging, combined with MRI can improve lesion detection rate, reduce examination time, and improve lesion diagnosis. However, to our knowledge, there are no 3D US breast imaging systems available that facilitate 3D US - MRI image fusion. In this paper, a novel Automated Cone-based Breast Ultrasound System (ACBUS) is introduced. The system facilitates volumetric ultrasound acquisition of the breast in a prone position without deforming it by the US transducer. Quality of ACBUS images for reconstructions at different voxel sizes (0.25 and 0.50 mm isotropic) was compared to quality of the Automated Breast Volumetric Scanner (ABVS) (Siemens Ultrasound, Issaquah, WA, USA) in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and resolution using a custom made phantom. The ACBUS image data were registered to MRI image data utilizing surface matching and the registration accuracy was quantified using an internal marker. The technology was also evaluated in vivo. The phantom-based quantitative analysis demonstrated that ACBUS can deliver volumetric breast images with an image quality similar to the images delivered by a currently commercially available Siemens ABVS. We demonstrate on the phantom and in vivo that ACBUS enables adequate MRI-3D US fusion. To our conclusion, ACBUS might be a suitable candidate for a second-look breast US exam, patient follow-up, and US guided biopsy planning.

8 December 2020 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
VGVincent Groenhuis
Vincent Groenhuis
ANAnton Nikolaev
Anton Nikolaev
SNSaskia H. G. Nies
Saskia H. G. Nies
MWMarcel K. Welleweerd
Marcel K. Welleweerd
LJLeon de Jong
Leon de Jong
SSStefano Stramigioli
Stefano Stramigioli
Biopsy of breast lesions only visible on MRI may benefit from patient-specific finite-element modeling of the breast. This requires acquisition of the heterogeneous elasticity distribution. An acoustically transparent pad has been developed which enables strain elastography imaging using ultrasound without need for additional force or pressure sensors. The elasticity of the pad is known a priori while the change in thickness is detectable on ultrasound by edge detection. Based on the calculated pressure distribution across the pad, the pressure in inner tissue can be approximated. The strain is measured using a cross-correlation block matching algorithm and from these measurements the heterogeneous elasticity distribution can be estimated. The ultrasound probe with pad is moved over the breast surface by a robot arm. At sixteen sites on the surface of one phantom the probe with pad performed an inward push movement perpendicular to the breast surface. The ultrasound scans were post-processed to reconstruct a heterogeneous elasticity map in the local imaging plane. While it is challenging to accurately estimate the stress and strain in deeper tissue, certain features such as the skin can be effectively distinguished from the underlying soft tissue which demonstrates the potential of the system.

23 August 2022 in Frontiers in Physics
Verified
Journal Article
Open access
ANAnton V. Nikolaev
Anton V. Nikolaev
HHHendrik H. G. Hansen
Hendrik H. G. Hansen
TMThomas J. J. Maal
Thomas J. J. Maal
NANens van Alfen
Nens van Alfen
CKChris L. de Korte
Chris L. de Korte
Free-hand volumetric ultrasound (FVUS) facilitates 3D US imaging of large anatomical areas. However, this method is user-dependent and image quality, especially in the scan direction (elevational direction), depends on the number of US images acquired per distance unit. This might affect clinical decision making for example in quantitative ultrasound muscle imaging. This study addresses three goals. First, to determine quantitatively below which number of acquisitions per cm (acq/cm) image quality is affected: the acquisition limit. Second, to determine the translation speed used naturally by sonographers. Third, to demonstrate in vivo possible benefits of utilizing plane wave imaging for FVUS, so-called fast FVUS in order to boost translation speed while maintaining quantitative image information. Fast FVUS enables imaging at much higher framerates and hence the acquisition limit is easier met which allows for much faster transducer translation. From an analysis of the contrast and elevational resolution in a phantom, the average acquisition limit was determined to be 33 acq/cm. Above this limit, the quantitative ultrasound information remained unchanged. This would imply that when imaging at 30 frames per second, a common frame-rate of current 2D ultrasound devices, suboptimal imaging quality is obtained above transducer translation speeds of 9.1 mm/s. The median and maximum transducer translation speed observed in 10 sonographers were 15.8 mm/s and 30.1 mm/s, thus above this limit. Finally, we presented a design of fast FVUS that enabled acquiring 200 fps, and hence, would allow imaging up to speeds of 60.6 mm/s. We demonstrated in vivo in tibialis anterior muscles that more anatomical details were visible with fast FVUS which were lost at the typical framerate. These observations support our hypothesis that fast FVUS would be an ideal method for 3D quantitative muscle ultrasound.

7 September 2020
Verified
Conference Paper
Closed access
ANAnton V. Nikolaev
Anton V. Nikolaev
LJLeon de Jong
Leon de Jong
VGVincent Groenhuis
Vincent Groenhuis
MWMarcel K. Welleweerd
Marcel K. Welleweerd
FSFrançoise J. Siepel
Françoise J. Siepel
CKChris L. de Korte
Chris L. de Korte
Adding volumetric ultrasound (3DUS) to MRI improves cancer detection rate in a breast. However, the fusion of 3DUS and MRI is challenging due to the different position (supine versus prone, respectively) and high deformation of a breast in the existing 3DUS scanners. In this study, we present and quantitatively evaluate a novel robot-assisted breast scanning system for 3D US acquisitions. Since the breast is scanned in a prone position with minimal and measurable deformation, this can facilitate MRI - 3DUS fusion. For quantitative evaluation, a breast-shaped rigid polyvinyl-alcohol phantom was constructed containing spherical lesions (15 mm diameter) with different echogenicity (−22 dB, −5 dB, −4 dB, 3 dB, 7 dB). First, the phantom was scanned with a Siemens Skyra 3T MRI (Siemens Healthcare, Erlangen, Germany). Next, the phantom was scanned by a robotic arm (KUKA, Augsburg, Germany) (Fig. 1a.) following a pre-planned spiral trajectory, determined from the MRI volume. The flange of the robot was equipped with an L10-5v US transducer attached to a P500 system (Siemens, Mountain View, CA, US). 2D B-mode US data were acquired for 3 minutes at 12 fps. The imaging depth was 5 cm, and the focal depth was set at 2 cm. A volume of 77 × 77 × 69 mm3 was reconstructed with an isotropic sampling distance of 0.2 mm utilizing a voxel nearest neighbor method with a subsequent “hole filling” step, i.e. interpolation. The contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) were calculated per lesion and compared to reference values from the originally acquired 2D B-mode images. The 3D US volume was registered to the MRI volume by using 4 lesions as landmark, using rigid registration. The distance between the centers of the remaining lesion in MRI and 3DUS after the registration was calculated. The measurement was repeated for 5 combinations between lesions and landmarks. The average distance was used as a measure of registration accuracy. For the reconstructed volume only 24 % of the data were obtained by interpolation. On average, the CNR and SNR were 24% and 6% higher, respectively, for the 3DUS compared to the reference. The registration accuracy was 3.4 mm; hence, the presented scanning approach enables ultrasound breast 3D imaging in prone position facilitating MRI - 3D US fusion.