David R. Miller

David R. Miller

Auto-generated profile, based on publicly available information

David R. Miller

Department of Biomedical Engineering, The University of Texas at Austin, 107 W. Dean Keeton C0800, Austin, TX 78712, USA

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2017 in Current Opinion in Biomedical Engineering
Verified
Journal Article
Closed access
DMDavid R. Miller
David R. Miller
JJJeremy W. Jarrett
Jeremy W. Jarrett
AHAhmed M. Hassan
Ahmed M. Hassan
ADAndrew K Dunn
Andrew K Dunn

6 January 2016 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
EPEvan P. Perillo
Evan P. Perillo
JMJustin E. McCracken
Justin E. McCracken
DFDaniel C. Fernée
Daniel C. Fernée
JGJohn R. Goldak
John R. Goldak
FMFlor A. Medina
Flor A. Medina
ADAndrew K Dunn
Andrew K Dunn
Here we demonstrate that a mode-locked ytterbium fiber laser for two-photon fluorescence microscopy can be built for $13,000. The laser emits at a wavelength of 1060 nm with a usable average power of 1 W at a repetition rate of 40 MHz and a compressed pulse width of 81 fs at the sample. The laser is used to obtain deep in vivo two-color images of layer-V pyramidal neurons expressing YFP and vasculature labelled with Texas Red at depths up to 900 µm. The sub-1 µm features of dendritic spines can be resolved at a 200 µm depth.

7 March 2022 in Neurophotonics
Verified
Journal Article
Open access
PDF file
DMDavid R. Miller
David R. Miller
RARamsey Ashour
Ramsey Ashour
CSColin T. Sullender
Colin T. Sullender
ADAndrew K Dunn
Andrew K Dunn
Cerebral blood flow (CBF) monitoring is routine during cerebrovascular surgery to inform decision-making.1 In cerebral aneurysm clipping cases, various technologies are routinely used to confirm patency in vessels and determine successful aneurysmal obliteration. Current intraoperative tools for CBF monitoring and visualization include indocyanine green angiography (ICGA),2 – 7 Doppler8 – 10 and transit-time11,12 ultrasound, and percutaneous transfemoral digital subtraction angiography (DSA).13 – 17 ICGA records the fluorescence wash in of a bolus of indocyanine green (ICG) after intravenous injection. DSA images are acquired by obtaining multiple time-controlled x-rays as contrast medium is injected intra-arterially.

28 June 2017 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
DMDavid R. Miller
David R. Miller
AHAhmed M. Hassan
Ahmed M. Hassan
JJJeremy W. Jarrett
Jeremy W. Jarrett
FMFlor A. Medina
Flor A. Medina
EPEvan P. Perillo
Evan P. Perillo
ADAndrew K Dunn
Andrew K Dunn
We perform high-resolution, non-invasive, in vivo deep-tissue imaging of the mouse neocortex using multiphoton microscopy with a high repetition rate optical parametric amplifier laser source tunable between λ=1,100 and 1,400 nm. By combining the high repetition rate (511 kHz) and high pulse energy (400 nJ) of our amplifier laser system, we demonstrate imaging of vasculature labeled with Texas Red and Indocyanine Green, and neurons expressing tdTomato and yellow fluorescent protein. We measure the blood flow speed of a single capillary at a depth of 1.2 mm, and image vasculature to a depth of 1.53 mm with fine axial steps (5 μm) and reasonable acquisition times. The high image quality enabled analysis of vascular morphology at depths to 1.45 mm.

1 June 2015 in American Journal of Forensic Medicine & Pathology
Verified
Journal Article
Open access
DMDavid Miller
David Miller
PBPatrick Barnes
Patrick Barnes
MMMarvin Miller
Marvin Miller
Infants with the triad (neurologic dysfunction, subdural hematoma [SDH], and retinal hemorrhage) are often diagnosed as victims of shaken baby syndrome. Medical conditions/predisposing factors to developing the triad are often dismissed: short falls, birth-related SDH that enlarges, macrocephaly, sinus/cortical vein thrombosis, and others. Six infants with the triad are described in which child abuse was diagnosed, but parents denied wrongdoing. All 6 had either macrocephaly or enlarging head circumference, which suggested medical explanations. Three infants incurred short falls, 1 had a difficult delivery in which there was likely a rebleed of a birth-related SDH, 1 had a spontaneous SDH associated with increased extra-axial fluid spaces, and 1 had a sinus thrombosis. Following legal proceedings, all 6 infants were returned to their parents, and there has been no child maltreatment in follow-up, suggesting child abuse never happened. The results indicate that alternative medical explanations for causing the triad should be considered and that macrocephaly or an enlarging head circumference raises the possibility of a medical explanation.

15 January 2019 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
AHAhmed M. Hassan
Ahmed M. Hassan
XWXu Wu
Xu Wu
JJJeremy W. Jarrett
Jeremy W. Jarrett
SXShihan Xu
Shihan Xu
JYJiangbo Yu
Jiangbo Yu
ADAndrew K. Dunn
Andrew K. Dunn
Deep in vivo imaging of vasculature requires small, bright, and photostable fluorophores suitable for multiphoton microscopy (MPM). Although semiconducting polymer dots (pdots) are an emerging class of highly fluorescent contrast agents with favorable advantages for the next generation of in vivo imaging, their use for deep MPM has never before been demonstrated. Herein, we characterize the multiphoton properties of three pdot variants and perform deep in vivo MPM imaging of cortical rodent microvasculature. We find pdot brightness exceeds conventional fluorophores, including quantum dots, and their broad multiphoton absorption spectrum permits imaging at wavelengths better-suited for biological imaging and confers compatibility with a range of longer excitation wavelengths. This results in substantial improvements in signal-to-background ratio (>3.5-fold) and greater cortical imaging depths (z = 1,300 µm). Ultimately, pdots are a versatile tool for MPM due to their extraordinary brightness and broad absorption, enabling interrogation of deep structures in vivo.