Tao Shu

Tao Shu

Auto-generated profile, based on publicly available information

Tao Shu

Sun Yat Sen Univ, Affiliated Hosp 7, Dept Orthopaed, 628 Zhenyuan Rd, Shenzhen 518100, Guangdong, Peoples R China

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 June 2021 in Nanomedicine
Verified
Journal Article
Closed access
JCJiyun Cheng
Jiyun Cheng
ZCZheng Chen
Zheng Chen
CLCan Liu
Can Liu
MZMei Zhong
Mei Zhong
SWShihuan Wang
Shihuan Wang
TSTao Shu
Tao Shu
Aim: Bone mesenchymal stem cell-derived exosomes (Exos) have been shown to exert therapeutic effects in spinal cord injury (SCI). In this study, we aimed to apply bioengineering approaches to promo...

1 August 2020 in Gene
Verified
Journal Article
Closed access
LHLei He
Lei He
YCYuyong Chen
Yuyong Chen
ZKZekai Ke
Zekai Ke
MPMao Pang
Mao Pang
BYBu Yang
Bu Yang
TSTao Shu
Tao Shu

1 October 2020 in Neuroscience
Verified
Journal Article
Closed access
YCYuyong Chen
Yuyong Chen
LHLei He
Lei He
MPMao Pang
Mao Pang
ZKZekai Ke
Zekai Ke
XZXiaozuo Zheng
Xiaozuo Zheng
TSTao Shu
Tao Shu

23 December 2024 in BMC Surgery
Verified
Journal Article
Open access
JLJiachun Li
Jiachun Li
LLLujing Li
Lujing Li
YHYanqing Hu
Yanqing Hu
SHshenghui huang
shenghui huang
PCPeng Cui
Peng Cui
WLWenfen Liu
Wenfen Liu
Purpose The aim of this study was to determine whether ultrasound guidance can reduce the duration, blood loss volume and invasiveness of surgery for internal fixator removal. Methods The clinical data from 35 adults patients who underwent ultrasound-guided surgical removal of internal fixators after complete healing of limb fractures between June 2019 and April 2023 were retrospectively analysed and compared with those from 34 controls who underwent the procedure without ultrasound guidance. Data concerning the patients' demographic and clinical characteristics and surgical sites were collected. Differences in the patients' demographic and clinical characteristics were compared between the two groups. Results Sixty-nine patients were enrolled in the study. Thirty-five patients underwent surgical removal of internal fixators with ultrasound guidance, and the average intraoperative blood loss volume was 15.17 +/- 18.54 ml, average difference between the incision length and scar length was 4.24 +/- 1.38 cm, average operation time was 60.66 +/- 24.30 min, and average ultrasound assessment time was 10.00 +/- 3.90 min. Thirty-four patients underwent surgical removal of internal fixators without ultrasound guidance, and the average blood loss volume was 46.76 +/- 90.74 ml, average difference between the incision length and scar length was 2.68 +/- 1.04 cm, and average operation time was 80.15 +/- 58.84 min. The difference between the incision length and scar length was significant (P < 0.01), as was the difference in the intraoperative blood loss volume (P < 0.05) between the two groups. Conclusion Ultrasound is a convenient, noninvasive, radiation-free technique that allows dynamic scanning of multiple sections regardless of patient position. Ultrasound-assisted removal of internal fixators might reduce bleeding and therefore the invasiveness of the procedure. Physicians can use ultrasound for preoperative patient positioning, intraoperative monitoring, and postoperative confirmation of complete removal of internal fixators if necessary.