20 October 2017 in International Transactions on Electrical Energy Systems
9 September 2019 in IET Generation, Transmission & Distribution
Ensuring the efficiency and robustness of a power system stabiliser is indebted to provide a comprehensive scheme that considers significant uncertainties in variables and parameters of the model. This study proposes a robust type‐II fuzzy logic‐based power system stabiliser scheme that can handle the uncertainties in both loading condition and line parameters. Unlike loading condition, there are many lines in a typical power system and it is necessary to introduce an indicator that can mark lines with significant uncertainty in the parameters. Hence, a criterion based on Oscillatory Stability Index is presented in the study. On the other hand, random samples from line parameters and loading conditions are generated by the roulette‐wheel using probability density functions (PDF) to form the elements of the weighting matrix. Two objective functions including weighted eigenvalue deviations and damping ratios are defined and then optimised to find the parameters of the proposed stabiliser in the uncertain environment. Simulations are carried out in different scenarios and in terms of both load condition and line parameters changes. Finally, the performance of the proposed stabiliser is assessed through comparisons with an optimised lead–lag power system stabiliser and a robust lead–lag power system stabiliser.
15 December 2014 in International Transactions on Electrical Energy Systems
23 February 2021 in IET Renewable Power Generation
This study focuses on a zero voltage transition multi‐input quasi‐Z‐source converter (qZSC). This topology can be used for input sources with different voltages and currents to provide a constant output voltage. In the proposed structure, several qZSCs are combined and the output filter of all stages is eliminated. Therefore, the overall number of circuit elements, cost, volume and weight are reduced in comparison with when they are in a separate operation. In this converter, the soft‐switching conditions are provided for all stages by using only one auxiliary circuit. The employed technique provides zero‐voltage zero‐current switching (ZVZCS) and zero‐voltage switching for main switches at turn‐on and turn‐off instants, respectively. The auxiliary switch turns on under zero‐current switching and turns off under ZVZCS. Furthermore, the reverse recovery losses of diodes are reduced. The theoretical foundation of the proposed converter is presented and its performance is simulated by OrCAD software. The obtained results show 3.5% improvement in the efficiency at nominal loads, compared to its hard‐switching counterpart. A dual‐input prototype of the proposed structure is successfully built to support the validity of the theoretical analysis.
16 October 2019 in Iranian Journal of Science and Technology, Transactions of Electrical Engineering
16 November 2016 in International Transactions on Electrical Energy Systems
This article establishes a new parallel hybrid active power filter that is elaborated on the joint operation of voltage and current source converters. The idea is in fact combining a voltage source converter (VSC) and a current source converter (CSC) in parallel to form a hybrid scheme that aggregates the benefits of both converters and does not have drawbacks of each one of them. It is conceptually discussed that when low-frequency components in the reference current are conducted to the CSC and high-frequency components are devoted to the VSC, then significant reductions can be obtained in the sizes of the hybrid compensator's elements. However, the merit of the proposed scheme is dependent on separation frequency. The idea is then supported by mathematical descriptions and next validated by a series numerical simulation in Matlab/Simulink environment. The performance of the proposed hybrid scheme is successfully examined in a typical distribution network and also compared with a CSC and/or VSC alone.