Xiangkun Li

Xiangkun Li

Auto-generated profile, based on publicly available information

Xiangkun Li

Deutsches Elektronen‐Synchrotron, Zeuthen site Zeuthen Germany

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 February 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
XLX-K Li
X-K Li
ZAZ Amirkhanyan
Z Amirkhanyan
AGA Grebinyk
A Grebinyk
MGM Gross
M Gross
YKY Komar
Y Komar
FSF Stephan
F Stephan
Objective. The photo injector test facility at DESY in Zeuthen (PITZ) is building up an R&D platform, known as FLASH lab @PITZ, for systematically studying the FLASH effect in cancer treatment with its high-brightness electron beams, which can provide a uniquely large dose parameter range for radiation experiments. In this paper, we demonstrate the capabilities by experiments with a reduced parameter range on a startup beamline and study the potential performance of the full beamline by simulations. Approach. To measure the dose, Gafchromic films are installed both in front of and after the samples; Monte Carlo simulations are conducted to predict the dose distribution during beam preparation and help understand the dose distribution inside the sample. Plasmid DNA is irradiated under various doses at conventional and ultra-high dose rate (UHDR) to study the DNA damage by radiations. Start-to-end simulations are performed to verify the performance of the full beamline. Main results. On the startup beamline, reproducible irradiation has been established with optimized electron beams and the delivered dose distributions have been measured with Gafchromic films and compared to FLUKA simulations. The functionality of this setup has been further demonstrated in biochemical experiments at conventional dose rate of 0.05 Gy s−1 and UHDR of several 105 Gy s−1 and a varying dose up to 60 Gy, with the UHDR experiments finished within a single RF pulse (less than 1 millisecond); the observed conformation yields of the irradiated plasmid DNA revealed its dose-dependent radiation damage. The upgrade to the full FLASH lab @PITZ beamline is justified by simulations with homogeneous radiation fields generated by both pencil beam scanning and scattering beams. Significance. With the demonstration of UHDR irradiation and the simulated performance of the new beamline, FLASH lab @PITZ will serve as a powerful platform for studying the FLASH effects in cancer treatment.

1 May 2015 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Verified
Journal Article
Closed access
XLXiangkun Li
Xiangkun Li
MLMing Li
Ming Li
LDLijun Dan
Lijun Dan
THTianhui He
Tianhui He
YLYu Liu
Yu Liu
CTChuanxiang Tang
Chuanxiang Tang

24 August 2020
Verified
Conference Paper
Open access
KKKathleen Krah
Kathleen Krah
SESean Ericson
Sean Ericson
XLXiangkun Li
Xiangkun Li
WOWonuola Olawale
Wonuola Olawale
RCRicardo Castillo
Ricardo Castillo
Jill Engel-CoxJill Engel-Cox
Jill Engel-Cox
The oil and gas industry is increasingly seeking operational improvements to reduce both costs and emissions while improving resilience against electric grid outages. This study describes techno-economic analysis of opportunities for distributed energy generation and storage technologies to support companies’ energy cost savings, clean energy, and energy resiliency goals. Specifically, the analysis evaluates solar photovoltaics (PV), distributed wind energy, and battery energy storage at hypothetical upstream well sites in the Marcellus Shale in Pennsylvania, both grid-connected and off-grid. Results indicate opportunity for solar PV to reduce operational costs. Additionally, these technologies reduce the site’s consumption of grid electricity and natural gas and thus can help reduce Scope 1 and 2 emissions associated with electricity and natural gas consumption. For each emissions reduction scenario, a cost of avoided emissions was calculated; these values can be compared to internal organizational value placed on emissions reductions, compared to other emissions reduction strategies such as energy efficiency, reducing flaring, and direct carbon capture and sequestration, and compared to existing (albeit limited) U.S. carbon markets such as California’s Low Carbon Fuel Standard. Results indicate that the associated costs of emissions reductions via distributed renewables are competitive with these options and markets. The study also explores the ability of these electric clean energy technologies to support site resiliency against utility outages.

Verified
Conference Paper
Open access
XLXiangkun Li
Xiangkun Li
ZAZakaria Aboulbanine
Zakaria Aboulbanine
GAGowri Adhikari
Gowri Adhikari
NANamra Aftab
Namra Aftab
ZAZohrab Amirkhanyan
Zohrab Amirkhanyan
TWTobias Weilbach
Tobias Weilbach
The Photo Injector Test facility at DESY in Zeuthen (PITZ) is developing a THz SASE FEL as a prototype high repetition rate accelerator-based source for the THz-pumped, X-ray-probed experiments at the European XFEL. For the generation of THz pulses of mJ-level energy from SASE, an electron beam with a high charge (up to 4 nC) and high peak current (~200 A) will be injected into an LCLS-I undulator, which is currently being installed at the end of the photo-injector. The narrow vacuum chamber (11x5 mm) between the magnetic poles and the strong vertical focusing from the undulator, as well as the lack of beam diagnostics, have made it a challenge to match the space-charge dominated beam into the undulator without beam loss during the following transport. In this paper, boundary conditions of a matched electron beam will be discussed and the simulation and experimental study on our matching strategy will be presented.

14 September 2026 in Medical Physics
Verified
Journal Article
Open access
PDF file
RAReem Ahmad
Reem Ahmad
OAOxana Actis
Oxana Actis
AAAdam H. Aitkenhead
Adam H. Aitkenhead
RARichard A. Amos
Richard A. Amos
NBNiels Bassler
Niels Bassler
SFSamuel Flynn
Samuel Flynn
Particle minibeam therapy (PMBT) has emerged as an advanced modality within spatially fractionated radiation therapy, using the physical properties of protons, ions, and electrons to achieve superior normal tissue sparing whilst preserving spatial dose distribution at depths that are unachievable in conventional kV or MV X‐rays. As with any novel radiotherapy technique, successful translation into routine clinical practice requires robust evidence of efficacy, safety, and technical feasibility. This review presents a coordinated roadmap for the development and future implementation of PMBT, identifying the key challenges that must be addressed to enable safe and effective clinical implementation. This review highlights the interconnected nature of PMBT research and proposes the priority areas for future investigation, and the steps necessary to guide PMBT from experimental concept, towards clinical implementation. As most of the steps are relevant to all particle types, PMBT will be referred to in general, where specific particle types will be discussed where appropriate.