19 February 2025 in Physics in Medicine & Biology
Objective. The photo injector test facility at DESY in Zeuthen (PITZ) is building up an R&D platform, known as FLASH
lab
@PITZ, for systematically studying the FLASH effect in cancer treatment with its high-brightness electron beams, which can provide a uniquely large dose parameter range for radiation experiments. In this paper, we demonstrate the capabilities by experiments with a reduced parameter range on a startup beamline and study the potential performance of the full beamline by simulations. Approach. To measure the dose, Gafchromic films are installed both in front of and after the samples; Monte Carlo simulations are conducted to predict the dose distribution during beam preparation and help understand the dose distribution inside the sample. Plasmid DNA is irradiated under various doses at conventional and ultra-high dose rate (UHDR) to study the DNA damage by radiations. Start-to-end simulations are performed to verify the performance of the full beamline. Main results. On the startup beamline, reproducible irradiation has been established with optimized electron beams and the delivered dose distributions have been measured with Gafchromic films and compared to FLUKA simulations. The functionality of this setup has been further demonstrated in biochemical experiments at conventional dose rate of 0.05 Gy s−1 and UHDR of several 105 Gy s−1 and a varying dose up to 60 Gy, with the UHDR experiments finished within a single RF pulse (less than 1 millisecond); the observed conformation yields of the irradiated plasmid DNA revealed its dose-dependent radiation damage. The upgrade to the full FLASH
lab
@PITZ beamline is justified by simulations with homogeneous radiation fields generated by both pencil beam scanning and scattering beams. Significance. With the demonstration of UHDR irradiation and the simulated performance of the new beamline, FLASH
lab
@PITZ will serve as a powerful platform for studying the FLASH effects in cancer treatment.
1 May 2015 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
14 September 2026 in Medical Physics
Particle minibeam therapy (PMBT) has emerged as an advanced modality within spatially fractionated radiation therapy, using the physical properties of protons, ions, and electrons to achieve superior normal tissue sparing whilst preserving spatial dose distribution at depths that are unachievable in conventional kV or MV X‐rays. As with any novel radiotherapy technique, successful translation into routine clinical practice requires robust evidence of efficacy, safety, and technical feasibility. This review presents a coordinated roadmap for the development and future implementation of PMBT, identifying the key challenges that must be addressed to enable safe and effective clinical implementation. This review highlights the interconnected nature of PMBT research and proposes the priority areas for future investigation, and the steps necessary to guide PMBT from experimental concept, towards clinical implementation. As most of the steps are relevant to all particle types, PMBT will be referred to in general, where specific particle types will be discussed where appropriate.