X-ray free-electron lasers (FELs) are state-of-the-art scientific tools capable to study matter on the scale of atomic processes. Since the initial operation of X-ray FELs more than a decade ago, several facilities with upgraded performance have been put in operation. Here we present the first lasing results of Athos, the soft X-ray FEL beamline of SwissFEL at the Paul Scherrer Institute in Switzerland. Athos features an undulator layout based on short APPLE-X modules providing full polarisation control, interleaved with small magnetic chicanes. This versatile configuration allows for many operational modes, giving control over many FEL properties. We show, for example, a 35% reduction of the required undulator length to achieve FEL saturation with respect to standard undulator configurations. We also demonstrate the generation of more powerful pulses than the ones obtained in typical undulators. Athos represents a fundamental step forward in the design of FEL facilities, creating opportunities in FEL-based sciences.
8 August 2022 in Physical Review Accelerators and Beams
Slice energy spread is one of the key parameters in free electron laser optimizations, but its accurate measurement is not straightforward. Two recent studies from high energy (>= 100 MeV) photoinjectors at SwissFEL and European x-ray free electron laser (XFEL) have reported much higher slice energy spread than expected at their XFEL working points (200-250 pC). In this paper, a new method for measuring slice energy spread at lower beam energy (similar to 20 MeV) is proposed and demonstrated at the PhotoInjector Test facility at DESY Zeuthen, and the results for 250 pC are much lower than those measured at high energy injectors.
1 September 2021 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
Standard x-ray free-electron lasers (FELs) produce pulses with total durations of tens of femtoseconds and with time and spectral profiles consisting of multiple randomly distributed spikes. Strongly compressing an electron beam is a typical approach to produce shorter and coherent FEL pulses. We have advanced this method by starting at the injector of the FEL facility with electron beams with lower charges and shorter durations than in standard configurations. This leads to shorter electron beams with reduced energy spread after full compression and, consequently, to shorter and higher-quality FEL pulses. By operating with electron beams at the injector with charges of a few pC and rms durations of 360 fs, we show the generation of hard x-ray FEL radiation with practically all pulses having a single spike and a duration estimated from spectral measurements of about 300 as (full-width-at-half-maximum values). The demonstration was conducted at SwissFEL, the FEL at the Paul Scherrer Institute in Switzerland. Our work represents a simple way to enhance the production of single-spike events in x-ray FEL facilities, paving the way to achieve fully coherent hard x-ray FEL pulses with unprecedented durations.
27 October 2022 in Physical Review Accelerators and Beams
Photoinjectors are the main high brightness electron sources for x-ray free electron lasers (XFELs). Photoinjector emittance reduction is one of the key knobs for improving XFEL lasing, so precise emittance measurement is critical. It is well known that rms emittance is very sensitive to low intensity tails of particle distributions in the phase space, whose measurement depends on the signal to noise ratio and image processing procedures. Such sensitivities make the interpretations of beam transverse brightness challenging, leading to different emittance definitions to reduce the impact of tail particles. In this paper, transverse phase space is analyzed in action and phase coordinates for both analytical models and experiments, which gives a more intuitive way to calculate the beam core brightness.
1 January 2026 in Journal of Synchrotron Radiation
The hard X-ray beamline (Aramis) of the Swiss free-electron laser (SwissFEL) has been in user operation since the end of 2017 and its performance has been continuously monitored and enhanced over the past eight years. From the beginning, spontaneous radiation has been utilized to monitor the behavior of its 13 individual undulator modules: the pointing direction of the electron beam in each module, their alignment relative to the electron beam, and the calibration of their magnetic field strength ( K calibration). This article introduces the methods employed at the Aramis beamline to optimize performance using spontaneous radiation, traces the evolution of these improvements, and highlights the recently achieved record performance.