Special protection systems based on generator tripping are implemented to protect power systems against the loss of synchronism following extreme contingency events. Such a countermeasure is particularly effective when the circuit breakers of the tripped generators are opened soon after the fault is cleared. This paper presents the new method that enables quick real-time predictions of transient instability and the number of generators that must be tripped. The proposed method uses only local measurements and is based on the quick prediction of the magnitude of the power-angle characteristic. The proposed method has been validated by simulation tests performed for a large-scale real power system and detailed models of power system elements.
9 December 2019 in IEEE Transactions on Power Systems
This paper proposes a new event-based logic of the breaker failure protection to improve power system transient stability by shortening the total clearing time of extreme contingencies involving circuit breaker failures. Stability improvement is achieved by using dual-timer protection with shorter safety margin for multi-phase faults close to the power plant and longer safety margin for remote multi-phase faults and single-phase faults. The use of the output signal obtained for a short safety margin depends on how the substation is configured. In the breaker-and-a-half configuration, this output signal is used to speed up the opening of all adjacent circuit breakers. In substations with the dual (or triple) busbar configuration the output signal obtained with a short safety margin is used to speed up the busbar splitting. A case study was performed for a real large-scale power system. Simulation results confirmed the advantages of the proposed logic. Breaker failure protection with the proposed logic has been implemented in a substation of a large power plant.
Power system transient stability can be effectively improved by applying shunt braking resistors. This paper proposes multi-objective heuristics-based optimization for shunt braking resistor sizing. The proposed approach addresses three objectives: transient angle stability, transient voltage response, and mechanical stress of the turbine-generator shaft. The optimization problem was solved using a Python implementation of the multi-objective evolutionary NSGA-II algorithm. Based on the optimization model, comprehensive tests for multimachine IEEE 39-bus power system including single- and multi-objective simulations were performed. Pareto sets for various sets of objectives are obtained and discussed. The results show the complexity of the shunt braking resistor optimization process. Optimization studies were complemented by simulation tests performed for assessing of the impact of optimal shunt braking resistor on power system dynamic response. Detailed discussion of test results has confirmed the correctness of the proposed approach.