Bianca Ribeiro de Sales

Bianca Ribeiro de Sales

Auto-generated profile, based on publicly available information

Bianca Ribeiro de Sales

Universidade Positivo

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 August 2024 in Acta Scientiae Veterinariae
Verified
Journal Article
Open access
PDF file
TFTaíse Fuchs
Taíse Fuchs
ASAndré Saldanha
André Saldanha
GDGabriel Aikawa Dusi
Gabriel Aikawa Dusi
NMNina Da Cunha Medeiros
Nina Da Cunha Medeiros
BSBianca Ribeiro de Sales
Bianca Ribeiro de Sales
CPClaudia Turra Pimpao
Claudia Turra Pimpao
Background: Blood glucose level measurement plays an important role in the diagnosis and prognosis of different clinical conditions in rabbits. Portable glucometers offer a quick and affordable tool to measure blood glucose. However, not all commercially available glucometers are suitable for this purpose in different animal species and in different clinical conditions. This study aimed to assess the performance of 4 portable glucometers compared to a biochemical analyzer using blood samples from both healthy and sick rabbits (Oryctolagus cuniculus). Material,s Methods & Results: Blood samples were collected via jugular venipuncture from 51 rabbits. The blood glucose concentration was measured using 3 human (FO= FreeStyle Optium Neo®; AA= Accu-chek® Active; IS= Injex Sens II®) and 1 veterinarian (PGM= Wellion Vet®, Gluco Calea) glucometer, configured for dog (WD), cat (WC), and horse (WH). The results obtained from the glucometers were compared to those from the laboratory biochemical analyzer in wet biochemistry, using Spearman correlation, intraclass correlation coefficient, Bland-Altman analysis, error grid analysis and total error analysis. Blood glucose concentrations were underestimated in the human devices evaluated and overestimated in the veterinary device. Bland-Altman analysis revealed significant systematic differences in 3 of the 4 devices tested. Total error above 20% was observed in normoglycemic samples from 2 devices (FO; and PGM - WC= cat code) and in hyperglycemic samples from 1 glucometer (AA). All glucometers showed glycemic results within Zone A and B of the error grid analysis, although a glucometer (FO) present most of the results (60.8%) in Zone B. Only a single portable glucometer (IS) consistently met the objectives across all analyses. Discussion: The sample included 26 males and 25 females, with ages ranging from 5 to 96 months. Thirty-five rabbits were healthy, while 16 had various clinical abnormalities. Significant differences in median glycemia were found between the biochemical analyzer and all PGMs, except for the IS glucometer. FO and AA showed significantly lower glycemic values, while WD, WC, and WH showed higher values. The IS glucometer demonstrated the smallest mean variation and highest intraclass correlation coefficient (ICC), indicating excellent agreement. Bland-Altman plots revealed that FO and AA underestimated glycemic values, while WD, WC, and WH overestimated them. Only IS showed agreement with the laboratory analyzer. Error grid analysis indicated no serious errors with any PGMs; however, IS had over 75% of results in Zone A, showing high agreement, while FO had the least favorable results. Total error analysis suggested that only IS consistently met accuracy objectives across various analyses. The study concluded that IS was the most accurate PGM, while others showed varying degrees of inaccuracy. Although PGMs are clinically acceptable based on ISO 15197:2013 standards, accuracy and precision issues remain, particularly for euglycemic and hyperglycemic samples. Although all glucometers showed clinically acceptable results in the error grid analysis, the accuracy varied among the devices. Collectively, the IS glucometer achieved the best results in measuring blood glucose in pet rabbits, demonstrating a better accuracy and lower tendency for systematic error compared to the laboratory analyzer. Despite the lower accuracy, the other evaluated glucometers showed potential for use in rabbits when a laboratory analyzer is not available, but should be used with caution, considering the glycemic range presented. Keywords: glycemia, glycemic range, biochemical analyzer, Oryctolagus cuniculus, lagomorphs, diagnosis.

4 December 2023 in Acta Scientiae Veterinariae
Verified
Journal Article
Open access
EMEloisa Muehlbauer
Eloisa Muehlbauer
ASAndré Ferreira Saldanha
André Ferreira Saldanha
EGElaine Mayume Ueno Gil
Elaine Mayume Ueno Gil
MSMarina Silvestre Sombrio
Marina Silvestre Sombrio
BSBianca Ribeiro Sales
Bianca Ribeiro Sales
TFTilde Rodrigues Froes
Tilde Rodrigues Froes
Background: Cystocentesis is a percutaneous aspiration of urine directly from the urinary bladder. It is a routine procedure in veterinary medicine for laboratory urine evaluation and bladder decompression in dogs and cats. Although considered simple and causing minimal discomfort, it remains invasive with potential risks of complications. These complications include bladder rupture leading to abdominal contamination and peritonitis, as well as aortic and vena cava laceration, abdominal wall injuries, seizures, and syncope. There is a scarcity of epidemiological studies assessing risk factors and associated complications and, in this context, we aimed in this study to correlate risk factors with the main complications of ultrasound-guided cystocentesis in dogs and cats.Materials, Methods & Results: It was a prospective and multicentric study involving 410 animals (267 dogs and 143 cats) with clinical indications for cystocentesis. The animals were positioned in dorsal recumbency and restrained by either owner, technical staff, or both. Temperament (calm/docile or agitated/difficult to restrain), along with various data such as species, breed, weight, age, sex, needle length, number of attempts, volume of urine collected, ultrasound findings, and any complications during the procedure, were recorded. Animals were categorized into 2 groups, group with complications (GCI) and group without complications (GSI). Of these, 31 animals (8%) experienced complications after ultrasound-guided urine collection. Compared to agitated animals, there was an 86% reduction in the likelihood of complications in animals classified as calm and easy to handle. Repeated urine collection attempts increased the chance of complications by 110%, even in calm individuals, and each additional millimeter of needle length used for puncture increased the possibility of complications by 30%. Agitated animals restrained by their owner had a 71% chance of complications compared to 7% when they were restrained by the technical staff.Discussion: The data reveals a low probability of complications (8%) during cystocentesis, but it is crucial to consider the risk factors for each patient, as catastrophic outcomes can occur. Interestingly, older animals had a 14% lower likelihood of complications, likely due to increased adaptability and calmness. Proper restraint by a specialized team significantly reduced complication risks, even for agitated animals, which is a noteworthy finding not previously reported. Repeated attempts at urine collection increased complication risks, as did using longer needles, which could damage tissues and puncture vessels near the bladder. In this study, data regarding bladder filling was not included, potentially impacting the results and procedure difficulty. The absence of behavioral assessment scales to measure agitation or anxiety resulted in subjective assessments, lacking standardization. Ultrasound guidance during cystocentesis is valuable to minimize risks and should be considered. While the probability of complications is low, owners should be informed of potential risks, and sedation may be necessary for very agitated or uncooperative animals. In conclusion, ultrasound-guided cystocentesis resulted in complications in approximately 8% of cases. These complications can be significant, such as puncturing large vessels and rupturing the urinary bladder.Keywords: cystocentesis, ultrasound, canine, feline, complication, epidemiology.