Nigel P. Davies

Nigel P. Davies

Auto-generated profile, based on publicly available information

Nigel P. Davies

Imaging and Medical Physics University Hospitals Birmingham NHS Foundation Trust Birmingham UK

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 March 2015 in NMR in Biomedicine
Verified
Journal Article
Open access
Matthew Grech-SollarsMatthew Grech-Sollars
Matthew Grech-Sollars
PHPatrick W. Hales
Patrick W. Hales
KMKeiko Miyazaki
Keiko Miyazaki
FRFelix Raschke
Felix Raschke
DRDaniel Rodriguez
Daniel Rodriguez
CCChris A. Clark
Chris A. Clark
The purpose of this work was to assess the reproducibility of diffusion imaging, and in particular the apparent diffusion coefficient (ADC), intra-voxel incoherent motion (IVIM) parameters and diffusion tensor imaging (DTI) parameters, across multiple centres using clinically available protocols with limited harmonization between sequences. An ice-water phantom and nine healthy volunteers were scanned across fives centres on eight scanners (four Siemens 1.5T, four Philips 3T). The mean ADC, IVIM parameters (diffusion coefficient D and perfusion fraction f) and DTI parameters (mean diffusivity MD and fractional anisotropy FA), were measured in grey matter, white matter and specific brain sub-regions. A mixed effect model was used to measure the intra- and inter-scanner coefficient of variation (CV) for each of the five parameters. ADC, D, MD and FA had a good intra- and inter-scanner reproducibility in both grey and white matter, with a CV ranging between 1% and 7.4%; mean 2.6%. Other brain regions also showed high levels of reproducibility except for small structures such as the choroid plexus. The IVIM parameter f had a higher intra-scanner CV of 8.4% and inter-scanner CV of 24.8%. No major difference in the inter-scanner CV for ADC, D, MD and FA was observed when analysing the 1.5T and 3T scanners separately. ADC, D, MD and FA all showed good intra-scanner reproducibility, with the inter-scanner reproducibility being comparable or faring slightly worse, suggesting that using data from multiple scanners does not have an adverse effect compared with using data from the same scanner. The IVIM parameter f had a poorer inter-scanner CV when scanners of different field strengths were combined, and the parameter was also affected by the scan acquisition resolution. This study shows that the majority of diffusion MRI derived parameters are robust across 1.5T and 3T scanners and suitable for use in multi-centre clinical studies and trials.

9 July 2008 in NMR in Biomedicine
Verified
Journal Article
Open access
PDF file
NDN. P. Davies
N. P. Davies
MWMartin Wilson
Martin Wilson
LHL. M. Harris
L. M. Harris
KNK. Natarajan
K. Natarajan
SLS. Lateef
S. Lateef
APAndrew Peet
Andrew Peet
1H MRS has great potential for the clinical investigation of childhood brain tumours, but the low incidence in, and difficulties of performing trials on, children have hampered progress in this area. Most studies have used a long‐TE, thus limiting the metabolite information obtained, and multivariate analysis has been largely unexplored. Thirty‐five children with untreated cerebellar tumours (18 medulloblastomas, 12 pilocytic astrocytomas and five ependymomas) were investigated using a single‐voxel short‐TE PRESS sequence on a 1.5 T scanner. Spectra were analysed using LCModelTM to yield metabolite profiles, and key metabolite assignments were verified by comparison with high‐resolution magic‐angle‐spinning NMR of representative tumour biopsy samples. In addition to univariate metabolite comparisons, the use of multivariate classifiers was investigated. Principal component analysis was used for dimension reduction, and linear discriminant analysis was used for variable selection and classification. A bootstrap cross‐validation method suitable for estimating the true performance of classifiers in small datasets was used. The discriminant function coefficients were stable and showed that medulloblastomas were characterised by high taurine, phosphocholine and glutamate and low glutamine, astrocytomas were distinguished by low creatine and high N‐acetylaspartate, and ependymomas were differentiated by high myo‐inositol and glycerophosphocholine. The same metabolite features were seen in NMR spectra of ex vivo samples. Successful classification was achieved for glial‐cell (astrocytoma + ependymoma) versus non‐glial‐cell (medulloblastoma) tumours, with a bootstrap 0.632 + error, eB.632+, of 5.3%. For astrocytoma vs medulloblastoma and astrocytoma vs medulloblastoma vs ependymoma classification, the eB.632+ was 6.9% and 7.1%, respectively. The study showed that 1H MRS detects key differences in the metabolite profiles for the main types of childhood cerebellar tumours and that discriminant analysis of metabolite profiles is a promising tool for classification. The findings warrant confirmation by larger multi‐centre studies. Copyright © 2008 John Wiley & Sons, Ltd.

22 December 2017 in Alimentary Pharmacology & Therapeutics
Verified
Journal Article
Closed access
PDF file
PEP. J. Eddowes
P. J. Eddowes
NMN. McDonald
N. McDonald
NDN. Davies
N. Davies
SSS. I. K. Semple
S. I. K. Semple
Tim KendallTim Kendall
Tim Kendall
GHG. M. Hirschfield
G. M. Hirschfield

1 February 2013 in European Journal of Cancer
Verified
Journal Article
Closed access
JVJavier Vicente
Javier Vicente
EFElies Fuster-Garcia
Elies Fuster-Garcia
STSalvador Tortajada
Salvador Tortajada
JGJuan Miguel Garcia-Gomez
Juan Miguel Garcia-Gomez
NDNigel Davies
Nigel Davies
APAndrew Peet
Andrew Peet

16 May 2003 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
NDNigel P. Davies
Nigel P. Davies
PJPeter Jezzard
Peter Jezzard
To date, most perfusion magnetic resonance imaging (MRI) methods using arterial spin labeling (ASL) have employed slab‐selective inversion pulses or continuous labeling within a plane in order to obtain maps derived from all major blood vessels entering the brain. However, there is great potential for gaining additional information on the territories perfused by the major vessels if individual feeding arteries could be tagged. This study demonstrates noninvasive arterial perfusion territory maps obtained using two‐dimensional (2D) selective inversion pulses. This method is designated “selective ASL” (SASL). The SASL method was used to tag the major arteries below the circle of Willis. A combination of 2D selective tagging and multislice readout allows perfusion territories to be clearly visualized, with likely applications to cerebrovascular disease and stroke. Magn Reson Med 49:1133–1142, 2003.

15 June 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NMNatasha McDonald
Natasha McDonald
PEPeter J. Eddowes
Peter J. Eddowes
JHJames Hodson
James Hodson
SSScott I. K. Semple
Scott I. K. Semple
NDNigel P. Davies
Nigel P. Davies
Jonathan FallowfieldJonathan Fallowfield
Jonathan Fallowfield
LiverMultiScanis an emerging diagnostic tool using multiparametric MRI to quantify liver disease. In a two-centre prospective validation study, 161 consecutive adult patients who had clinically-indicated liver biopsies underwent contemporaneous non-contrast multiparametric MRI at 3.0 tesla (proton density fat fraction (PDFF), T1 and T2* mapping), transient elastography (TE) and Enhanced Liver Fibrosis (ELF) test. Non-invasive liver tests were correlated with gold standard histothological measures. Reproducibility of LiverMultiScanwas investigated in 22 healthy volunteers. Iron-corrected T1 (cT1), TE, and ELF demonstrated a positive correlation with hepatic collagen proportionate area (allp < 0·001). TE was superior to ELF and cT1 for predicting fibrosis stage. cT1 maintained good predictive accuracy for diagnosing significant fibrosis in cases with indeterminate ELF, but not for cases with indeterminate TE values. PDFF had high predictive accuracy for individual steatosis grades, with AUROCs ranging from 0.90–0.94. T2* mapping diagnosed iron accumulation with AUROC of 0.79 (95% CI: 0.67–0.92) and negative predictive value of 96%. LiverMultiScanshowed excellent test/re-test reliability (coefficients of variation ranging from 1.4% to 2.8% for cT1). Overall failure rates for LiverMultiScan, ELF and TE were 4.3%, 1.9% and 15%, respectively. LiverMultiScanis an emerging point-of-care diagnostic tool that is comparable with the established non-invasive tests for assessment of liver fibrosis, whilst at the same time offering a superior technical success rate and contemporaneous measurement of liver steatosis and iron accumulation.