Abdulrahman Alsanosi

Abdulrahman Alsanosi

Auto-generated profile, based on publicly available information

Abdulrahman Alsanosi

King Abdullah Ear Specialist Center (KAESC), King Saud University Medical City, King Saud University Riyadh Saudi Arabia

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2020 in Otology & Neurotology
Verified
Journal Article
Closed access
SASaad Alenzi
Saad Alenzi
TKTawfiq Khurayzi
Tawfiq Khurayzi
AAAfrah Muteb Alshalan
Afrah Muteb Alshalan
FAFida Almuhawas
Fida Almuhawas
AAAbdulrahman Alsanosi
Abdulrahman Alsanosi
Background and Objectives: Electrode migration after cochlear implantation (CI) is a rare complication that accounts for 1to 15% of all revision surgery. This study is a systematic review of the literature for investigating the knowledge and approaches to the incidence of electrode migration after CI. Methods: A systematic electronic search of the literature was carried out using PubMed, Cochrane, Virtual Health Library, Scopus and Web of Science (ISI). All original articles that reported electrode migration after CI surgery were included. The Newcastle-Ottawa Scale and CARE checklist were utilized for the assessment of the risk of bias. Descriptive data analysis was performed using SPSS software. Results: A total of 26 studies including 4,316 patients were included. Out of them, 289 patients had electrode migration following CI. To diagnose electrode migration, traditional computed tomography scan was used in 13 studies, while cone-beam computed tomography was applied in three studies. In addition, electrode migration was detected during intraoperative exploration in eight studies. The most common presenting symptom was change in sound/poor performance (n = 43) followed by pain sensation (n = 15) and facial nerve stimulation (n = 10). Cholesteatoma was the most common associated pathology (n = 10) followed by infection (n = 9) and ossification of the basal turn of the cochlea (n = 8). Conclusion: Electrode migration is a major complication of CI and could be more common than previously thought. As it may occur with or without clinical complaints, long-term follow-up through routine radiological scanning is recommended. Further studies are warranted to identify the underlying mechanism of electrode extrusion and the appropriate fixation method.

28 February 2025 in Clinical and Experimental Otorhinolaryngology
Verified
Journal Article
Open access
PDF file
SASalman F Alhabib
Salman F Alhabib
FAFarid Alzhrani
Farid Alzhrani
AAAbdulrahman Alsanosi
Abdulrahman Alsanosi
MAMariam Al-Amro
Mariam Al-Amro
AAAbdulaziz Alballaa
Abdulaziz Alballaa
FAFida Almuhawas
Fida Almuhawas
Objectives. This experimental study compared the precision and surgical outcomes of manual versus robotic electrode insertions in cochlear implantation.Methods. The study was conducted on formalin-fixed cadaveric heads, with nine senior neurotologists performing both manual and robotic insertions.Results. The results showed no statistically significant differences between the two methods in terms of insertion angle, cochlear coverage, or electrode coverage. However, the robotic method demonstrated a significantly slower and more controlled insertion speed (0.1 mm/sec) compared to manual insertion (0.66±0.31 mm/sec), which is crucial for minimizing intra-cochlear force and pressures. Although robotic insertions resulted in fewer complications such as tip fold-over or scala deviation, there were instances of incomplete insertion.Conclusion. The robotic system provided a consistent and controlled insertion process, potentially standardizing cochlear implant operations and reducing outcome variability. The study concludes that robotic-assisted insertion offers significant advantages in controlling insertion speed and consistency, supporting the continued development and clinical evaluation of robotic systems for cochlear implant surgery.

16 February 2026 in Otolaryngology–Head and Neck Surgery
Verified
Journal Article
Open access
FAFarid Alzhrani
Farid Alzhrani
AAAsma Alahmadi
Asma Alahmadi
AAAfrah Muteb Alshalan
Afrah Muteb Alshalan
YAYassin Abdelsamad
Yassin Abdelsamad
AAAbdulrahman Alsanosi
Abdulrahman Alsanosi
AHAbdulrahman Hagr
Abdulrahman Hagr
Objective: Preoperative imaging is vital for cochlear implant surgeries, aiding diagnosis, and surgical planning. This study evaluated global practices and the value of preoperative imaging through an international survey. Methods: A cross‐sectional survey was conducted among international cochlear implantation experts using a 112‐item questionnaire. The study explored imaging modalities, anatomical targets, evaluated parameters, and different imaging approaches' perceived value and risks. Participants were recruited from a global consortium of otolaryngology, otology, neurotology, and cochlear implant surgery professionals. Results: Thirty‐nine practitioners from 36 centers in 16 countries completed the survey (95.1% response rate). All used computed tomography (CT) and magnetic resonance imaging (MRI) for preoperative evaluation; MRI was deemed more valuable for diagnosis and candidacy assessment, while CT was preferred for surgical planning. Nearly half utilized additional imaging modalities, with functional MRI being the most common (20.5%). Additionally, 79.5% of respondents reported using image‐based surgical planning software. Discussion: Results show a universal reliance on CT and MRI for cochlear implant evaluations, with MRI aiding diagnosis and CT focusing on surgical planning. Advanced imaging techniques may emerge in specific clinical cases. Implications for Practice: Modern imaging practices and their potential changes can enhance protocol development and improve preoperative evaluations, ultimately boosting patient safety and outcomes in cochlear implantation.

9 July 2025 in The Journal of International Advanced Otology
Verified
Journal Article
Open access
AAAlhassan Jaban Algazlan
Alhassan Jaban Algazlan
IAIsra Aljazeeri
Isra Aljazeeri
MYMedhat Yousef
Medhat Yousef
YAYassin Abdelsamad
Yassin Abdelsamad
FAFida Almuhawas
Fida Almuhawas
AAAbdulrahman Alsanosi
Abdulrahman Alsanosi
Background: The aim of this study is to compare patients who develop facial nerve stimulation (FNS) after cochlear implantation (CI) and aremanaged with a triphasic stimulation pulse pattern (TPP) to those who do not develop FNS regarding the behavioral mapping parameters including the most comfortable loudness level (MCL) charge and amplitude, and the threshold level (THR), as well as the electrophysiological mappingparameters including phase duration (PD) and impedance level.Methods: A retrospective chart review of the patients who developed FNS at any point after device activation and were managed with TPP wascarried out. Electrophysiological and behavioral mapping parameters were retrieved from the programming software database at 3 time points:the time of implantation, the time of shift to TPP, and the last programming session. A control group with no FNS was matched randomly to evaluate any difference in the mapping parameters that could be attributed to FNS.Results: Sixteen ears with FNS were found to be eligible for inclusion in this study. These cases were matched to 16 ears in the control group.The programming was changed from biphasic pulse pattern (BPP) to TPP (time point -1) after a period of 22.37± 14.62 months. Resolution of FNSwas achieved in 14 ears (87.5%) by using TPP alone.Conclusion: The TPP mapping strategy, in addition to decreased phase duration, showed successful results in managing facial nerve stimulation while allowing an increase in the hearing level in the form of increased MCL amplitude.Cite this article as: Algazlan AJ, Aljazeeri I, Yousef M, et al. Electrophysiological and behavioral programming parameters in patients with facialnerve stimulation post-cochlear implantation. J Int Adv Otol. 2025, 21(2), 1704, doi: 10.5152/iao.2025.241704.

5 January 2026 in Acta Oto-Laryngologica
Verified
Journal Article
Closed access
SASalman F Alhabib
Salman F Alhabib
AAAfrah Muteb Alshalan
Afrah Muteb Alshalan
AHAhmed Hafez
Ahmed Hafez
MYMedhat Yousef
Medhat Yousef
FAFida Almuhawas
Fida Almuhawas
AAAbdulrahman Alsanosi
Abdulrahman Alsanosi
Children with prelingual profound sensorineural hearing loss (SNHL) and inner ear malformations (IEM), including cochleovestibular nerve anomalies, present complex and challenging cases during cochlear implantation. Intraoperative objective assessments, such as the electric auditory brainstem response (eABR), provide crucial information on auditory pathway integrity during surgery. To evaluate a novel intraoperative eABR paradigm in children with IEM and compare the findings with those from children with normal inner ear anatomy. Nineteen cochlear implant candidates (11 with IEM, 8 with normal anatomy) underwent implantation following comprehensive preoperative imaging and audiological evaluation. Under general anesthesia, intraoperative eABR was recorded using three stimulation paradigms, namely: external promontory (ePEABR), internal promontory (iPEABR), and intracochlear (iEABR). The presence, latency, amplitude, and threshold of Waves III and V were analyzed. ePEABR responses were observed in 45.5% of IEM and 37.5% of normal cases, with elevated thresholds and frequent artifacts. iPEABR responses were detected in all patients, showing consistent latency patterns. iEABR elicited robust responses in all pateints . Latencies shortened and amplitudes increased as stimulation approached the cochlear nerve. Intraoperative iPEABR is feasible and provides valuable objective information on auditory pathway function in children with IEM, supporting surgical decision-making during cochlear implantation.

30 April 2025 in Brazilian Journal of Otorhinolaryngology
Verified
Journal Article
Open access
AAAsma Alahmadi
Asma Alahmadi
FAFida Almuhawas
Fida Almuhawas
AAAfrah Muteb Alshalan
Afrah Muteb Alshalan
ISIbrahim Shami
Ibrahim Shami
EHEman HAJR
Eman HAJR
AAAbdulrahman Alsanosi
Abdulrahman Alsanosi
Preoperative imaging is crucial for proper Cochlear Implantation (CI) planning. Currently, no universally accepted guidelines for radiological evaluation existed before CI. While High-Resolution Computed Tomography (HRCT) reveals bony structures but may miss membranous labyrinthine abnormalities, it involves substantial radiation exposure. Conversely, Magnetic Resonance Imaging (MRI) allows visualization of fluid content without radiation exposure. This study aimed to assess the accuracy of automated preoperative cochlear measurements obtained from MRI compared to those extracted manually from HRCT and MRI scans. This retrospective study included 55 cochlear implant ears. Preoperative CT and MRI were evaluated using OTOPLAN® to determine the A value, B value, and Cochlear Duct Length (CDL). These measurements were performed using manual (CT and MRI) and automatic (MRI) options. Interrater reliability, concordance, and comparative analyses of the three approaches were conducted. Our findings indicated that automated MRI measurements were comparable to the manual CT and MRI assessments. No statistically significant differences were detected among the three approaches when determining the A, B, and CDL values. Automated measurements obtained from MRI showed more concordance with CT measurements than those obtained from manual MRI, suggesting that MRI-Auto assesses cochlear parameters better than manual MRI. Automated cochlear measurements using MRI were comparable to manual assessments using CT and MRI. Moreover, when assessing cochlear metrics, MRI-Auto outperformed the manual MRI workflow. Utilizing MRI-Auto planning for CI surgery can facilitate the process and minimize risks. Level 3.