Saad Alenzi

Saad Alenzi

Auto-generated profile, based on publicly available information

Saad Alenzi

Ministry of Health

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 December 2020 in Otology & Neurotology
Verified
Journal Article
Closed access
SASaad Alenzi
Saad Alenzi
TKTawfiq Khurayzi
Tawfiq Khurayzi
AAAfrah Muteb Alshalan
Afrah Muteb Alshalan
FAFida Almuhawas
Fida Almuhawas
AAAbdulrahman Alsanosi
Abdulrahman Alsanosi
Background and Objectives: Electrode migration after cochlear implantation (CI) is a rare complication that accounts for 1to 15% of all revision surgery. This study is a systematic review of the literature for investigating the knowledge and approaches to the incidence of electrode migration after CI. Methods: A systematic electronic search of the literature was carried out using PubMed, Cochrane, Virtual Health Library, Scopus and Web of Science (ISI). All original articles that reported electrode migration after CI surgery were included. The Newcastle-Ottawa Scale and CARE checklist were utilized for the assessment of the risk of bias. Descriptive data analysis was performed using SPSS software. Results: A total of 26 studies including 4,316 patients were included. Out of them, 289 patients had electrode migration following CI. To diagnose electrode migration, traditional computed tomography scan was used in 13 studies, while cone-beam computed tomography was applied in three studies. In addition, electrode migration was detected during intraoperative exploration in eight studies. The most common presenting symptom was change in sound/poor performance (n = 43) followed by pain sensation (n = 15) and facial nerve stimulation (n = 10). Cholesteatoma was the most common associated pathology (n = 10) followed by infection (n = 9) and ossification of the basal turn of the cochlea (n = 8). Conclusion: Electrode migration is a major complication of CI and could be more common than previously thought. As it may occur with or without clinical complaints, long-term follow-up through routine radiological scanning is recommended. Further studies are warranted to identify the underlying mechanism of electrode extrusion and the appropriate fixation method.

13 February 2020 in Ear, Nose & Throat Journal
Verified
Journal Article
Open access
PDF file
SASaad Alenzi
Saad Alenzi
ADAnandhan Dhanasingh
Anandhan Dhanasingh
HAHani Alanazi
Hani Alanazi
AAAbdulrahman Alsanosi
Abdulrahman Alsanosi
AHAbdulrahman Hagr
Abdulrahman Hagr
Objective: To understand the anatomical and dimensional variations of the human inner ear using 3-dimensional (3D) segmentation within the Middle East population. Design: Retrospective study. Setting: King Abdullah Ear Specialist Center (KAESC) Riyadh, Saudi Arabia. Participant: Forty computed tomography (CT) images of patients with sensorineural hearing loss who underwent cochlear implant (CI) were taken for analysis. Main outcome Measures: Three-dimensional images showing the anatomical variations of the inner ear including various pathological conditions, cochlear parameters including basal turn diameter (“A” value), “B” value which is perpendicular to “A” value, cochlear height, length, and width of the internal auditory canal (IAC), intercochlear spacing, and electrode angular insertion depth (AID). Results: Out of 40 CT image data sets, 12 had normal inner-ear anatomy (NA), 4 with enlarged vestibular aqueduct syndrome (EVAS), 8 with only 2 turns of the cochlea (2TL), 7 with incomplete partition (IP) type II, 5 with cochlear hypoplasia, 1 with common cavity, and 3 with abnormal IAC. Taking the NA, EVAS, 2TL, and the IP type II cases altogether, age of the patient had no correlation with the “A” value; however, the “A” value had a linear correlation with the “B” value. The age of the patient had an increasing logarithmic correlation with the IAC length and the intercochlear spacing. The “A” value did not have any meaningful correlation with the cochlear height. Three data sets showed asymmetric inner-ear malformation types on either side of the ears. All these 40 cases were implanted with various CI electrode array variants and the corresponding postoperative plain film X-ray images showing the electrode AID are given separately in figures. Conclusions: Three-dimensional segmentation of the inner ear from the temporal bone CT is a valuable clinical and training tool for surgeons and radiologists especially in difficult cases which will certainly help to understand the overall anatomical and dimensional variations.

1 May 2020 in Saudi Medical Journal
Verified
Journal Article
Open access
SASaad H. Alenzi
Saad H. Alenzi
RHRoa T. Halawani
Roa T. Halawani
AAAfrah M. Alshalan
Afrah M. Alshalan
SHSara A. Habis
Sara A. Habis
AAAbdulrahman A. Alsanosi
Abdulrahman A. Alsanosi
To determine whether family environment and demographic factors such as family income and education produce any significant difference in postoperative performance of cochlear implant (CI) patients. In this study, 49 participants who received cochlear implant devices at King Abdullah Ear Specialist Center, Riyadh, Saudi Arabia before the age 5 years were included. Data were collected between July 2019 and August 2019. Postoperative performance was assessed by speech intelligibility rating (SIR) and categories of auditory performance (CAP) scales. Family environment was assessed with family environment scale (FES) survey. Data of demography, average income, and maternal and paternal education were obtained through review of patient's medical files. The data obtained were analyzed using Statistical Package for Social Sciences for Mac, version 23 (IBM Corp, Armonk, NY, USA). A significant difference between the organization categories of FES (p less than 0.05) was observed in terms of postoperative CAP scores, while a significant effect of the expressiveness category on both postoperative CAP and SIR scores (p less than 0.05) was observed. The scores on both CAP and SIR scales were significantly affected by maternal education, and the scores on SIR scale were positively correlated with paternal education. This study suggests that post-procedural performance of auditory perception and speech intelligibility in CI patients is significantly related to the family environment as well as the education levels of the parents.

21 July 2022 in Ear, Nose & Throat Journal
Verified
Journal Article
Open access
SASalman F. Alhabib
Salman F. Alhabib
FAFida Almuhawas
Fida Almuhawas
AHAbdulrahman Hagr
Abdulrahman Hagr
FAFarid Alzhrani
Farid Alzhrani
NHNezar Hamed
Nezar Hamed
ADAnandhan Dhanasingh
Anandhan Dhanasingh
Objectives: To study the changes in the coiled configuration of electrode excess lead in the mastoid cavity in the cochlear implant recipients over time. Methods: Post-operative CT scans at two different appointments of fourteen patients with cochlear implants (CI) were retrospectively analyzed using a DICOM viewer software (3D-slicer). Mastoid thickness (MT) was measured in the oblique coronal plane from the round window (RW) entrance to the mastoid edge and inter-cochlear distance (ICD) was measured in the axial plane at the fundus level between two ears. 3D segmentation of the entire inner ear of both sides and coiled electrode excess lead was performed to visually compare the changes in coiled configuration between the two CT scan time points. Result: MT and ICD increased logarithmically with the patient’s age, as has been measured from both the 1st and the 2nd CT scans and a weak linear correlation between MT and ICD was observed. Growth in MT and ICT measured between the time of 1st and 2nd CT scans showed a strong linear correlation. In eight cases, changes in the electrode excess lead have been observed in the 2nd CT scan, either a change in the coiling configuration of electrode excess lead or shifted laterally toward the mastoid edge. The ICD growth between the 1st and the 2nd CT scans was >2 mm in only seven cases and all of them were children. All other six cases had no observed changes in the coiled electrode lead. In addition, the mastoid growth between the 1st and the 2nd CT scan was >2.5 mm in only 4 cases. Conclusion: Coiled configuration of electrode excess lead could change when the MT and ICD increased over time.

16 February 2021 in Cureus
Verified
Journal Article
Open access
PDF file
SASaad Alenzi
Saad Alenzi
FAFida Almuhawas
Fida Almuhawas
RHRoa Halawani
Roa Halawani
ASAbdulrahman Sanosi
Abdulrahman Sanosi
The aim of this study was to explore: 1) the average use of each device in sequentially implanted cochlear implants; 2) whether the inter-implant duration between implants produced any significant difference in the average use of the second implant; and 3) whether wearing hearing aids before the implantation of the second cochlear implant affects its average use. The study included 20 participants with bilateral Nucleus 24 implants (Cochlear Corporation, Lone Tree, CO). Data regarding various variables were extracted and then analyzed with IBM SPSS Statistics for Mac, version 23 (IBM Corp., Armonk, NY). The pediatric group included 14 subjects (average age 7.5 years) while the adult group comprised six subjects (average age 37.5 years). The average use of the second device was 0.9 hours per day more than the first in the pediatric group while it was 1.22 hours per day more in the adult group. We also divided the subjects on the basis of duration between the first and second devices and calculated the average use of each device by them. There was no significant difference (p>0.05). The average use by subjects who did and did not use hearing aids before implantation was also insignificant (p>0.05). No significant difference between the average use of the first and second implants, between the inter-implant duration of the first and second implants, the average use of the second implant, and between using hearing aids before the implantation of the second device and the average use was observed.