22 December 2022 in IEEE Sensors Journal
Piezoelectrets (or Ferroelectrets) are polarized cellular polymers exhibiting outstanding piezoelectric activity. Recently, a new manufacturing route has been introduced by combining 3D-printed elastomeric soft grids and bulk fluorinated ethylene propylene (FEP) thin films to build an artificial ferroelectret sandwich exhibiting outstanding d 33 coefficients. In this work a similar approach is taken, however, replacing the environmentally harmful fluorinated polymer FEP by eco-friendly polylactic acid (PLA). The goal of the present study is thereby threefold: 1) to investigate the temporal charge stability of PLA films charged at 25°C and 80°C, respectively, 2) to determine the stability of the piezoelectric activity when assembled as ferroelectret, and 3) to study the applicability of this easy assembled eco-friendly sensors for force myography. The surface potential of the PLA films was recorded over 180 days and showed promising stability. Because of the high flexibility of the spacer material, large piezoelectric d 33 coefficient of up to 2850 pC/N were recorded directly after charging and stabilized at about 1500 pC/N after approximately 50 days under ambient environmental conditions. The force myography was conducted using four similar ferroelectrets placed on a human forearm. The generated signal shapes and magnitudes of the sensors can be clearly distinguished from each other using simple machine learning algorithms known as Support Vector Machine (SVM) with a classification accuracy of 89.5%. This work can be regarded as a milestone for these sensors to be accepted in the field of human machine interfaces as an eco-friendly alternative to the conventional piezoelectric sensors.
1 May 2020 in The Journal of the Acoustical Society of America
Advanced acoustic levitation devices featuring flexible, lightweight, wide bandwidth, and film-like transducers based on ferroelectrets are designed and fabricated for sophisticated manipulation of particles in a simple way. Owing to the unique properties of ferroelectret films, such as high piezoelectric activity, very small acoustic impedance, a relatively large damping ratio, flexibility, a large area, and small density, the levitator reported features a wider bandwidth compared to ceramic-based levitators. The transportation of levitated particles is achieved by deformation of the film transducer, which represents a different and promising concept for this task.
1 July 2019 in IEEE Robotics and Automation Letters
In minimally invasive surgery, new flexible instruments enable safer and easier access to difficult-to-reach anatomical regions. However, their introduction into the clinical workflow requires robust replanning, because navigation errors during surgery render initially planned trajectories infeasible. Such replanning requires to regularly solve an expensive two point Boundary Value Problem (BVP) that connects the target pose of the instrument with the currently measured one. We propose a hybrid planning scheme that features both robust and safe replanning. This two step approach first solves the BVP and then transforms the result to circular arcs which fit the motion of our instruments' models. We exploit implicitly defined Bezier splines as a robust method for interpolation in the first step. A novel geometric translation of these splines then provides a convenient solution for movement along circular arcs. We consider two example applications: planning for a drilling unit in temporal bone surgery and guidewires in catheter insertion. Evaluation on real patient data of both temporal bone and aorta show that our proposed hybrid two step approach achieves on average $55\%$ higher replanning rates and provides $31\%$ larger clearance to risk structures, thus improving trajectory quality with regard to clinical safety.
19 July 2024 in IEEE Sensors Journal
Standardized fasteners such as bolts are particularly suitable for structurally integrated force measurements, as they are located directly in the force flow and therefore allow the monitoring of the overall system status in-situ via the multi-axis components of the acting forces. Available solutions are either tailored to specific applications or focus solely on measuring individual components such as the axial force. We present a sensor integrated bolt that is capable of measuring axial force and bending torques. Two cavities are designed within the bolt for the measurement and full integration of electronics, allowing for full encapsulation and autonomy of the sensor. Adjustments to the bolt, such as the cavity design, are optimized using a finite element analysis to minimize any weakening of its primary function. Losses in resilience correspond to the reduction of a strength class. The sensor incorporates three bending beams equipped with strain gauges benchmarked through a calibration setup, that demonstrates a low uncertainty of only 2.5% and the capability to decouple axial and bending loads from the sensor’s output signals. The sensor is integrated into a prototype M20 bolt by means of screwing and bonding connection. Measurements confirm a linear force transmission to the sensor with a linearity error of 1.0% for axial loading and a hysteresis error of 1.9 %. Experimental validation confirms the bolt’s capability to detect bending moments under axial pretension, thus allowing for capturing all acting forces on such bolted connections.