Edson Caoru Kitani

Edson Caoru Kitani

Auto-generated profile, based on publicly available information

Edson Caoru Kitani

Faculdade de Tecnologia de Santo André (FATEC), Brazil

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 September 2025 in IEEE Access
Verified
Journal Article
Open access
NSNouriandres Liborio Silva
Nouriandres Liborio Silva
AMAndré Mendes
André Mendes
FLFabrizio Leonardi
Fabrizio Leonardi
CSCirilo De Paula Silva
Cirilo De Paula Silva
EKEdson Caoru Kitani
Edson Caoru Kitani
RGRenato Giacomini
Renato Giacomini
This study introduces and experimentally validates an autonomous driving platform for off-road $8\times 4$ heavy-duty trucks, aimed at sugarcane harvesting operations. The system integrates a minimally invasive drive-by-wire interface for throttle, braking, and steering; a GNSS-based localization module; and a lightweight perception suite comprising a 2D LiDAR and a monocular camera. A modular ROS2-based architecture supports real-time perception, planning, and control. The platform was tested on an off-road track in Brazil across eight driving scenarios, including straight paths, curves, and obstacle avoidance at varying speeds. A spatial evaluation framework was implemented using arc-length reparameterization and KD-Tree nearest-neighbor matching to compare actual and reference trajectories. Metrics included lateral and heading RMSE, IAE, ITAE, jerk, and obstacle clearance. Results showed consistent high lateral tracking accuracy, with RMSE reaching 0.15 m in straight segments and remaining below 1.0 m in most complex scenarios. Scenario T8, involving curvature and obstacle deviation, surpassed this threshold due to increased control demands. Across 40 runs, heading RMSE remained below 10°, obstacle clearance above 1.5 m, and jerk below 0.5 m/s3. Geometrically modeled references yielded more stable heading control, while manually recorded paths resulted in smoother dynamic profiles. Statistical analysis confirmed that increased trajectory complexity degrades performance. Scenario T6 outperformed others in lateral stability, though results were statistically like T1 under simpler conditions. The platform demonstrated reliable tracking and real-time operation in scenarios representative of off-road agricultural tasks. Future work will focus on mitigating GNSS latency, improving post-obstacle recovery, and integrating sensor redundancy and adaptive planning to enhance deployment in agricultural logistics.

1 January 2026 in Sao Paulo Medical Journal
Verified
Journal Article
Open access
FRFlavio Pola dos Reis
Flavio Pola dos Reis
PGPedro Henrique Andrade Guimarães
Pedro Henrique Andrade Guimarães
MFMatheus Werner Fantato
Matheus Werner Fantato
SSSelma Ferrer da Silva
Selma Ferrer da Silva
LRLiliane Moreira Ruiz
Liliane Moreira Ruiz
PPPaulo Manuel Pêgo-Fernandes
Paulo Manuel Pêgo-Fernandes
BACKGROUND: Intermediate temperatures (10°C) better preserve mitochondrial function and extend ischemic time, which are fundamental for lung preservation during transplantation. The EMAIS-SR device was developed as a reusable, cost-effective alternative to maintain the 10°C set-point, thereby overcoming logistical and economic barriers in organ transport. OBJECTIVE: This study aimed to validate the thermal stability of the EMAIS-SR system in a swine model by evaluating the organ-cooling curve and the time spent within the target temperature range. DESIGN AND SETTING: Validation study using experimental surgery on porcine organs. METHODS: Lung blocks were harvested from two Landrace swine in independent experiments (P1, P2). The organs were placed in triple sterile packaging. Thermal stability was monitored for 48 h by using four negative temperature coefficient (NTC) thermistors (three intrapulmonary and one extrapulmonary) with data acquisition at a 0.1-s interval. Another datalogger (Hantek ® HTM208B) was used for control and validation. Thermal distribution was further characterized by infrared thermography (FLIR C3-X). RESULTS: In Experiment 1 (P1), intrapulmonary temperatures reached the predefined target range (≤ 12°C) approximately 1.4 h after lung extraction, and the mean temperature recorded in the container was 8.01 °C (standard deviation, 2.88°C). In Experiment 2 (P2), a mean temperature reduction of 6.6°C was observed, bringing the intrapulmonary temperature to the target range (≤ 12°C) within approximately 2 h post-extraction. CONCLUSION: The EMAIS-SR device effectively maintained lung-preservation temperatures within the target 8°C–12°C range over 48 h. These results demonstrate the system’s technical feasibility and its capacity to provide consistent thermal stability across intrapulmonary compartments.