Yasmen Abdel Baset

Yasmen Abdel Baset

Auto-generated profile, based on publicly available information

Yasmen Abdel Baset

Radiometry Lab, National Institute of Standards, Giza, Egypt

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2023 in Physica Scripta
Verified
Journal Article
Open access
PDF file
YBYasmen Abdel Baset
Yasmen Abdel Baset
SHSawsan Hamed
Sawsan Hamed
SRSameh Reda
Sameh Reda
HFHamed Farag
Hamed Farag
HGH A Abdel Ghany
H A Abdel Ghany
SFSamaa M Faramawy
Samaa M Faramawy
One of the significant metrics that has lately emerged as a result of climate change is the Ultraviolet Index (UVI). In this work, the authors established a standardized reference UVI radiometer at NIS, Egypt, and discussed the performance to cover the actual actinic spectrum. Selective commercial UVI radiometers based on the proposed detector's responsivity and spectral mismatch were compared to the standardized reference UVI radiometer. The result indicated that the established detector response covers the entire UV actinic spectrum (280–405 nm). Besides, the standardized reference UVI radiometer has the least spectrum mismatch value with the (CIE) spectral response, according to a comparison between it and the other detectors that have been evaluated. Furthermore, it has the highest occupied area under the CIE spectral response curve, which is about 73.8%, and has about 12% better performance. These findings support to use of the established detector as a reference standard for detecting UVI at the radiometry lab at NIS Egypt.

20 March 2023 in Physica Scripta
Verified
Journal Article
Open access
PDF file
YBYasmen Abdel Baset
Yasmen Abdel Baset
SHSawsan Hamed
Sawsan Hamed
SRSameh Reda
Sameh Reda
HFHamed Farag
Hamed Farag
HGH A Abdel Ghany
H A Abdel Ghany
SFSamaa M Faramawy
Samaa M Faramawy
The ultraviolet index UVI is a very important parameter used to inform the public about UV disadvantages . This can affect human health and lead to several issues. Many manufacturers have developed UV-index UVI radiometers based on the detection of the UV actinic spectral range. The response band of these radiometers is far from the actual actinic spectral range. This study aims to build a UVI detector of the actual actinic spectrum reaching the Earth to be used as a reference standard in the radiometry lab at NIS Egypt. The novelty of this study is the selection of a ready-manufactured sensor based on a GaP Schottky photodiode sensor to solve the defects in the present UVI radiometer and a careful selection of a short-pass filter and transmission diffuser. The calibration and measurement facilities available at NIS Egypt were used to describe the components. The designed detector response at 280–400 nm was used to capture the actual actinic spectrum. Several metrological studies were carried out in the laboratory to characterize the performance of the UVI detector, including spectral matching, angular response measurement, linearity, and spatial non-uniformity response. The results show and discuss the radiometric characterization of this detector.