Periodically testing the performance of any biological safety cabinet or other sterilization chambers is mandatory; hence, the importance of evaluating the effects of error factors on this performance arises. Until now, despite the necessity of disinfection against many microorganisms, particularly protection against the current pandemic, international standards for the manufacturing and evaluation of safety cabinets did not recommend testing the ultraviolet C performance inside these safety cabinets. The main aim of this paper is to use the sensitivity coefficient as one of the essential terms in uncertainty evaluation, to study the effect of different distances and tilt angles on the irradiance and, hence, the uniformity inside the cabinet or chamber. It was found that the homogeneity of the distribution of irradiance levels along the irradiated area was significantly affected by the distance and angle. The results obtained utilizing the sensitivity coefficient indicated that a simple increase in distance will result in a considerable loss in the irradiance value reaching around 30%. Every 5° increment in the tilt angle causes a decrement in the irradiance value by about 14% compared to the original value (0°); hence, the uniformity decreased significantly by around 45%. These effects may reflect on the sterilization performance of the cabinet as an essential process. At the end of this paper, due to the importance of considering these measurements and the effect of the two parameters on irradiance and, hence, the uniformity, the author recommends that these measurements be added to international standards for safety cabinets manufacturing and evaluation. The recommendation may help to focus more on evaluating the ultraviolet C homogeneity performance inside biosafety cabinets.

1 June 2019 in Journal of Physics: Conference Series
Verified
Conference Paper
Open access
PDF file
SRS M Reda
S M Reda
AAA A AbdElmaged
A A AbdElmaged
AMA S Monem
A S Monem
RER H El-Gebaly
R H El-Gebaly
SFSamaa M Faramawy
Samaa M Faramawy
The main purpose of this research is to evaluate irradiance levels delivered by non-conventional phototherapy devices.This evaluation can help to save energy, achieve better treatment and improves available intensive phototherapy quality in use in several hospitals in Egypt. The irradiated energy and uniformity of non-conventional phototherapy devices (n=36) were evaluated at nine hospitals in Egypt. These devices were categorized as three groups including; bilibeds with LEDs, bilibed with fluorescent lamps and bilisphere. The irradiance levels were measured using a phototherapy radiometer. The results show that the irradiance levels ranged from 20.3 to 93.1μW.cm-2.nm-1 and the LEDs bilibed devices produce average irradiance levels approximately double of those results from bilisphere with fluorescent lamps. Otherwise, the bilibed with fluorescent lamps (present about 30 % of the non-conventional phototherapy devices studied) is not adequate for intensive phototherapy. Any assessment of the irradiance energy of the phototherapy devices using a suitable calibrated sensor (radiometer) is mandatory in developing countries. The phototherapy devices that produces an adequate and accurate irradiance levels would increase the degradation rate of bilirubin in the blood and hence minimize the necessity to blood transfusion substitution. LEDs bilibeds produce sufficient electromagnetic energy for jaundice treatment. It can be used alone for intensive treatment better than the bilibed with fluorescent lamps and the bilisphere.

23 September 2022 in Asia Pacific Journal of Health Management
Verified
Journal Article
Open access
PDF file
SFSamaa M Faramawy
Samaa M Faramawy
SRSameh Reda
Sameh Reda
Light now has many applications in life and plays a vital role in therapeutic and protective fields. In the recent era, many light sources are considered for prevention, sterilization, and curing, especially with artificial lamps. Since the coronavirus pandemic appeared in 2019, the world has been interested in sterilization by light rays from a physical and applied point of view. In this work, the authors focus on definite spectral bands and their direct effects on the current COVID-19 pandemic for a prevention spreading purpose. According to the light use results, until now, the most useful method for decontamination against COVID-19 is ultraviolet C. The other spectral bands like UVA, UVB, and violet-blue show that they have a more negligible effect on the deactivation of the COVID-19 virus. The UVA and UVB help increase vitamin D in the human body, reflecting positively on the immunity system and increasing the recovery rate. The violet-blue band is helpful in decontamination against bacteria microorganisms. As for the IR band, the studies are still recent, and until now, there is no recommendation to use this band in sterilization against this pandemic. Studies continued on UV utilization because the world urgently needs industrial and domestic disinfection systems and sterilization. The other bands have another substantial practical effect on health improvement so any people can survive and overcome different diseases.

21 December 2023 in Physica Scripta
Verified
Journal Article
Open access
PDF file
YBYasmen Abdel Baset
Yasmen Abdel Baset
SHSawsan Hamed
Sawsan Hamed
SRSameh Reda
Sameh Reda
HFHamed Farag
Hamed Farag
HGH A Abdel Ghany
H A Abdel Ghany
SFSamaa M Faramawy
Samaa M Faramawy
One of the significant metrics that has lately emerged as a result of climate change is the Ultraviolet Index (UVI). In this work, the authors established a standardized reference UVI radiometer at NIS, Egypt, and discussed the performance to cover the actual actinic spectrum. Selective commercial UVI radiometers based on the proposed detector's responsivity and spectral mismatch were compared to the standardized reference UVI radiometer. The result indicated that the established detector response covers the entire UV actinic spectrum (280–405 nm). Besides, the standardized reference UVI radiometer has the least spectrum mismatch value with the (CIE) spectral response, according to a comparison between it and the other detectors that have been evaluated. Furthermore, it has the highest occupied area under the CIE spectral response curve, which is about 73.8%, and has about 12% better performance. These findings support to use of the established detector as a reference standard for detecting UVI at the radiometry lab at NIS Egypt.

3 October 2022 in IEEE Instrumentation & Measurement Magazine
Verified
Journal Article
Closed access
SFSamaa M Faramawy
Samaa M Faramawy
SRSameh M. Reda
Sameh M. Reda
The continuous need to calibrate radiometers makes us think and consider which of the utilized calibration methods provides the desired purpose with a high accuracy, high degree of stability in repeatability and reproducibility, and less estimated uncertainty value as possible. This study compares two common standard calibration methods that emerged and applied to two radiometers held in the radiometry lab at the National Institute of Standards (NIS), Giza, Egypt. The results concluded that the ND-filters method of calibration achieves the purpose of the study, exhibits more stability (STDEV 4% and 7%) and less combined uncertainty 2.7% and 9.4% for the two radiometers under test.

22 October 2020 in IEEE Instrumentation & Measurement Magazine
Verified
Journal Article
Closed access
SRSameh M. Reda
Sameh M. Reda
SFSamaa M Faramawy
Samaa M Faramawy
The differences in repeatability measurements between one operator than another will affect the accuracy, precision and hence the uncertainty of the same device measurements. To try to avoid or reduce the variation in repeatability measurements between each operator, a special automated translation stage was designed to improve the accuracy of measurements at defined positions. This automated stage was applied to measure the irradiance levels of two phototherapy luminaires as an example of an exposing cabinet. The standard regulations recommend that the irradiance level of any exposed area must be collected at specified positions. The results of using an automated stage show that there are personal errors affecting the manual repeatability measurements. Using the automated stage in collecting data, the standard deviation of repeatability decreased significantly by 87.5% for LED luminaire and 43.3% for the fluorescent lamps luminaire. Besides, the automated stage saved the time and energy of the operator in the most accurate way.