María Patino-Esteban

María Patino-Esteban

Auto-generated profile, based on publicly available information

María Patino-Esteban

Yebes Observatory, Centro de Desarrollos Tecnológicos, Instituto Geográfico Nacional, Ministerio de Transportes, Movilidad y Agenda Urbana, Cerro de la Palera s.n., 19141 Yebes, Spain

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2016 in Astronomy & Astrophysics
Verified
Journal Article
Open access
PDF file
PVP. de Vicente
P. de Vicente
VBValentin Bujarrabal
Valentin Bujarrabal
ADA. Díaz-Pulido
A. Díaz-Pulido
CAC. Albo
C. Albo
JAJavier Alcolea
Javier Alcolea
BVB. Vaquero
B. Vaquero
Aims. Observations of 28SiO v = 0J = 1–0 line emission (7-mm wavelength) from asymptotic giant branch (AGB) stars show in some cases peculiar profiles, composed of a central intense component plus a wider plateau. Very similar profiles have been observed in CO lines from some AGB stars and most post-AGB nebulae and, in these cases, they are clearly associated with the presence of conspicuous axial symmetry and bipolar dynamics. We aim to systematically study the profile shape of 28SiO v = 0J = 1–0 lines in evolved stars and to discuss the origin of the composite profile structure.Methods. We present observations of 28SiO v = 0J = 1–0 emission in 28 evolved stars, including O-rich, C-rich, and S-type Mira-type variables, OH/IR stars, semiregular long-period variables, red supergiants and one yellow hypergiant. Most objects were observed in several epochs, over a total period of time of one and a half years. The observations were performed with the 40 m radio telescope of the Instituto Geográfico Nacional (IGN) in Yebes, Spain.Results. We find that the composite core plus plateau profiles are systematically present in O-rich Miras, OH/IR stars, and red supergiants. They are also found in one S-type Mira (χ Cyg) and in two semiregular variables (X Her and RS Cnc) that are known to show axial symmetry. In the other objects, the profiles are simpler and similar to those observed in other molecular lines. The composite structure appears in the objects in which SiO emission is thought to come from the very inner circumstellar layers, prior to dust formation. The central spectral feature is found to be systematically composed of a number of narrow spikes, except for X Her and RS Cnc, in which it shows a smooth shape that is very similar to that observed in CO emission. These spikes show a significant (and mostly chaotic) time variation, while in all cases the smooth components remain constant within the uncertainties. The profile shape could come from the superposition of standard wide profiles and a group of weak maser spikes confined to the central spectral regions because of tangential amplification. Alternatively, we speculate that the very similar profiles detected in objects that are known to be conspicuously axisymmetric, such as X Her and RS Cnc, and in O-rich Mira-type stars, such as IK Tau and TX Cam, may be indicative of the systematic presence of a significant axial symmetry in the very inner circumstellar shells around AGB stars; such symmetry would be independent of the presence of weak maser effects in the central spikes.

7 June 2019 in Astronomy & Astrophysics
Verified
Journal Article
Open access
PDF file
JCJ. Cernicharo
J. Cernicharo
JGJ. D. Gallego
J. D. Gallego
JLJosé Antonio López-Pérez
José Antonio López-Pérez
FTF. Tercero
F. Tercero
ITI. Tanarro
I. Tanarro
JMJ. A. Martín-Gago
J. A. Martín-Gago
We present a new experimental set-up devoted to the study of gas phase molecules and processes using broad-band high spectral resolution rotational spectroscopy. A reactor chamber is equipped with radio receivers similar to those used by radio astronomers to search for molecular emission in space. The whole range of the Q (31.5–50 GHz) and W bands (72–116.5 GHz) is available for rotational spectroscopy observations. The receivers are equipped with 16 × 2.5 GHz fast Fourier transform spectrometers with a spectral resolution of 38.14 kHz allowing the simultaneous observation of the complete Q band and one-third of the W band. The whole W band can be observed in three settings in which the Q band is always observed. Species such as CH3CN, OCS, and SO2 are detected, together with many of their isotopologues and vibrationally excited states, in very short observing times. The system permits automatic overnight observations, and integration times as long as 2.4 × 105 s have been reached. The chamber is equipped with a radiofrequency source to produce cold plasmas, and with four ultraviolet lamps to study photochemical processes. Plasmas of CH4, N2, CH3CN, NH3, O2, and H2, among other species, have been generated and the molecular products easily identified by the rotational spectrum, and via mass spectrometry and optical spectroscopy. Finally, the rotational spectrum of the lowest energy conformer of CH3CH2NHCHO (N-ethylformamide), a molecule previously characterized in microwave rotational spectroscopy, has been measured up to 116.5 GHz, allowing the accurate determination of its rotational and distortion constants and its search in space.

10 April 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JLJosé Antonio López-Pérez
José Antonio López-Pérez
FTFélix Tercero-Martínez
Félix Tercero-Martínez
JSJosé M. Serna-Puente
José M. Serna-Puente
BVBeatriz Vaquero-Jiménez
Beatriz Vaquero-Jiménez
MPMaría Patino-Esteban
María Patino-Esteban
Jose Antonio Lopez FernandezJose Antonio Lopez Fernandez
Jose Antonio Lopez Fernandez
This paper shows a simultaneous tri-band (S: 2.2–2.7 GHz, X: 7.5–9 GHz and Ka: 28–33 GHz) low-noise cryogenic receiver for geodetic Very Long Baseline Interferometry (geo-VLBI) which has been developed at Yebes Observatory laboratories in Spain. A special feature is that the whole receiver front-end is fully coolable down to cryogenic temperatures to minimize receiver noise. It was installed in the first radio telescope of the Red Atlántica de Estaciones Geodinámicas y Espaciales (RAEGE) project, which is located in Yebes Observatory, in the frame of the VLBI Global Observing System (VGOS). After this, the receiver was borrowed by the Norwegian Mapping Autorithy (NMA) for the commissioning of two VGOS radiotelescopes in Svalbard (Norway). A second identical receiver was built for the Ishioka VGOS station of the Geospatial Information Authority (GSI) of Japan, and a third one for the second RAEGE VGOS station, located in Santa María (Açores Archipelago, Portugal). The average receiver noise temperatures are 21, 23, and 25 Kelvin and the measured antenna efficiencies are 70%, 75%, and 60% in S-band, X-band, and Ka-band, respectively.

1 October 2016
Verified
Conference Paper
Closed access
PCPablo García Carreño
Pablo García Carreño
SGSonia Garcia-Alvaro
Sonia Garcia-Alvaro
JLJosé Antonio López-Pérez
José Antonio López-Pérez
MPMaria Patino-Esteban
Maria Patino-Esteban
JSJose M. Serna
Jose M. Serna
RSRocio Sanchez-Montero
Rocio Sanchez-Montero
This paper shows the design, construction and characterization of an ultra-low noise and broad-band receiver system, to be used for geodetic very long baseline interferometry (VLBI) observations with the Spanish new 13.2 meter radiotelescopes, in the frame of the VLBI Global Observing System (VGOS). The cryogenic receiver front-end covers the frequency range 2-14 GHz in two simultaneous linear polarizations. It has an average receiver noise temperature lower than 20 Kelvin, except for those frequencies affected by radio frequency intereferences (RFI). The detected signals are sent to the back-end room using broad-band RF over fiber optic links. Then, the signals are distributed to four dual-channel frequency up/down converters, which provide the base-band signals for the digital VLBI back-ends.

16 March 2022 in Sensors
Verified
Journal Article
Open access
PDF file
PCPablo García Carreño
Pablo García Carreño
JGJavier González-García
Javier González-García
MPMaría Patino-Esteban
María Patino-Esteban
FBFrancisco J. Beltrán-Martínez
Francisco J. Beltrán-Martínez
MBMarta Bautista-Durán
Marta Bautista-Durán
JLJosé Antonio López-Pérez
José Antonio López-Pérez
This paper presents the new cable delay measurement system (CDMS) designed at Yebes Observatory (IGN, Spain), which is required for the VLBI Global Observing System (VGOS) stations. This system measures the phase difference between the 5 MHz reference signal from the hydrogen maser and the 5 MHz signal that reaches the broadband receiver through a coaxial cable, for the generation of calibration tones. As a result, the system detects the changes in the length of that coaxial cable due to temperature variations along the cable run and flexures caused by VGOS radio telescope movements. This CDMS outperforms the previous versions: firstly, it does not require a frequency counter for phase/delay measurements; secondly, it largely reduces the use of digital circuits; hence, reducing digital noise; and thirdly, it has a remotely controlled automatic calibration subsystem. The system was tested in the laboratory and in the radio telescope, and the measurements of both set-ups are shown. These measurements include the total noise, accuracy, hysteresis, and stability. The results in the radio telescope can be correlated with the different factors that affect the cable, such as temperature and flexures. The system allows to achieve an RMS noise of less than 0.5 ps, significantly improving the requirements established in VGOS. The system is currently installed in the Red Atlántica de Estaciones Geodinámicas y Espaciales (RAEGE)Yebes VGOS 13.2 m radio telescope, and will be installed in the Norwegian Mapping Authority (NMA) twin VGOS radio telescopes, in the Finnish Geospatial Research Institute (FGI) VGOS station and in the RAEGE Santa María VGOS radio telescope (Açores, Portugal).