Context. Yebes 40 m radio telescope is the main and largest observing instrument at Yebes Observatory and is devoted to very long baseline interferometry (VLBI) and single-dish observations since 2010. It has been covering frequency bands between 2 GHz and 90 GHz in discontinuous and narrow windows in most cases in order to match the current needs of the European VLBI Network (EVN) and the Global Millimeter VLBI Array (GMVA). Aims. The Nanocosmos project, a European Union-funded synergy grant, has enabled an increase in the instantaneous frequency coverage of the Yebes 40 m radio telescope, making it possible to observe many molecular transitions with single tunings in single-dish mode. This reduces the observing time and maximises the output from the telescope. Methods. We present technical specifications of the recently installed 31.5−50 GHz (Q band) and 72−90.5 GHz (W band) receivers along with the main characteristics of the telescope at these frequency ranges. We observed IRC+10216, CRL 2688, and CRL 618, which harbour a rich molecular chemistry, to demonstrate the capabilities of the new instrumentation for spectral observations in single-dish mode. Results. Our results show the high sensitivity of the telescope in the Q band. The spectrum of IRC+10126 offers an unprecedented signal-to-noise ratio for this source in this band. On the other hand, the spectrum normalised by the continuum flux towards CRL 618 in the W band demonstrates that the 40 m radio telescope produces comparable results to those from the IRAM 30 m radio telescope, although with a lower sensitivity. The new receivers fulfil one of the main goals of Nanocosmos and open up the possibility to study the spectrum of different astrophysical media with unprecedented sensitivity.
We present a new experimental set-up devoted to the study of gas phase molecules and processes using broad-band high spectral resolution rotational spectroscopy. A reactor chamber is equipped with radio receivers similar to those used by radio astronomers to search for molecular emission in space. The whole range of the Q (31.5–50 GHz) and W bands (72–116.5 GHz) is available for rotational spectroscopy observations. The receivers are equipped with 16 × 2.5 GHz fast Fourier transform spectrometers with a spectral resolution of 38.14 kHz allowing the simultaneous observation of the complete Q band and one-third of the W band. The whole W band can be observed in three settings in which the Q band is always observed. Species such as CH3CN, OCS, and SO2 are detected, together with many of their isotopologues and vibrationally excited states, in very short observing times. The system permits automatic overnight observations, and integration times as long as 2.4 × 105 s have been reached. The chamber is equipped with a radiofrequency source to produce cold plasmas, and with four ultraviolet lamps to study photochemical processes. Plasmas of CH4, N2, CH3CN, NH3, O2, and H2, among other species, have been generated and the molecular products easily identified by the rotational spectrum, and via mass spectrometry and optical spectroscopy. Finally, the rotational spectrum of the lowest energy conformer of CH3CH2NHCHO (N-ethylformamide), a molecule previously characterized in microwave rotational spectroscopy, has been measured up to 116.5 GHz, allowing the accurate determination of its rotational and distortion constants and its search in space.
This paper develops sufficient conditions for the constrained robust stabilization of continuous-time polytopic linear systems with unknown but bounded perturbations. The attractive ellipsoid method (AEM) is employed to determine a robustly controllable invariant set, known as attractive ellipsoid, such that the state trajectories of the system asymptotically converge to a small neighborhood of the origin despite the presence of non-vanishing perturbations. To solve the stabilization problem, we employ the Finsler’s lemma and derive new linear matrix inequality (LMI) conditions for robust state-feedback control design, ensuring convergence of state trajectories of the system to a minimal size ellipsoidal set. We also consider the state and control constrained problem and derive extended LMI conditions. Under certain conditions, the obtained LMIs guarantee that the attractive ellipsoid is nested inside the bigger ellipsoids imposed by the control and state constraints. Finally, we extend our AEM approach to the gain-scheduled state-feedback control problem, where the scheduling parameters governing the time-variant system are unknown in advance but can be measured in real-time. Two examples demonstrate the feasibility of the proposed AEM and its improvements over previous works.
This paper shows a simultaneous tri-band (S: 2.2–2.7 GHz, X: 7.5–9 GHz and Ka: 28–33 GHz) low-noise cryogenic receiver for geodetic Very Long Baseline Interferometry (geo-VLBI) which has been developed at Yebes Observatory laboratories in Spain. A special feature is that the whole receiver front-end is fully coolable down to cryogenic temperatures to minimize receiver noise. It was installed in the first radio telescope of the Red Atlántica de Estaciones Geodinámicas y Espaciales (RAEGE) project, which is located in Yebes Observatory, in the frame of the VLBI Global Observing System (VGOS). After this, the receiver was borrowed by the Norwegian Mapping Autorithy (NMA) for the commissioning of two VGOS radiotelescopes in Svalbard (Norway). A second identical receiver was built for the Ishioka VGOS station of the Geospatial Information Authority (GSI) of Japan, and a third one for the second RAEGE VGOS station, located in Santa María (Açores Archipelago, Portugal). The average receiver noise temperatures are 21, 23, and 25 Kelvin and the measured antenna efficiencies are 70%, 75%, and 60% in S-band, X-band, and Ka-band, respectively.
This paper shows the design, construction and characterization of an ultra-low noise and broad-band receiver system, to be used for geodetic very long baseline interferometry (VLBI) observations with the Spanish new 13.2 meter radiotelescopes, in the frame of the VLBI Global Observing System (VGOS). The cryogenic receiver front-end covers the frequency range 2-14 GHz in two simultaneous linear polarizations. It has an average receiver noise temperature lower than 20 Kelvin, except for those frequencies affected by radio frequency intereferences (RFI). The detected signals are sent to the back-end room using broad-band RF over fiber optic links. Then, the signals are distributed to four dual-channel frequency up/down converters, which provide the base-band signals for the digital VLBI back-ends.
12 April 2018 in IET Microwaves, Antennas & Propagation
An iterative technique to adjust ripple in a bandpass filter has been developed by curve‐fitting numerical data. It gives an approximate relation of ripple against filter coupling coefficients and resonator resonant frequencies instead of finding a Jacobian matrix for each individual filter, in exchange for making more iterations. Numerical examples show reasonable convergence for Chebyshev filters up to the 16th‐order, coupled quadruplets, coupled triplets and folded cross‐coupled filters. A bandpass filter for a radio telescope in Yebes, Spain is designed and measured, a tenth‐order superconducting spiral filter with 7% bandwidth, 2295 MHz centre frequency, <0.1 dB ripple and overall substrate size 30 mm × 8 mm. The 11 iterative simulations totalled 8.5 h of computer processing time.