27 January 2025 in IEEE Transactions on Biomedical Engineering
Objective: For low-field magnetic resonance imaging (MRI) in unshielded environment, existing methods have been proposed to eliminate electromagnetic interference (EMI) noise in each single radio-frequency (RF) receive coil. In the present study, we propose to use the EMI information from multiple MRI receive coils collectively in EMI denoising. Methods: The proposed method leverages the information of inter-channel correlation, including EMI detectors and RF receive coils to remove EMI noise. Calibration signals from both EMI detectors and RF receivers are concatenated to determine a de-correlation matrix, which is then used to denoise MRI signals. Results: Saline phantom and in vivo experiments demonstrated the efficacy of the proposed method in EMI elimination, showing that the proposed method outperformed advanced EMI elimination methods with up to 16.34% improvement in EMI noise removal percentage (NRP) and 1.58dB improvement in signal-to-noise ratio (SNR), along with reduced computational time. Conclusion: The proposed method effectively removes EMI noise and shows improved performance by using information from all receive coils. Significance: This method allows for the design of multi-receive coils for low-field MRI such as phased-arrays, which have the potential to enhance the performance in noise removal and improve the SNR in MRI signal acquisition.
1 October 2025 in IEEE Transactions on Artificial Intelligence
17 November 2025 in IEEE Transactions on Antennas and Propagation
Objective: This study aims to develop a flexible AirLink coil, namely a inductively coupled wireless resonant array, to enhance the signal-to-noise ratio (SNR) and parallel imaging performance for magnetic resonance imaging (MRI), when used in conjunction with commercial radiofrequency (RF) receive coils. Methods: The AirLink coil was designed as an array of 10 single-loop resonators, integrated with detuning circuits to ensure operation in the receive mode only. Electromagnetic simulations were conducted using the finite integration technique (FIT) to analyze the B1− field enhancement by a single AirLink loop. Phantom and in vivo experiments were performed to compare four reception configurations: AirLink coil + commercial array coil, commercial array coil alone, AirLink coil + body coil, and body coil alone. Evaluation metrics included SNR, noise correlation matrix, inverse g-factor map, and B1+ field map. Results: Electromagnetic simulations confirmed that the single AirLink loop enhanced the local B1− field. Phantom imaging showed that the AirLink coil, when used with a commercial array coil or a body coil, notably improved the SNR in local region. The AirLink coil had a negligible impact on the overall decoupling performance of the commercial array coil. In parallel imaging acceleration experiments, the AirLink coil demonstrated superior noise suppression in its covered regions compared to using the commercial array coil alone. In vivo imaging with the prefrontal cortex as the region of interest (ROI) showed improved imaging quality similar to phantom imaging, with stable RF transmission efficiency and no need for scanner parameter adjustments. Conclusion: The AirLink coil notably enhances SNR in ROIs while maintaining high parallel imaging performance and clinical compatibility. Its flexible design, low cost, and parameter-free adjustment features make it an efficient localized imaging optimization solution for routine MRI, with broad clinical application potential.