1 June 2009 in Trends in Biotechnology
26 May 2012 in Medical Engineering & Physics
A better understanding of the mechanisms producing the radial force in transcatheter heart valves is essential in order to reduce the reported cases of migration and atrio-ventricular block and improve the effectiveness of the treatment. This paper presents a numerical study of the different mechanisms responsible for the radial force exerted on the aortic annulus by self-expanding and balloon-expandable prostheses. The behavior of the Medtronic CoreValve (self-expanding) and the Edwards SAPIEN (balloon-expandable) devices, both of size 26, has been simulated and compared. The results indicate that, for both prostheses, the radial force may vary considerably within the recommended functional range for the valve implantation and is substantially higher at the smallest annular sizes. In particular, in the case of the self-expanding valve the radial force is essentially dependent on the diameter of the left ventricular outflow tract, while for the balloon-expandable valve the radial force produced is influenced by both the geometry and stiffness of the host tissue. The outcomes of this study provide a better insight into the phenomenon and useful information that could support the development of improved solutions.
4 April 2018 in Frontiers in Cardiovascular Medicine
During Atrial Fibrillation (AF) more than 90% of the left atrial thrombi responsible for thromboembolic events originate in the left atrial appendage (LAA), a complex small sac protruding from the left atrium (LA). Current available treatments to prevent thromboembolic events are oral anticoagulation, surgical LAA exclusion, or percutaneous LAA occlusion. However, the mechanism behind thrombus formation in the LAA is poorly understood. The aim of this work is to analyse the hemodynamic behaviour in four typical LAA morphologies - “Chicken wing”, “Cactus”, “Windsock” and “Cauliflower” - to identify potential relationships between the different shapes and the risk of thrombotic events. Computerised tomography (CT) images from four patients with no LA pathology were segmented to derive the 3D anatomical shape of LAA and LA. Computational Fluid Dynamic (CFD) analyses based on the patient-specific anatomies were carried out imposing both healthy and AF flow conditions. Velocity and shear strain rate (SSR) were analysed for all cases. Residence time in the different LAA regions was estimated with a virtual contrast agent washing out. CFD results indicate that both velocity and SSR decrease along the LAA, from the ostium to the tip, at each instant in the cardiac cycle, thus making the LAA tip more prone to fluid stagnation, and therefore to thrombus formation. Velocity and SSR also decrease from normal to AF conditions. After four cardiac cycles, the lowest washout of contrast agent was observed for the Cauliflower morphology (3.27% of residual contrast in AF), and the highest for the Windsock (0.56% of residual contrast in AF). This suggests that the former is expected to be associated with a higher risk of thrombosis, in agreement with clinical reports in the literature. The presented computational models highlight the major role played by the LAA morphology on the hemodynamics, both in normal and AF conditions, revealing the potential support that numerical analyses can provide in the stratification of patients under risk of thrombus formation, towards personalised patient care.
1 September 2009 in Acta Biomaterialia
23 July 2013 in Smart Materials and Structures
Auxetic cellular tubes are emerging as potential candidates for a number of critical devices requiring high resistance to kinking, such as angioplasty stents or annuloplasty rings. This work investigates the collapse under pure bending of auxetic tubes based on inverted hexagonal honeycombs, with the aim to identify design strategies suitable for improving their kinking response. First, the mechanical properties of the structure are determined under small deformation by means of analytical approaches, and used to verify the validity of numerical models. These are then used to simulate the tube collapse under pure bending, and identify the influence of the geometric parameters defining the structure on the phenomenon. The study indicates that the adoption of auxetic tubular structures can contribute to improving considerably the resistance to kinking, suggesting the parameters to be controlled in the design of critical applications.
1 January 2006 in Journal of Biomechanics