Scott Bradley Crowe

Scott Bradley Crowe

Auto-generated profile, based on publicly available information

Scott Bradley Crowe

Royal Brisbane and Women’s Hospital

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 June 2017 in Physica Medica
Verified
Journal Article
Closed access
ODO.L. Dancewicz
O.L. Dancewicz
SSS.R. Sylvander
S.R. Sylvander
TMT.S. Markwell
T.S. Markwell
SCS.B. Crowe
S.B. Crowe
JTJ.V. Trapp
J.V. Trapp

9 May 2014 in Australasian Physics & Engineering Sciences in Medicine
Verified
Journal Article
Closed access
PDF file
SCS. B. Crowe
S. B. Crowe
TKT. Kairn
T. Kairn
JKJ. Kenny
J. Kenny
RKR. T. Knight
R. T. Knight
BHB. Hill
B. Hill
JTJ. V. Trapp
J. V. Trapp

19 March 2014 in Medical Physics
Verified
Journal Article
Closed access
PCP. H. Charles
P. H. Charles
GCG. Cranmer‐Sargison
G. Cranmer‐Sargison
DTD. I. Thwaites
D. I. Thwaites
SCS. B. Crowe
S. B. Crowe
TKT. Kairn
T. Kairn
JTJ. V. Trapp
J. V. Trapp

12 March 2015 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
SCS B Crowe
S B Crowe
TKT Kairn
T Kairn
NMN Middlebrook
N Middlebrook
BSB Sutherland
B Sutherland
BHB Hill
B Hill
JTJ V Trapp
J V Trapp
This study aimed to provide a detailed evaluation and comparison of a range of modulated beam evaluation metrics, in terms of their correlation with QA testing results and their variation between treatment sites, for a large number of treatments. Ten metrics including the modulation index (MI), fluence map complexity, modulation complexity score (MCS), mean aperture displacement (MAD) and small aperture score (SAS) were evaluated for 546 beams from 122 intensity modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT) treatment plans targeting the anus, rectum, endometrium, brain, head and neck and prostate. The calculated sets of metrics were evaluated in terms of their relationships to each other and their correlation with the results of electronic portal imaging based quality assurance (QA) evaluations of the treatment beams. Evaluation of the MI, MAD and SAS suggested that beams used in treatments of the anus, rectum, head and neck were more complex than the prostate and brain treatment beams. Seven of the ten beam complexity metrics were found to be strongly correlated with the results from QA testing of the IMRT beams ( p < 0.00008). For example, values of SAS (with multileaf collimator apertures narrower than 10 mm defined as ‘small’) less than 0.2 also identified QA passing IMRT beams with 100% specificity. However, few of the metrics are correlated with the results from QA testing of the VMAT beams, whether they were evaluated as whole 360° arcs or as 60° sub-arcs. Select evaluation of beam complexity metrics (at least MI, MCS and SAS) is therefore recommended, as an intermediate step in the IMRT QA chain. Such evaluation may also be useful as a means of periodically reviewing VMAT planning or optimiser performance.

30 November 2014 in Medical Physics
Verified
Journal Article
Closed access
JMJohnny E. Morales
Johnny E. Morales
SCScott B. Crowe
Scott B. Crowe
RHRobin Hill
Robin Hill
NFNigel Freeman
Nigel Freeman
JTJ. V. Trapp
J. V. Trapp

13 June 2013 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PCP H Charles
P H Charles
SCS B Crowe
S B Crowe
TKT Kairn
T Kairn
RKR T Knight
R T Knight
BHB Hill
B Hill
JTJ V Trapp
J V Trapp
Due to their small collecting volume, diodes are commonly used in small field dosimetry. However, the relative sensitivity of a diode increases with decreasing small field size. Conversely, small air gaps have been shown to cause a significant decrease in the sensitivity of a detector as the field size is decreased. Therefore, this study uses Monte Carlo simulations to look at introducing air upstream to diodes such that they measure with a constant sensitivity across all field sizes in small field dosimetry. Varying thicknesses of air were introduced onto the upstream end of two commercial diodes (PTW 60016 photon diode and PTW 60017 electron diode), as well as a theoretical unenclosed silicon chip using field sizes as small as 5 mm × 5 mm. The metric D(w,Q)/D(Det,Q) used in this study represents the ratio of the dose to a point of water to the dose to the diode active volume, for a particular field size and location. The optimal thickness of air required to provide a constant sensitivity across all small field sizes was found by plotting D(w,Q)/D(Det,Q) as a function of introduced air gap size for various field sizes, and finding the intersection point of these plots. That is, the point at which D(w,Q)/D(Det,Q) was constant for all field sizes was found. The optimal thickness of air was calculated to be 3.3, 1.15 and 0.10 mm for the photon diode, electron diode and unenclosed silicon chip, respectively. The variation in these results was due to the different design of each detector. When calculated with the new diode design incorporating the upstream air gap, k(f(clin),f(msr))(Q(clin),Q(msr)) was equal to unity to within statistical uncertainty (0.5%) for all three diodes. Cross-axis profile measurements were also improved with the new detector design. The upstream air gap could be implanted on the commercial diodes via a cap consisting of the air cavity surrounded by water equivalent material. The results for the unclosed silicon chip show that an ideal small field dosimetry diode could be created by using a silicon chip with a small amount of air above it.