For solar photovoltaic (PV) systems, an upgraded triple gain seven-level inverter that works both independently and while connected to the grid is proposed. The two-stage configuration of the system is boost cascaded. The first stage has a one switch improved gain converter (OSIGC) to increase and normalize the input direct current (DC) voltage, and the second stage includes a unique seven level alternating current (AC) is produced via a multilevel inverter (MLI) design with triple voltage gain. The proposed OSIGC is appropriate for a broad range of conversions. The voltage gain in MLI was achieved using switched capacitor techniques. The DC-DC converter can achieve a maximum voltage gain of twelve and the MLI can achieve a maximum voltage gain of three, resulting in a DC-DC-AC voltage that can reach 36. Maximum power point tracking (MPPT) technique based on modified perturb and observe (PO) is used in OSIGC to maximise PV module power utilisation, and MLI control utilises sinusoidal pulse width modulation (SPWM) realistically. For the purpose of analysing the suggested system, a 200 Watt prototype statel is created. With a total harmonic distortion (THD) of 0.181%, up to 92.12% of the converter system’s overall efficiency is possible.
This paper presents the implementation of space vector pulse width modulation (SVPWM) for a three-phase voltage source inverter (VSI). SVPWM is a technique used to control the output voltage of VSIs with improved efficiency and precision. The abstract outlines the key steps involved in implementing SVPWM, including reference signal clarification, sector identification, determination of voltage vectors, and switching state calculation. This proposed system provides improved output voltage of the inverter, minimized voltage stress across the switches and reduced total harmonic distortion and electromagnetic interference. The proposed implementation aims to enhance the performance of three-phase VSIs in various applications, such as motor drives, renewable energy systems, and power converters. The simulation results of proposed system are verified using MATLAB Simulink.
1 December 2022 in International Journal of Power Electronics and Drive Systems (IJPEDS)
A novel matrix converter has been developed for 3-phase to 5-phase conversion using a novel space vector pulse width modulation. The matrix converter organized to generate 5-phase AC output voltage from 3-phase input voltage with help of SVPWM method; bidirectional power switches placed in matrix converter controlled by appropriate switching pulse. Space vector pulse width modulation (SVPWM) provides better utilization of applied input voltage, improved output voltage, reduced total harmonic distortion. The bidirectional switch used by the matrix converter decreases stress on the power switch and the influence of harmonic fluctuation in AC output voltage. When compared to traditional approaches, the suggested system offers improved output voltage and current control. Using MATLAB/Simulink and FPGA-cyclone controller, respectively, modelling and experimental results have been given to validate the proposed methodology.
1 December 2023 in Indonesian Journal of Electrical Engineering and Computer Science
In this study, a 27-levelinverter with a reduced switch asymmetrical cascaded H-bridge (CHB) with fuzzy logic controller (FLC) is proposed. With series connections, a low voltage converter, a middle level voltage converter, and a high voltage converter make up the static synchronous compensator (STATCOM). The configuration of the asymmetrical inverter uses trinary DCsources. To acquire switching signals for the trinary inverter-based STATCOM to compensate for real power, load voltage, reactive power, load current, and power factor under load changing conditions, FLC is constructed. With fewer switches, the suggested arrangement produces greater voltage levels. The performance of the reduced switch asymmetrical cascaded H-bridge inverter-STATCOM with FLCis simulated using the MATLAB Simulink platform under both static and dynamic load conditions. When compared to reduced switch asymmetrical cascaded H-bridge inverter-STATCOM with traditional proportional integral (PI) controller, the FLC result demonstrates efficient unbalanced load compensation. The FLC in the proposed inverter also lowers the total harmonic distortion.