Claudia Alessandra Manetti

Claudia Alessandra Manetti

Auto-generated profile, based on publicly available information

Claudia Alessandra Manetti

Department of Biomedical Engineering, CARIM School for Cardiovascular Diseases, Maastricht University Medical Center , Universiteitssingel 40, 6229 ERMaastricht

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 August 2024 in IEEE Access
Verified
Journal Article
Open access
NBNitin Burman
Nitin Burman
CMClaudia Alessandra Manetti
Claudia Alessandra Manetti
SHSophie Heymans
Sophie Heymans
MIMarcus Ingram
Marcus Ingram
JLJoost Lumens
Joost Lumens
JDJan D'hooge
Jan D'hooge
Cardiac ultrasound imaging is widely used in the clinical setting. Deep learning algorithms have shown increased potential in automating routine clinical tasks for improved diagnosis and prognosis. However, the lack of large and diverse training databases hinders their employment on a full scale in clinics. Difficulties associated with creating large training databases include scarcity of clinical data, privacy related data access concerns and labor-intensive ground-truth annotations. To overcome these issues, realistic cardiac ultrasound simulation is considered advantageous. Nevertheless, our state-of-the-art cardiac ultrasound simulation pipeline is limited to small-scale databases particularly because of the underlying computationally complex finite-element heart model. In this paper, we developed a realistic simulation pipeline to facilitate large-scale synthetic cardiac ultrasound datasets. This pipeline utilizes a well-validated and computationally efficient lump-parameter heart model for generating cardiovascular mechanics, and the convolution based ultrasound simulator COLE for short simulation times. We implemented the proposed pipeline to create a large open-access database of 2-D realistic cardiac ultrasound recordings with diversity in the geometries, ultrasound speckle texture and motions of the left ventricle. Quantitative assessment of the simulated data demonstrated that the synthetic cardiac ultrasound frames contained realistic speckle patterns. Moreover, the left ventricular motion in the simulated frames was tracked using the medical imaging tracking toolbox and was shown to closely match the kinematically imposed ground-truth left ventricular motion. The presented pipeline is valuable for creating large and diverse ground-truth training databases. The resulting database is a potential augmentation tool for machine learning-based ultrasound data processing algorithms and made publicly available.

28 March 2025 in EP Europace
Verified
Journal Article
Open access
CMClaudia A Manetti
Claudia A Manetti
NONick van Osta
Nick van Osta
ABAhmed Beela
Ahmed Beela
LHLieven Herbots
Lieven Herbots
FPF.W. W. Prinzen
F.W. W. Prinzen
JLJoost Lumens
Joost Lumens
Aims: Previous studies have not examined the role of non-electrical myocardial disease substrates in determining the optimal atrio-ventricular delay (AVD) settings. We conducted virtual patient simulations to evaluate whether myocardial disease substrates influence the acute response to AVD optimization at rest and during exercise. Methods and results: The CircAdapt cardiovascular model was used to simulate various left ventricular (LV) remodelling found in cardiac resynchronization therapy candidates. We simulated electrical dyssynchrony, LV dilatation with preserved and reduced contractility, and increased LV passive stiffness. We simulated cardiac resynchronization following biventricular (BiVP) and non-selective LBB pacing (nsLBBP). The paced-AVD ranged from 220 to 40 ms. Cardiac output and heart rate were increased to simulate different levels of exercise. The optimal AVD was the one leading to the highest stroke volume (SV) and the lowest mean left atrial pressure (mLAP). At rest, in simulations with healthy myocardium the gain in SV by AVD optimization was larger compared to those with reduced contractility and stiff myocardium. However, mLAP was comparably decreased by AVD optimization in both healthy and diseased myocardium. During exercise, the optimal AVD shifted to shorter values, and mLAP was more sensitive to AVD, particularly in the presence of hypo-contractile and stiff myocardium. Conclusion: Simulations show that hypocontractility and stiffness reduce the effect of AVD optimization on SV but enhance its benefit in lowering mLAP. Notably, virtual patients with stiff ventricles experience greater benefits from AVD optimization during exercise compared to resting conditions. Furthermore, nsLBBP provides more favourable improvements in mLAP than BiVP.

8 November 2024 in European Heart Journal - Cardiovascular Imaging
Verified
Journal Article
Open access
ABAhmed Beela
Ahmed Beela
CMClaudia A Manetti
Claudia A Manetti
FPFrits W Prinzen
Frits W Prinzen
Tammo DelhaasTammo Delhaas
Tammo Delhaas
LHLieven Herbots
Lieven Herbots
JLJoost Lumens
Joost Lumens
Aims: Both left ventricular (LV) mechanical dyssynchrony and filling pressure have been shown to be associated with outcome in heart failure patient treated with cardiac resynchronisation therapy (CRT). To investigate the mechanistic link between mechanical dyssynchrony and filling pressure and to assess their combined prognostic value in CRT candidates. Methods and results: Left atrial pressure (LAP) estimation and quantification of mechanical dyssynchrony were retrospectively performed in 219 CRT patients using echocardiography. LAP was elevated (eLAP) in 49% of the population, normal (nLAP) in 40%, and indeterminate in 11%. CRT response was defined as per cent-decrease in LV end-systolic volume after 12 ± 6 months CRT. Clinical endpoint was all-cause mortality during 4.8 years (interquartile range: 2.7–6.0 years). To investigate the mechanistic link between mechanical dyssynchrony and filling pressure, the CircAdapt computer model was used to simulate cardiac mechanics and haemodynamics in virtual hearts with left bundle branch block (LBBB) and various causes of increased filling pressure. Patients with nLAP had more significant mechanical dyssynchrony than those with eLAP. The combined assessment of both parameters before CRT was significantly associated with reverse LV remodelling and post-CRT survival. Simulations revealed that mechanical dyssynchrony is attenuated by increased LV operational chamber stiffness, regardless of whether it is caused by passive or active factors, explaining the link between mechanical dyssynchrony and filling pressure. Conclusion: Our combined clinical-computational data demonstrate that in patients with LBBB, the presence of mechanical dyssynchrony indicates relatively normal LV compliance and low filling pressure, which may explain their strong association with positive outcomes after CRT.

12 November 2026 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Closed access
CMClaudia A. Manetti
Claudia A. Manetti
TLTim van Loon
Tim van Loon
ABAhmed Beela
Ahmed Beela
WHWouter Huberts
Wouter Huberts
LHLieven Herbots
Lieven Herbots
NONick van Osta
Nick van Osta