Mélanie Audoin

Mélanie Audoin

Auto-generated profile, based on publicly available information

Mélanie Audoin

MEMS Applied Sensors Group, Department of Health Technology, Technical University of Denmark, Kongens Lyngby, Denmark

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 October 2023 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
MAMélanie Audoin
Mélanie Audoin
ASAli Salari
Ali Salari
BTBorislav Gueorguiev Tomov
Borislav Gueorguiev Tomov
KPKasper Fløng Pedersen
Kasper Fløng Pedersen
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
ETErik Vilain Thomsen
Erik Vilain Thomsen
Spherical diverging acoustic lenses mounted on flat 2D Row-Column Addressed (RCA) ultrasound transducers have shown the potential to extend the Field of View (FOV) from a rectilinear to a curvilinear volume region and thereby enable 3D imaging of large organs. Such lenses are usually designed for small aperture low-frequency transducers, which have limited resolution. Moreover, they are made of off-the-shelf pieces of materials, which leaves no room for optimization. We hypothesize that acoustic lenses can be designed to fit high-resolution transducers and they can be fabricated in a fast, cost-effective, and flexible manner using a combination of 3D printing and casting or CNC machining techniques. These lenses should increase the FOV of the array while preserving the image quality. In this work, such lenses are made in concave, convex, and compound spherical shapes, and from thermoplastics and thermosetting polymers. Polymethylpentene (TPX), Polystyrene (PS), Polypropylene (PP), Polymethyl methacrylate (PMMA), Polydimethylsiloxane (PDMS) and Room-temperature-vulcanizing silicone (RTV) diverging lenses have been fabricated and mounted on a 128+128 6 MHz RCA transducer. The performances of the lenses have been assessed and compared in terms of FOV, Signal to Noise Ratio (SNR), bandwidth, and potential artefacts. The largest FOV (24.0°) is obtained with a 42.64 mm radius PMMA-RTV compound lens, which maintains a decent fractional bandwidth (53%) and SNR at 6 MHz (-9.1 dB amplitude drop compared to the unlensed transducer). The simple PMMA TPX, PS, PP, PDMS and RTV lenses provide a FOV of 12.2°, 6.3°, 8.1°, 11.7°, 0.6° and 10.4°, a fractional bandwidth of 97%, 46%, 103%, 46%, 97%, 53% and 49%, and an amplitude drop of -5.2 dB, -4.4 dB, -2.8 dB, -15.4 dB, -6.0 dB and -1.8 dB respectively. This work demonstrates that thermoplastics are suitable materials for fabricating low-attenuation convex diverging lenses for large-aperture, high-frequency 2D transducers. This is highly desired to achieve high-resolution volumetric imaging of large organs.

6 January 2025 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
ASAli Salari
Ali Salari
MAMélanie Audoin
Mélanie Audoin
BTBorislav Gueorguiev Tomov
Borislav Gueorguiev Tomov
BYBilly Y. S. Yiu
Billy Y. S. Yiu
ETErik Vilain Thomsen
Erik Vilain Thomsen
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
Row-column (RC) arrays typically suffer from a limited field of view (FOV), with the imaging area confined to a rectangular region equal to the footprint of the probe. This limitation can be solved by using a diverging lens in front of the probe. Previous studies have introduced a Thin Lens model for beamforming lensed RC arrays, but this model inaccurately assumes the lens to be infinitely thin, leading to degraded resolution and contrast due to errors in the time of flight (TOF) calculations. This paper presents a beamformer based on ray tracing for accurate TOF calculation. A Verasonics Vantage 256 scanner was equipped with a Vermon RC probe with 128 + 128 elements, λ pitch, and a 6 MHz center frequency. A synthetic aperture ultrasound sequence with 96 virtual sources and 32 active elements for each emission with row elements was employed, and all column elements were used for acquiring data. This method was tested with a polystyrene (PS) lens with a spherical shape and polymethyl methacrylate (PMMA) in a Bicylindrical shape. Based on pressure field measurements, these two lenses provide a 20° and 33° FOV, respectively. The Thin Lens model had a lateral resolution of around 17.4λ for the Bicylindrical lens, whereas the new method achieves a resolution of around 3.8λ, representing a 4.6-fold improvement. The contrast is enhanced from 23.1 to 29.8 dB for the Bicylindrical lens while preserving the FOV.

5 April 2022 in bioRxiv
Verified
Preprint
Open access
PDF file
MAMelanie Audoin
Melanie Audoin
MSMaria Tangen Søgaard
Maria Tangen Søgaard
LJLiselotte Jauffred
Liselotte Jauffred
Glioblastoma brain tumors form in brains’ white matter and remains one of the most lethal cancers despite intensive therapy and surgery. The complex morphology of these tumors includes infiltrative growth and gain of cell motility. Therefore, various brain-mimetic model systems have been developed to investigate invasion dynamics. Despite this, exactly how gradients of cell density, chemical signals and metabolites influence individual cells’ migratory behavior remains elusive. Here we show that the gradient field – induced by the spheroid – accelerates cells’ invasion of the extracellular matrix. We show that cells are pushed away from the spheroid along a radial gradient, as predicted by a biased persistent random walk (BPRW). Thus, our results grasp in a simple model the complex behavior of metastasizing cells. We anticipate that this well-defined and quantitative assay could be instrumental in the development of new anti-cancer strategies.

16 February 2026 in IEEE Transactions on Ultrasonics
Verified
Journal Article
Closed access
MAMélanie Audoin
Mélanie Audoin
ASAli Salari
Ali Salari
RGRune Sixten Grass
Rune Sixten Grass
KSKitty Steenberg
Kitty Steenberg
KPKasper Fløng Pedersen
Kasper Fløng Pedersen
JJJørgen Arendt Jensen
Jørgen Arendt Jensen
Medical ultrasound probes commonly employ a polymer encapsulation over the transducer for electrical protection and acoustic impedance matching. However, the speed of sound mismatch between the encapsulant and biological tissue can introduce Time Of Flight (TOF) errors that degrade beamforming coherence. This article presents a beamforming method that includes the encapsulating layer in the TOF calculation to improve image quality. Two TOF approximations, Direct Path (DP) and Normal Path (NP), are evaluated in terms of accuracy and computational cost. These are compared against the Homogeneous Direct Path (HDP) model, which neglects the encapsulant, and the exact Snell’s law Path (SP), computed using ray-tracing. Simulations and experiments are performed on a silicone encapsulated Row-Column Addressed (RCA) Capacitive Micromachined Ultrasound Transducer (CMUT) probe as a case study. DP and NP increased the processing time by only 1.2 × compared to HDP, while SP increased it by 46 ×. The measured standard deviation of the TOF error was reduced from 0.10 λ (HDP) to 0.06 λ (DP), and 0.05 λ (SP), ensuring high inter-channel coherence. Lateral resolution increased up to +47%, and contrast was enhanced by ≥ +2.1 dB using DP and SP models compared to HDP. The DP approximation achieved near-SP image quality, while maintaining HDP-level computational efficiency. The validity domain of NP and DP for any transducer was generalized using a critical F-number α. Overall, the proposed approximations provide a computationally efficient means to enhance resolution and contrast, establishing a practical solution for high-resolution realtime imaging.

1 January 2026 in IEEE Transactions on Ultrasonics
Verified
Journal Article
Closed access
ASAli Salari
Ali Salari
MAMélanie Audoin
Mélanie Audoin
ARAndre Rath
Andre Rath
ETErik Vilain Thomsen
Erik Vilain Thomsen
JJJørgen Arendt Jensen
Jørgen Arendt Jensen