Gail F. Forrest

Gail F. Forrest

Auto-generated profile, based on publicly available information

Gail F. Forrest

Kessler Foundation, West Orange, NJ 07052, USA

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
GFGail F. Forrest
Gail F. Forrest
KHKaren Hutchinson
Karen Hutchinson
DLDouglas J. Lorenz
Douglas J. Lorenz
JBJeffrey J. Buehner
Jeffrey J. Buehner
LVLeslie R. VanHiel
Leslie R. VanHiel
DBD. Michele Basso
D. Michele Basso
To evaluate the relationship and redundancy between gait speeds measured by the 10 Meter Walk Test (10MWT) and 6 Minute Walk Test (6MWT) after motor incomplete spinal cord injury (iSCI). To identify gait speed thresholds supporting functional ambulation as measured with the Spinal Cord Injury Functional Ambulation Inventory (SCI-FAI). Prospective observational cohort. Seven outpatient rehabilitation centers from the Christopher and Dana Reeve Foundation NeuroRecovery Network (NRN). 249 NRN patients with American Spinal Injury Association Impairment Scale (AIS) level C (n = 20), D (n = 179) and (n = 50) iSCI not AIS evaluated, from February 2008 through April 2011. Locomotor training using body weight support and walking on a treadmill, overground and home/community practice. 10MWT and 6MWT collected at enrollment, approximately every 20 sessions, and upon discharge. The 10MWT and 6MWT speeds were highly correlated and the 10MWT speeds were generally faster. However, the predicted 6MWT gait speed from the 10MWT, revealed increasing error with increased gait speed. Regression lines remained significantly different from lines of agreement, when the group was divided into fast (≥0.44 m/s) and slow walkers (<0.44 m/s). Significant differences between 6MWT and 10MWT gait speeds were observed across SCI-FAI walking mobility categories (Wilcoxon sign rank test p<.001), and mean speed thresholds for limited community ambulation differed for each measure. The smallest real difference for the 6MWT and 10MWT, as well as the minimally clinically important difference (MCID) values, were also distinct for the two tests. While the speeds were correlated between the 6MWT and 10MWT, redundancy in the tests using predictive modeling was not observed. Different speed thresholds and separate MCIDs were defined for community ambulation for each test.

31 December 2020 in IEEE Transactions on Neural Systems and Rehabilitation Engineering
Verified
Journal Article
Open access
FZFan Zhang
Fan Zhang
KMKamyar Momeni
Kamyar Momeni
ARArvind Ramanujam
Arvind Ramanujam
MRManikandan Ravi
Manikandan Ravi
JCJanelle Carnahan
Janelle Carnahan
GFGail F. Forrest
Gail F. Forrest
Recovery of the upper extremity (UE) and hand function is considered the highest priority for people with tetraplegia, because these functions closely integrate with their activities of daily living. Spinal cord transcutaneous stimulation (scTS) has great potential to facilitate functional restoration of paralyzed limbs by neuro-modulating the excitability of the spinal network. Recently, this approach has been demonstrated effective in improving UE function in people with motor complete and incomplete cervical SCI. However, the research thus far is limited by the lack of a comprehensive assessment of functional improvement and neurological recovery throughout the intervention. The goal of this study was to investigate whether scTS can also facilitate UE functional restoration in an individual with motor and sensory complete tetraplegia. A 38-year-old male with a C5 level, ASIA Impairment Scale-A SCI (15 years post-injury, left hand dominant pre- and post-injury), received 18 sessions (60 minutes/session) of scTS combined with task-specific hand training over the course of 8 weeks. The total score of the Graded Redefined Assessment of Strength, Sensibility, and Prehension significantly improved from 72/232 to 96/232 at post-intervention, and maintained ranging from 82/232 to 86/232 during the three months follow-up without any further treatment. The bilateral handgrip force improved by 283.4% (left) and 30.7% (right), respectively at post-intervention. These strength gains were sustained at 233.5% -250% (left) and 11.5% -73.1% (right) during the follow-up evaluation visits. Neuromuscular Recovery Scale demonstrated dramatic and long-lasting improvements following the completion of the intervention. Changes of spinal motor evoked potentials from pre- to post-intervention indicated an increased level of spinal network excitability. The present data offer preliminary evidence that the novel scTS intervention combined with hand training can enhance UE functional use in people with motor and sensory complete SCI.

1 September 2012 in Archives of Physical Medicine and Rehabilitation
Verified
Journal Article
Closed access
PDF file
GFGail F. Forrest
Gail F. Forrest
DLDouglas J. Lorenz
Douglas J. Lorenz
KHKaren Hutchinson
Karen Hutchinson
LVLeslie R. VanHiel
Leslie R. VanHiel
DBD. Michele Basso
D. Michele Basso
SHSusan J. Harkema
Susan J. Harkema

20 April 2017 in The Journal of Spinal Cord Medicine
Verified
Journal Article
Closed access
ARArvind Ramanujam
Arvind Ramanujam
CCChristopher M. Cirnigliaro
Christopher M. Cirnigliaro
EGErica Garbarini
Erica Garbarini
PAPierre Asselin
Pierre Asselin
Rakesh PilkarRakesh Pilkar
Rakesh Pilkar
GFGail F. Forrest
Gail F. Forrest
Objective: To evaluate gait parameters and neuromuscular profiles of exoskeleton-assisted walking under Max Assist condition during a single-session for; (i) able bodied (AB) individuals walking assisted with (EXO) and without (non-EXO) a powered exoskeleton, (ii) non-ambulatory SCI individuals walking assisted with a powered exoskeleton. Design: Single-session. Setting: Motion analysis laboratory. Participants: Four AB individuals and four individuals with SCI. Interventions: Powered lower extremity exoskeleton. Outcome Measures: Temporal-spatial parameters, kinematics, walking velocity and electromyography data. Results: AB individuals in exoskeleton showed greater stance time and a significant reduction in walking velocity (P < 0.05) compared to non-EXO walking. Interestingly, when the AB individuals voluntarily assisted the exoskeleton movements, they walked with an increased velocity and lowered stance time to resemble that of slow walking. For SCI individuals, mean percent stance time was higher and walking velocity was lower compared to all AB walking conditions (P < 0.05). There was muscle activation in several lower limb muscles for SCI group. For AB individuals, there were similarities among EXO and non-EXO walking conditions however there were differences in several lower limb EMGs for phasing of muscle activation. Conclusion: The data suggests that our AB individuals experienced reduction in walking velocity and muscle activation amplitudes while walking in the exoskeleton and moreover with voluntary control there is a greater temporal-spatial response of the lower limbs. Also, there are neuromuscular phasic adaptions for both AB and SCI groups while walking in the exoskeleton that are inconsistent to non-EXO gait muscle activation.

11 September 2020 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
DKDominique Kinnett-Hopkins
Dominique Kinnett-Hopkins
CMChaithanya K. Mummidisetty
Chaithanya K. Mummidisetty
LELinda Ehrlich-Jones
Linda Ehrlich-Jones
DCDeborah Crown
Deborah Crown
RBRachel A. Bond
Rachel A. Bond
AHAllen Walter Heinemann
Allen Walter Heinemann
Background: Persons with spinal cord injury (SCI) may experience both psychological and physiological benefits from robotic locomotor exoskeleton use, and knowledgeable users may have valuable perspectives to inform future development. The objective of this study is to gain insight into the experiences, perspectives, concerns, and suggestions on the use of robotic locomotor exoskeletons by civilians and veterans living with SCI. Methods: Participants reported their demographic characteristics and the extent of robotic exoskeleton use in an online survey. Then, 28 experienced robotic locomotor exoskeleton users participated in focus groups held at three regional hospitals that specialize in rehabilitation for persons with SCI. We used a qualitative description approach analysis to analyze the data, and included thematic analysis. Results: Participants expressed that robotic exoskeletons were useful in therapy settings but, in their current form, were not practical for activities of daily living due to device limitations. Participants detailed the psychological benefits of being eye-level with their non-disabled peers and family members, and some reported physiologic improvements in areas such as bowel and bladder function. Participants detailed barriers of increased fatigue, spasticity, and spasms and expressed dissatisfaction with the devices due to an inability to use them independently and safely. Participants provided suggestions to manufacturers for technology improvements. Conclusions: The varied opinions and insights of robotic locomotor exoskeletons users with SCI add to our knowledge of device benefits and limitations.

17 September 2024 in Journal of Neurotrauma
Verified
Journal Article
Closed access
GSGoutam Singh
Goutam Singh
PSPawan Sharma
Pawan Sharma
GFGail Forrest
Gail Forrest
SHSusan Harkema
Susan Harkema
ABAndrea Behrman
Andrea Behrman
Yury P. GerasimenkoYury P. Gerasimenko
Yury P. Gerasimenko
Cervical spinal cord injury (SCI) results in significant sensorimotor impairments below the injury level, notably in the upper extremities (UEs), impacting daily activities and quality of life. Regaining UE function remains the top priority for individuals post-cervical SCI. Recent advances in understanding adaptive plasticity within the sensorimotor system have led to the development of novel non-invasive neurostimulation strategies, such as spinal cord transcutaneous stimulation (scTS), to facilitate UE motor recovery after SCI. This comprehensive review investigates the neuromotor control of UE, the typical recovery trajectories following SCI, and the therapeutic potential of scTS to enhance UE motor function in individuals with cervical SCI. Although limited in number with smaller sample sizes, the included research articles consistently suggest that scTS, when combined with task-specific training, improves voluntary control of arm and hand function and sensation. Further, the reported improvements translate to the recovery of various UE functional tasks and positively impact the quality of life in individuals with cervical SCI. Several methodological limitations, including stimulation site selection and parameters, training strategies, and sensitive outcome measures, require further advancements to allow successful translation of scTS from research to clinical settings. This review also summarizes the current literature and proposes future directions to support establishing approaches for scTS as a viable neuro-rehabilitative tool.