Kyi Zin Thant

Kyi Zin Thant

Auto-generated profile, based on publicly available information

Kyi Zin Thant

Department of Cardiology, Glenfield Hospital , Leicester

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 May 2026 in medRxiv
Verified
Preprint
Open access
PDF file
KTKyi Zin Thant
Kyi Zin Thant
IAIbrahim Antoun
Ibrahim Antoun
KTKaung Myat Thu
Kaung Myat Thu
RSRiyaz Somani
Riyaz Somani
ZVZakariyya Vali
Zakariyya Vali
MIMokhtar Ibrahim
Mokhtar Ibrahim
Background: Atrial high-rate episodes (AHRE) detected by cardiac implantable electronic devices (CIEDs) are associated with increased thromboembolic risk, yet their clinical significance and optimal anticoagulation strategy remain uncertain, particularly in the absence of electrocardiogram (ECG)-confirmed atrial fibrillation. Methods: We conducted a nationwide cross-sectional survey of UK clinicians involved in CIED follow-up. The survey assessed anticoagulation decision-making in AHRE, including episode-duration thresholds, cumulative burden, CHA 2 DS 2 -VA use, additional ECG monitoring, and anticoagulant choice. Only responses from UK-based consultant clinicians were included and analysed descriptively. Results: A total of 51 responses were received; 38 met the inclusion criteria and were analysed. Most respondents (86.8%) reported having reviewed AHRE alerts within the preceding six months, indicating that AHRE are commonly encountered in clinical practice. A ≥24-hour episode was the most common threshold for anticoagulation (44.7%), although many clinicians reported lower thresholds or individualised approaches. Nearly half (44.7%) did not consider cumulative AHRE burden in decision-making. CHA 2 DS 2 -VA thresholds also varied, most commonly ≥2 or ≥1. Additional ECG monitoring was infrequently performed. Direct oral anticoagulants were universally preferred, with apixaban the most commonly selected agent (73.7%). Conclusion: There is substantial variation in UK clinical practice regarding anticoagulation for AHRE, reflecting ongoing uncertainty and lack of clear guidance. These findings highlight the need for evidence-based thresholds to support consistent and informed clinical decision-making.

10 October 2026 in European Heart Journal - Case Reports
Verified
Journal Article
Open access
KTKyi Zin Thant
Kyi Zin Thant
IAIbrahim Antoun
Ibrahim Antoun
RSRiyaz Somani
Riyaz Somani
Background: Recurrence of atrial flutter after extensive left- and right-atrial ablation strategies poses a significant clinical challenge, particularly in patients with complex atrial substrates. The use of pulsed field ablation (PFA) with a balloon-in-basket system (Volt™, Abbott) represents a novel platform with promising myocardial tissue selectivity. However, clinical experience targeting extra-pulmonary vein substrate remains limited, with few reported cases to date. Case summary: We describe a 59-year-old woman with recurrent symptomatic atypical atrial flutter despite multiple prior radiofrequency ablation procedures, which included cavotricuspid isthmus (CTI) ablation, pulmonary vein isolation (PVI), a left atrial roofline, posterior mitral isthmus ablation, and additional ablation at the base of the left atrial appendage, for persistent atrial fibrillation and atrial flutter. The patient developed left ventricular systolic dysfunction, which was attributed to arrhythmia and improved after restoration of sinus rhythm. Due to intolerance of sotalol, propafenone and amiodarone, and symptomatic flutter recurrence, she was listed for redo ablation using PFA (Volt). After confirming the presence of an atypical atrial flutter within the left atrium, PFA using the balloon-in-basket catheter was employed to target the substrate for atypical flutter. Atrial flutter terminated with delivery of pulsed field ablation without acute complications. The patient remained in stable sinus rhythm without recurrence of atrial tachyarrhythmia during three-month follow-up. Discussion: This case highlights the feasibility and potential efficacy of PFA using the balloon-in-basket catheter in treating complex atrial flutter after multiple failed conventional ablations.

1 November 2026 in Journal of Cardiovascular Electrophysiology
Verified
Journal Article
Open access
PDF file
KTKyi Zin Thant
Kyi Zin Thant
IAIbrahim Antoun
Ibrahim Antoun
KTKaung Myat Thu
Kaung Myat Thu
RSRiyaz Somani
Riyaz Somani
ZVZakariyya Vali
Zakariyya Vali
MIMokhtar Ibrahim
Mokhtar Ibrahim
Background: Atrial high‐rate episodes (AHRE) detected by cardiac implantable electronic devices (CIEDs) are associated with increased thromboembolic risk, yet their clinical significance and optimal anticoagulation strategy remain uncertain, particularly in the absence of electrocardiogram (ECG)‐confirmed atrial fibrillation. Methods: We conducted a nationwide cross‐sectional survey of UK clinicians involved in CIED follow‐up. The survey assessed anticoagulation decision‐making in AHRE, including episode‐duration thresholds, cumulative burden, CHA 2 DS 2 ‐VA use, additional ECG monitoring, and anticoagulant choice. Only responses from UK‐based consultant clinicians were included and analysed descriptively. Results: A total of 51 responses were received; 38 met the inclusion criteria and were analysed. Most respondents (86.8%) reported having reviewed AHRE alerts within the preceding 6 months, indicating that AHRE are commonly encountered in clinical practice. A ≥ 24‐h episode was the most common threshold for anticoagulation (44.7%), although many clinicians reported lower thresholds or individualised approaches. Nearly half (44.7%) did not consider cumulative AHRE burden in decision‐making. CHA 2 DS 2 ‐VA thresholds also varied, most commonly ≥ 2 or ≥ 1. Additional ECG monitoring was infrequently performed. Direct oral anticoagulants were universally preferred, with apixaban the most commonly selected agent (73.7%). Conclusion: There is substantial variation in UK clinical practice regarding anticoagulation for AHRE, reflecting ongoing uncertainty and lack of clear guidance. These findings highlight the need for evidence‐based thresholds to support consistent and informed clinical decision‐making.