Ligong Wang

Ligong Wang

Auto-generated profile, based on publicly available information

Ligong Wang

School of Radiation Medicine and Protection, Suzhou Medical College of Soochow University, Suzhou, China

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2014 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
LWLigong Wang
Ligong Wang
Ravinder R RegatteRavinder R Regatte
Ravinder R Regatte
Magnetic resonance imaging (MRI) offers the direct visualization of the human musculoskeletal (MSK) system, especially all diarthrodial tissues including cartilage, bone, menisci, ligaments, tendon, hip, synovium, etc. Conventional MRI techniques based on T1‐ and T2‐weighted, proton density (PD) contrast are inconclusive in quantifying early biochemically degenerative changes in MSK system in general and articular cartilage in particular. In recent years, quantitative MR parameter mapping techniques have been used to quantify the biochemical changes in articular cartilage, with a special emphasis on evaluating joint injury, cartilage degeneration, and soft tissue repair. In this article we focus on cartilage biochemical composition, basic principles of T1ρ MRI, implementation of T1ρ pulse sequences, biochemical validation, and summarize the potential applications of the T1ρ MRI technique in MSK diseases including osteoarthritis (OA), anterior cruciate ligament (ACL) injury, and knee joint repair. Finally, we also review the potential advantages, challenges, and future prospects of T1ρ MRI for widespread clinical translation. J. Magn. Reson. Imaging 2015;41:586–600. © 2014 Wiley Periodicals, Inc.

1 September 2012 in European Journal of Radiology
Verified
Journal Article
Closed access
LWLigong Wang
Ligong Wang
GCGregory Chang
Gregory Chang
JXJian Xu
Jian Xu
RVRenata L.R. Vieira
Renata L.R. Vieira
SKSvetlana Krasnokutsky
Svetlana Krasnokutsky
Ravinder R RegatteRavinder R Regatte
Ravinder R Regatte

26 August 2009 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
LWLigong Wang
Ligong Wang
YWYan Wu
Yan Wu
GCGregory Chang
Gregory Chang
NONiels Oesingmann
Niels Oesingmann
MSMark E. Schweitzer
Mark E. Schweitzer
Ravinder R RegatteRavinder R Regatte
Ravinder R Regatte
Purpose: To demonstrate the feasibility of acquiring high‐resolution, isotropic 3D‐sodium magnetic resonance (MR) images of the whole knee joint in vivo at ultrahigh field strength (7.0T) via a 3D‐radial acquisition with ultrashort echo times and clinically acceptable acquisition times.Materials and Methods: Five healthy controls (four males, one female; mean ± standard deviation [SD] age 28.7 ± 4.8 years) and five patients with osteoarthritis (OA) (three males, two females; mean ± SD age 52.4 ± 5.6 years) underwent 23Na MRI on a 7T, multinuclei equipped whole‐body scanner. A quadrature 23Na knee coil and a 3D‐gradient echo (GRE) imaging sequence with a radial acquisition were utilized. Cartilage sodium concentration was measured and compared between the healthy controls and OA patients.Results: The average signal‐to‐noise ratio (SNR) for different spatial resolutions (1.2–4 mm) varied from ∼14–120, respectively. The mean sodium concentration of healthy subjects ranged from ∼240 ± 28 mM/L to 280 ± 22 mM/L. However, in OA patients the sodium concentrations were reduced significantly by ∼30%–60%, depending on the degree of cartilage degeneration.Conclusion: The preliminary results suggest that sodium imaging at 7T may be a feasible potential alternative for physiologic OA imaging and clinical diagnosis. J. Magn. Reson. Imaging 2009;30:606–614.

25 February 2010 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
GCGregory Chang
Gregory Chang
KFKlaus M. Friedrich
Klaus M. Friedrich
LWLigong Wang
Ligong Wang
RVRenata L.R. Vieira
Renata L.R. Vieira
MSMark E. Schweitzer
Mark E. Schweitzer
Ravinder R RegatteRavinder R Regatte
Ravinder R Regatte
Purpose: To determine the feasibility of performing MRI of the wrist at 7 Tesla (T) with parallel imaging and to evaluate how acceleration factors (AF) affect signal‐to‐noise ratio (SNR), contrast‐to‐noise ratio (CNR), and image quality.Materials and Methods: This study had institutional review board approval. A four‐transmit eight‐receive channel array coil was constructed in‐house. Nine healthy subjects were scanned on a 7T whole‐body MR scanner. Coronal and axial images of cartilage and trabecular bone micro‐architecture (3D‐Fast Low Angle Shot (FLASH) with and without fat suppression, repetition time/echo time = 20 ms/4.5 ms, flip angle = 10°, 0.169–0.195 × 0.169–0.195 mm, 0.5–1 mm slice thickness) were obtained with AF 1, 2, 3, 4. T1‐weighted fast spin‐echo (FSE), proton density‐weighted FSE, and multiple‐echo data image combination (MEDIC) sequences were also performed. SNR and CNR were measured. Three musculoskeletal radiologists rated image quality. Linear correlation analysis and paired t‐tests were performed.Results: At higher AF, SNR and CNR decreased linearly for cartilage, muscle, and trabecular bone (r < −0.98). At AF 4, reductions in SNR/CNR were:52%/60% (cartilage), 72%/63% (muscle), 45%/50% (trabecular bone). Radiologists scored images with AF 1 and 2 as near‐excellent, AF 3 as good‐to‐excellent (P = 0.075), and AF 4 as average‐to‐good (P = 0.11).Conclusion: It is feasible to perform high resolution 7T MRI of the wrist with parallel imaging. SNR and CNR decrease with higher AF, but image quality remains above‐average. J. Magn. Reson. Imaging 2010;31:740–746.

1 April 2014 in Academic Radiology
Verified
Journal Article
Closed access
LWLigong Wang
Ligong Wang
Ravinder R RegatteRavinder R Regatte
Ravinder R Regatte

23 March 2010 in European Radiology
Verified
Journal Article
Closed access
PDF file
GCGregory Chang
Gregory Chang
LWLigong Wang
Ligong Wang
MSMark E. Schweitzer
Mark E. Schweitzer
Ravinder R RegatteRavinder R Regatte
Ravinder R Regatte