10 December 2018 in IEEE Transactions on Nuclear Science
This paper focuses on the radiation-induced dose and single event effects on a color CMOS camera designed for space missions. Gamma-ray and protons are used to evaluate the tolerance against cumulative dose effects. The dark current of the image sensor is the main parameter impacted by dose effects. Heavy ions testing is performed to evaluate single event effects. SEU, SEFI and SEL have been observed and mitigation techniques were proposed for specific space missions.
1 February 2018 in IEEE Transactions on Nuclear Science
In-flight Dark Current Non Uniformity measurements performed on three different satellites (JASON-2, SPRINT-A and SAT-X (name withheld)) are compared to ground calculations. The standard deviation of the DCNU is calculated using both the AP8 and AP9 environment models. These predictions are compared to some calculations made with proton fluxes measured with the ICARE-NG spectrometer embedded on the JASON-2 satellite. The reliability of AP8 and AP9 models is analyzed. AP9 model appears to consistently overestimate the in-flight degradation.
29 April 2024 in IEEE Transactions on Nuclear Science
A methodology for radiation lot acceptance at board level is proposed. A worst-case analysis of a DC/DC converter board has been performed per two analytical methods and per a Monte Carlo simulation. Six samples of the board have been tested to confront the analysis results with temperature effects (-55, +25, and +125°C), ageing effects (1300 h at 120°C), and ionizing dose effects (20, 50, and 105 krad(Si)). The tested board functions are found to be almost only dependent on the temperature whereas significant degradation by ageing and dose could be expected from the analysis.
17 March 2026 in IEEE Transactions on Nuclear Science
Radiation-induced degradation arising from the operation principle of Global Shutter (GS) CMOS Image Sensors (CIS) are studied. The study is focused on voltage domain and charge domain pixels irradiated with γ-rays up to 50.2 krad and 62-MeV protons with Displacement Damage Doses (DDD) reaching 1492 TeV/g. Increased charge generation rate in voltage and charge domain pixels memory nodes (MN), and thus increased Parasitic Storage Node Leakage (PSNL), are highlighted. For the charge domain XGS16M detector, the PSNL degradation is explained by the increasing number of charges in the storage node before the row readout, due to radiation-induced interface traps and defect clusters within the silicon volume. HDPYX330-G charge domain pixels, embedding Capacitive Deep Trench Isolation (CDTI) technology and vertical storage of charges during the sensor readout, are less sensitive to Total Ionizing Dose (TID) effects but more vulnerable to DDD due to a deeper silicon volume in the MN area. For the CMV2000 voltage domain detector, asymmetries in the MN architecture using two collecting capacitors lead to a mean PSNL increase and PSNL non-uniformity (PSNLNU), meaning the increase of the row standard deviation with the readout. On the other hand, Parasitic Light Sensitivity (PLS) is not affected by γ-ray or proton irradiation for all detector types. The contribution of TID and DDD defects on the pixel MN are distinguished by studying the induced PSNL distributions. Voltage domain-based pixels seem to exhibit better performances with respect to ionizing radiation compared to charge domain detectors. Furthermore, PSNL distributions indicate that both TID and DDD contribute to the PSNL degradation of the two charge domain detectors, but also highlight the lower TID sensitivity of the HDPYX330-G sensor. Finally, activation energy measurements point out the diversity of defects contributing to the PSNL depending on the charge domain detector under study, and thus depending on the MN design. Independently on the type of signal storage before row-by-row readout, PSNL characterizations appear to be mandatory when studying GS CIS under irradiation.