Tomohiro Nishinaka

Tomohiro Nishinaka

Auto-generated profile, based on publicly available information

Tomohiro Nishinaka

Tokyo Women’s Medical University

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 January 2021 in The International Journal of Artificial Organs
Verified
Journal Article
Closed access
PDF file
TTTakuma Takada
Takuma Takada
TNTomohiro Nishinaka
Tomohiro Nishinaka
YIYuki Ichihara
Yuki Ichihara
SSSatoshi Saito
Satoshi Saito
YIYasutaka Imamura
Yasutaka Imamura
HNHiroshi Niinami
Hiroshi Niinami
Objectives: Stroke is a substantial complication of left ventricular assist device (LVAD) implantation. The relationship between stroke and the anatomical position of the inflow cannula of patients who underwent LVAD implantation was investigated. Methods: We enrolled 15 patients with advanced-stage heart failure who underwent implantation of continuous-flow-LVAD. Data of patients who suffered a stroke within 6 months after LVAD implantation were retrospectively compared to those who remained free of stroke. The distance between the inflow duct and left ventricular (LV) septum (duct-sep distance) and its ratio to LV diastolic diameter (LVDd) were measured from echocardiography at 1 month after LVAD implantation. Receiver operating characteristic curves for the endpoint of stroke using the duct-sep distance to LVDd ratio was created and the cut-off value was calculated. The incidence of stroke during the 6 months after LVAD implantation according to this ratio was estimated using the Kaplan-Meier method. Results: At 1 month after LVAD implantation, there were no significant differences in baseline characteristics and echocardiography parameters between the stroke and stroke-free groups. Receiver operating characteristic curve analysis for the endpoint of stroke using the duct-sep distance to LVDd ratio revealed 0.217 as a cut-off value (sensitivity: 80%, specificity: 80%, area under the curve: 0.72). Stroke was more frequent in patients with a duct-sep distance to LVDd ratio ⩾0.217 at 1 month than in those with a lower ratio. Conclusion: The duct-sep distance to LVDd ratio was associated with the occurrence of stroke, suggesting that inflow cannula position influences the incidence of stroke.

23 August 2022 in Artificial Organs
Verified
Journal Article
Closed access
STShun Tanaka
Shun Tanaka
TNTomohiro Nishinaka
Tomohiro Nishinaka
AUAkihide Umeki
Akihide Umeki
MFMasahiko Fujii
Masahiko Fujii
SIShusuke Imaoka
Shusuke Imaoka
MOMinoru Ono
Minoru Ono

26 February 2014 in Journal of Artificial Organs
Verified
Journal Article
Closed access
PDF file
ASAnd Yoshiki Sawa
And Yoshiki Sawa
JCJournal of Artificial Organs Editorial Committee
Journal of Artificial Organs Editorial Committee
ETE. Tatsumi
E. Tatsumi
TTT. Tsukiya
T. Tsukiya
KMK. Matsuda
K. Matsuda
TYTetsuji Yamaoka
Tetsuji Yamaoka

1 January 2022 in Journal of the Japan Society of Applied Electromagnetics and Mechanics
Verified
Journal Article
Open access
PDF file
TYToshihiro Yamashita
Toshihiro Yamashita
TMToru Masuzawa
Toru Masuzawa
MOMasahiro Osa
Masahiro Osa
ETEisuke Tatsumi
Eisuke Tatsumi
TNTomohiro Nishinaka
Tomohiro Nishinaka
An ultra-compact ventricular assist device with an axial gap type self-bearing motor has been developed for use in pediatric circulatory support. The developed self-bearing motor has double stator structure to actively control five degrees of freedom (DOF) of levitated impeller postures and to enhance motor torque capacity with small device size which is 22 mm in outer diameter and 33.6 mm in total height, respectively. This study investigated magnetic suspension stability and energy consumption characteristics during pump operation with 3-DOF (z, θx, θy) control and 5-DOF (x, y, z, θx, θy) control. The axial position and inclination angles were sufficiently stabilized independently with the radial position control. The radial position control can be effective to suppress the radial whirling oscillation at resonance, however power consumption increased by up to 0.4-0.9 W compared to in the case of the motor utilizing 3-DOF control.

20 February 2016 in Journal of Artificial Organs
Verified
Journal Article
Closed access
PDF file
ASAnd Yoshiki Sawa
And Yoshiki Sawa
KMK Matsuda
K Matsuda
ETE Tatsumi
E Tatsumi
GMG Matsumiya
G Matsumiya
TTT Tsukiya
T Tsukiya
TYTetsuji Yamaoka
Tetsuji Yamaoka

1 October 2014 in Journal of Cardiac Failure
Verified
Journal Article
Open access
PDF file
KTKei Tsukamoto
Kei Tsukamoto
ASAtsushi Suzuki
Atsushi Suzuki
HHHidetoshi Hattori
Hidetoshi Hattori
TSTsuyoshi Shiga
Tsuyoshi Shiga
HTHiroyuki Tukui
Hiroyuki Tukui
NHNobuhisa Hagiwara
Nobuhisa Hagiwara
Heart transplantation provides an effective treatment for selected patients with end-stage heart failure (HF). In Japan, candidate patients are waiting long time. Patients with inotropy-dependent low-output HF have a very high mortality risk. The aim of this study was to review the outcome of Japanese patients who evaluated for heart transplantation and who have severe HF dependent on inotropic support.