Tobias Gauer

Tobias Gauer

Auto-generated profile, based on publicly available information

Tobias Gauer

Department of Radiotherapy and Radio-Oncology, University Medical Center Hamburg-Eppendorf, Martinistrasse 52, Hamburg 20246, Germany

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2017 in Dentomaxillofacial Radiology
Verified
Journal Article
Closed access
Ralf SmeetsRalf Smeets
Ralf Smeets
MSMaximilian Schöllchen
Maximilian Schöllchen
TGTobias Gauer
Tobias Gauer
GAGhazal Aarabi
Ghazal Aarabi
AAAlexandre Thomas Assaf
Alexandre Thomas Assaf
SSSusanne Siemonsen
Susanne Siemonsen
Objectives:To analyze and evaluate imaging artefacts induced by zirconium, titanium and titanium–zirconium alloy dental implants.Methods:Zirconium, titanium and titanium–zirconium alloy implants were embedded in gelatin and MRI, CT and CBCT were performed. Standard protocols were used for each modality. For MRI, line–distance profiles were plotted to quantify the accuracy of size determination. For CT and CBCT, six shells surrounding the implant were defined every 0.5 cm from the implant surface and histogram parameters were determined for each shell.Results:While titanium and titanium–zirconium alloy induced extensive signal voids in MRI owing to strong susceptibility, zirconium implants were clearly definable with only minor distortion artefacts. For titanium and titanium–zirconium alloy, the MR signal was attenuated up to 14.1 mm from the implant. In CT, titanium and titanium–zirconium alloy resulted in less streak artefacts in comparison with zirconium. In CBCT, titanium–zirconium alloy induced more s...

19 June 2017 in Radiation Oncology
Verified
Journal Article
Open access
PDF file
RWRene Werner
Rene Werner
CHChristian Hofmann
Christian Hofmann
EMEike Mücke
Eike Mücke
TGTobias Gauer
Tobias Gauer
Respiration-correlated CT (4D CT) is the basis of radiotherapy treatment planning of thoracic and abdominal tumors. Current clinical 4D CT images suffer, however, from artifacts due to unfulfilled assumptions concerning breathing pattern regularity. We propose and evaluate modifications to existing low-pitch spiral 4D CT reconstruction protocols to counteract respective artifacts. The proposed advanced reconstruction (AR) approach consists of two steps that build on each other: (1) statistical analysis of the breathing signal recorded during CT data acquisition and extraction of a patient-specific reference breathing cycle for projection binning; (2) incorporation of an artifact measure into the reconstruction. 4D CT data of 30 patients were reconstructed by standard phase- and local amplitude-based reconstruction (PB, LAB) and compared with images obtained by AR. The number of artifacts was evaluated and artifact statistics correlated to breathing curve characteristics. AR reduced the number of 4D CT artifacts by 31% and 27% compared to PB and LAB; the reduction was most pronounced for irregular breathing curves. We described a two-step optimization of low-pitch spiral 4D CT reconstruction to reduce artifacts in the presence of breathing irregularity and illustrated that the modifications to existing reconstruction solutions are effective in terms of artifact reduction.

15 February 2018 in Strahlentherapie und Onkologie
Verified
Journal Article
Closed access
PDF file
TGTobias Gauer
Tobias Gauer
TSThilo Sothmann
Thilo Sothmann
OBOliver Blanck
Oliver Blanck
CPCordula Petersen
Cordula Petersen
RWRene Werner
Rene Werner

31 March 2023 in Strahlentherapie und Onkologie
Verified
Journal Article
Open access
PDF file
RWRene Werner
Rene Werner
JSJuliane Szkitsak
Juliane Szkitsak
FMFrederic Madesta
Frederic Madesta
LBLaura Büttgen
Laura Büttgen
LWLukas Wimmert
Lukas Wimmert
CHChristian Hofmann
Christian Hofmann
Purpose: 4D CT imaging is an integral part of 4D radiotherapy workflows. However, 4D CT data often contain motion artifacts that mitigate treatment planning. Recently, breathing-adapted 4D CT (i4DCT) was introduced into clinical practice, promising artifact reduction in in-silico and phantom studies. Here, we present an image quality comparison study, pooling clinical patient data from two centers: a new i4DCT and a conventional spiral 4D CT patient cohort.Methods: The i4DCT cohort comprises 129 and the conventional spiral 4D CT cohort 417 4D CT data sets of lung and liver tumor patients. All data were acquired for treatment planning. The study consists of three parts: illustration of image quality in selected patients of the two cohorts with similar breathing patterns; an image quality expert rater study; and automated analysis of the artifact frequency.Results: Image data of the patients with similar breathing patterns underline artifact reduction by i4DCT compared to conventional spiral 4D CT. Based on a subgroup of 50 patients with irregular breathing patterns, the rater study reveals a fraction of almost artifact-free scans of 89% for i4DCT and only 25% for conventional 4D CT; the quantitative analysis indicated a reduction of artifact frequency by 31% for i4DCT.Conclusion: The results demonstrate 4D CT image quality improvement for patients with irregular breathing patterns by breathing-adapted 4D CT in this first corresponding clinical data image quality comparison study.

23 May 2023 in Cancers
Verified
Journal Article
Open access
PDF file
AHAlexander Heitkamp
Alexander Heitkamp
FMFrederic Madesta
Frederic Madesta
SASophia Amberg
Sophia Amberg
SWSchohla Wahaj
Schohla Wahaj
TSTanja Schröder
Tanja Schröder
HKHelge C. Kniep
Helge C. Kniep
Discordance and conversion of receptor expressions in metastatic lesions and primary tumors is often observed in patients with brain metastases from breast cancer. Therefore, personalized therapy requires continuous monitoring of receptor expressions and dynamic adaptation of applied targeted treatment options. Radiological in vivo techniques may allow receptor status tracking at high frequencies at low risk and cost. The present study aims to investigate the potential of receptor status prediction through machine-learning-based analysis of radiomic MR image features. The analysis is based on 412 brain metastases samples from 106 patients acquired between 09/2007 and 09/2021. Inclusion criteria were as follows: diagnosed cerebral metastases from breast cancer; histopathology reports on progesterone (PR), estrogen (ER), and human epidermal growth factor 2 (HER2) receptor status; and availability of MR imaging data. In total, 3367 quantitative features of T1 contrast-enhanced, T1 non-enhanced, and FLAIR images and corresponding patient age were evaluated utilizing random forest algorithms. Feature importance was assessed using Gini impurity measures. Predictive performance was tested using 10 permuted 5-fold cross-validation sets employing the 30 most important features of each training set. Receiver operating characteristic areas under the curves of the validation sets were 0.82 (95% confidence interval [0.78; 0.85]) for ER+, 0.73 [0.69; 0.77] for PR+, and 0.74 [0.70; 0.78] for HER2+. Observations indicate that MR image features employed in a machine learning classifier could provide high discriminatory accuracy in predicting the receptor status of brain metastases from breast cancer.

1 September 2015 in Current Directions in Biomedical Engineering
Verified
Journal Article
Open access
PDF file
JOJ. Ortmüller
J. Ortmüller
TGT. Gauer
T. Gauer
MWMatthias Wilms
Matthias Wilms
HHH. Handels
H. Handels
RWRene Werner
Rene Werner
In radiotherapy of abdominal and thoracic tumors, respiratory motion is a problem for an accurate treatment. Most current motion compensation techniques rely on externally acquired breathing signals of the patient. The systems in clinical use usually work with 1D surface motion signals to describe internal structure respiratory motion patterns. As a 1D signal is not able to describe complex motion patterns and breathing variations, in this work the Microsoft Kinect, which can record multidimensional respiratory surface motion signals, is proposed to be used instead. For the Kinect, a clinically acceptable measurement setup is designed and Kinect measurements are compared to the Varian RPM system (clinical standard). The results show that the signals are well aligned. An additional comparison of Kinect signals from different regions of interest on the chest further reveals variations between them. This illustrates that the use of a system that provides multidimensional signals is worthwhile; the knowledge about breathing variations could be applied for optimization of current clinical workflows