Electrical power systems are exposed to transient disturbances that change the voltage and current signals of the network, which can interrupt power and damage equipment. In high-frequency phenomena, it is essential to study the transient recovery voltage (TRV) to ensure the electrical insulation limits of circuit breakers are not violated, thus leading to a safe and reliable operation. Adequate models are crucial to achieving satisfactory results in the studies, according to the range of frequency of the transient being evaluated. This paper presents a comprehensive literature review of methods and models for studying electromagnetic transients, focusing on TRV requests imposed on circuit breakers, in addition to fault-clearing simulations on real system modeling. The analyses are fundamental both for the evaluation of the amplitude of the voltage signal and for its rate of rise. We also compare the reviewed models and techniques to provide a handy resource for researchers.
11 October 2021 in IEEE Transactions on Industry Applications
The soil characterization is one of the major prerequisites in grounding system studies. Along with an adequate measurement procedure and a reliable field data processing, they are responsible for the success in the design and the installation of grounding grids in electrical power systems. In this frame of reference, the purpose of this work is to present an embracing investigation combining in-situ measuring data from soil resistivity and geological survey, supported by the Wenner Method and Standard Penetration Test (SPT). The study is focused on investigating the differences in the apparent soil resistivity interpretation, provided by distinct approaches, identifying the one that better correlates with SPT. Furthermore, a geo-electrical and geo-technical soil characterization is in-depth evaluated, culminating in the derivations among soil resistivity, moisture content and its mechanical properties. The study has a particular application, but not restricted, to electrical substations design, in which a proper soil modeling and representation are mandatory. The obtained results are promising serving as foundation for further investigation.
Two important short-term voltage variation monitoring standards have recently been updated: IEEE 1564 and Distribution Procedures Module 8 (PRODIST) of the Brazilian National Regulatory Agency (ANEEL). The present work deals with a comparative analysis of both regulatory procedures, within the scope of the indices and reference standards implemented for the case of voltage sags. In order to achieve such a comparison, case studies of voltage sags are studied. Thus, in addition to showing the main updates and differences between the standardizations, the limitations on the classification of events by each case study case are also highlighted.
2 November 2023 in IEEE Industry Applications Magazine
The arguments regarding the usage of dc instead of its counterpart in ac have been discussed for a long time. Aiming for an efficient connection interface for the insertion of renewable energy sources (RESs) on the grid and the reduction of distribution losses, the employment of a low-voltage dc (LVdc) distribution system is considered in this study. For this purpose, the modification of an original low-voltage ac (LVac) distribution system to a dc one, without network rerouting and with minimal adaptations, is proposed. Both systems were implemented in the electric power open source distribution system simulator OpenDSS (open source code) and compared regarding their losses, energy transferred to the loads, voltage drops along the line as well as the number of conductors required for their operation. Moreover, different dc/ac conversion efficiency levels required by the penetration of solar photovoltaic (PV) systems as a RES on the grid were investigated, highlighting the discussion regarding the performance of operation modes.
29 April 2024 in IEEE Transactions on Industry Applications
In the commissioning of high-voltage substations, the determination of the grounding grid resistance stands out. In real-life procedures, usually the involved measurements are carried out considering the guard wires of the transmission lines connected to the substation grounding grid. This issue can lead to an overestimation of the ground current, which may indicate an erroneous unsafe grid condition, in terms of touch and step voltages exposed to human beings. Considering the practical difficulty or impossibility of measuring the portion of the total fault current flowing through the ground, this paper deals with the proposition of a formulation (equation that govern the phenomenon) to estimate the ground current. The proposed simplified approach is based on an optimization method subject to adequate constraints, in which the determination of the substation grid resistance and the equivalent impedance of the guard wires allow estimating the most important parameter: the portion of the total ground-fault current that produces the touch and step voltages. The methodology was compared with results available in the literature and with field tests performed in a real substation.
This paper investigates the converting feasibility of low voltage alternating current (LVAC) networks into low voltage direct current (LVDC) counterpart. Addressing the insertion of distributed energy resources (DER) in the grid, in terms of electrical losses and power capacity, the work proposes a methodology supported by computational simulation aiming at the increase of the system efficiency. The study is conducted on a low voltage European residential network model, where the conventional LVAC and an equivalent LVDC topologies are confronted. Based on several scenarios, with and without the presence of DER in different penetration levels and also considering unbalanced loads, the DC configuration demonstrates to be an adequate interface for the insertion of DER, reducing losses and facilitating the integration of new resources. Corroborating with the well-known benefits assigned to the high voltage direct current systems (HVDC), the relevance of the investigation can be highlighted by the advantages observed also in low voltage level.