Meriem Chrifi Alaoui

Meriem Chrifi Alaoui

Auto-generated profile, based on publicly available information

Meriem Chrifi Alaoui

IES UMR 5214, University of Montpellier, Montpellier, France

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 May 2025 in Ceramics International
Verified
Journal Article
Closed access
MZMeriem Ben Zennou
Meriem Ben Zennou
ABAhmed Bachar
Ahmed Bachar
MAMeriem Chrifi Alaoui
Meriem Chrifi Alaoui
FJFrédéric Jenot
Frédéric Jenot
RARachid Amrousse
Rachid Amrousse
AMAssia Mabrouk
Assia Mabrouk

10 October 2018 in IEEE Transactions on Nuclear Science
Verified
Journal Article
Closed access
GZGhita Zaz
Ghita Zaz
ECEmmanuel Le Clézio
Emmanuel Le Clézio
ADAli Dekious
Ali Dekious
MAMeriem Chrifi Alaoui
Meriem Chrifi Alaoui
YCYoann Calzavara
Yoann Calzavara
GDGilles Despaux
Gilles Despaux
Most of the high-performance research reactors are made of plates undergoing limited structural modifications during irradiation. Measuring the fuel thickness or the interplate distance is then a promising way to obtain information on the fuel element irradiation history. The experimental constraints are, however, quite heavy due to the aimed resolution and the element geometry. In order to perform such measurements, a high-resolution ultrasonic device was designed. It was thinned down to a 1 mm thickness in order to be inserted into the reactor water channel. The system was then excited with a 120-MHz central frequency burst and distance measurements were carried out through ultrasonic waves' time-of-flight estimations. A series of experiments was performed on a full-size irradiated fuel element of the “Institut Laue-Langevin” reactor proving the feasibility of real-time in situ measurements.

17 July 2024 in NDT & E International
Verified
Journal Article
Closed access
MBMustapha Baher
Mustapha Baher
MAMeriem Chrifi Alaoui
Meriem Chrifi Alaoui
FJFrédéric Jenot
Frédéric Jenot
MOMohammadi Ouaftouh
Mohammadi Ouaftouh
MDMarc Duquennoy
Marc Duquennoy

1 September 2026 in e-Journal of Nondestructive Testing
Verified
Journal Article
Open access
PDF file
UFUniversité Polytechnique Des Hauts de France
Université Polytechnique Des Hauts de France
MAMeriem Chrifi Alaoui
Meriem Chrifi Alaoui
MBMustapha Baher
Mustapha Baher
FJFrédéric Jenot
Frédéric Jenot
MOMohammadi Ouaftouh
Mohammadi Ouaftouh
FRFrédéric Rivart
Frédéric Rivart
Film adhesion is a critical phenomenon that has been thoroughly investigated to improve structural reliability, notably in microelectronics. In this work, Laser Ultrasonics is used to evaluate the bond quality achieved by an original electroadhesion process. More precisely, an electrostatic field is applied to a polyvinyl chloride film deposited on an aluminum substrate, thereby eliminating the need for an adhesive layer. The effects of electroadhesion on Surface Acoustic Waves (SAWs) are explored, with results solely attributable to interfacial adhesion changes. These waves are generated in thermoelastic regime by a frequency-doubled Nd:YAG pulsed laser and detected by a Mach-Zehnder heterodyne interferometer. The experimental Rayleigh mode dispersion curves are compared to the theoretical ones, facilitating adhesion evaluation through inverse problems. Furthermore, Finite Element Modeling predicts acoustic wave propagation in the structure, enabling experimental and numerical comparisons. This research paves the way for a multiphysical analysis of electrostatic field-induced coating adhesion.

3 April 2026
Verified
Thesis
Closed access
MAMeriem Chrifi Alaoui
Meriem Chrifi Alaoui
Développement d'un dispositif ultrasonore hautes fréquences pour la caractérisation post-irradiation de l'élément combustible du RHF: Les prochaines plaques combustibles faiblement enrichies des réacteurs HPRR devront résister à de hautes radiations et dévoileront probablement un gonflement. Ce dernier modifie la structure et influence la distance inter-plaque nominale. La mesure de cette distance à l'ordre micrométrique constitue l'objectif du projet PERSEUS via le développement d'un dispositif ultrasonore non-destructif. Réduit à 1 mm pour s'insérer dans l'interstice inter-plaque de 1.8 mm du Réacteur à Haut Flux (RHF), le dispositif comprend deux transducteurs ultrasonores reliés à un système électronique. Il permet les mesures de temps de vol et de vitesse ultrasonore. La faisabilité de mesure précédemment prouvée, des optimisations de la chaîne de mesure et du traitement du signal ont été intégrées, induisant une nouvelle génération de dispositif. Un banc motorisé a été développé et a permis des mesures de reproductibilité précises à 500 nm. La reproductibilité de résistance aux radiations, expérimentée à l'Institut Arc-Nucléart, a démontré la stabilité des dispositifs sous 3500 kGray. De plus, une expérience de mesure de distance inter-plaque sur l'élément combustible du RHF a permis les mesures de position verticale, de distance inter-plaque et de température avec 1 µm de précision d'épaisseur du canal d'eau. Une étude de faisabilité de focalisation des ondes est prévue pour analyser les plaques en profondeur.