Zijing Dong

Zijing Dong

Auto-generated profile, based on publicly available information

Zijing Dong

Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
XCXiaozhi Cao
Xiaozhi Cao
CLCongyu Liao
Congyu Liao
SISiddharth Srinivasan Iyer
Siddharth Srinivasan Iyer
ZWZhixing Wang
Zhixing Wang
ZZZihan Zhou
Zihan Zhou
KSKawin Setsompop
Kawin Setsompop

25 April 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
ZDZijing Dong
Zijing Dong
FWFuyixue Wang
Fuyixue Wang
TRTimothy G. Reese
Timothy G. Reese
BBBerkin Bilgic
Berkin Bilgic
KSKawin Setsompop
Kawin Setsompop

1 May 2021 in NeuroImage
Verified
Journal Article
Open access
ZDZijing Dong
Zijing Dong
FWFuyixue Wang
Fuyixue Wang
KCKwok-Shing Chan
Kwok-Shing Chan
TRTimothy G. Reese
Timothy G. Reese
BBBerkin Bilgic
Berkin Bilgic
KSKawin Setsompop
Kawin Setsompop
Myelin water imaging techniques based on multi-compartment relaxometry have been developed as an important tool to measure myelin concentration in vivo, but are limited by the long scan time of multi-contrast multi-echo acquisition. In this work, a fast imaging technique, termed variable flip angle Echo Planar Time-Resolved Imaging (vFA-EPTI), is developed to acquire multi-echo and multi-flip-angle gradient-echo data with significantly reduced acquisition time, providing rich information for multi-compartment analysis of gradient-echo myelin water imaging (GRE-MWI). The proposed vFA-EPTI method achieved 26 folds acceleration with good accuracy by utilizing an efficient continuous readout, optimized spatiotemporal encoding across echoes and flip angles, as well as a joint subspace reconstruction. An approach to estimate off-resonance field changes between different flip-angle acquisitions was also developed to ensure high-quality joint reconstruction across flip angles. The accuracy of myelin water fraction (MWF) estimate under high acceleration was first validated by a retrospective undersampling experiment using a lengthy fully-sampled data as reference. Prospective experiments were then performed where whole-brain MWF and multi-compartment quantitative maps were obtained in 5 min at 1.5 mm isotropic resolution and 24 min at 1 mm isotropic resolution at 3T. Additionally, ultra-high resolution data at 600 µm isotropic resolution were acquired at 7T, which show detailed structures within the cortex such as the line of Gennari, demonstrating the ability of the proposed method for submillimeter GRE-MWI that can be used to study cortical myeloarchitecture in vivo.

28 February 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
ZDZijing Dong
Zijing Dong
FWFuyixue Wang
Fuyixue Wang
LWLawrence Wald
Lawrence Wald
KSKawin Setsompop
Kawin Setsompop

18 November 2024 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
ZDZijing Dong
Zijing Dong
TRTimothy G. Reese
Timothy G. Reese
HLHong‐Hsi Lee
Hong‐Hsi Lee
SHSusie Y. Huang
Susie Y. Huang
JPJonathan R. Polimeni
Jonathan R. Polimeni
FWFuyixue Wang
Fuyixue Wang
Purpose: To overcome the major challenges in diffusion MRI (dMRI) acquisition, including limited SNR, distortion/blurring, and susceptibility to motion artifacts. Theory and Methods: A novel Romer‐EPTI technique is developed to achieve SNR‐efficient acquisition while providing distortion‐free imaging, minimal spatial blurring, high motion robustness, and simultaneous multi‐TE imaging. It introduces a ROtating‐view Motion‐robust supEr‐Resolution technique (Romer) combined with a distortion/blurring‐free Echo Planar Time‐resolved Imaging (EPTI) readout. Romer enhances SNR through simultaneous multi‐thick‐slice acquisition with rotating‐view encoding, while providing high motion‐robustness via a high‐fidelity, motion‐aware super‐resolution reconstruction. Instead of EPI, the in‐plane encoding is performed using EPTI readout to prevent geometric distortion, T 2 / T 2 *‐blurring, and importantly, dynamic distortions that could introduce additional blurring/artifacts after super‐resolution reconstruction due to combining volumes with inconsistent geometries. This further improves effective spatial resolution and motion robustness. Additional developments include strategies to address slab‐boundary artifacts, achieve minimized TE and optimized readout for additional SNR gain, and increase robustness to strong phase variations at high b ‐values. Results: Using Romer‐EPTI, we demonstrated distortion‐free whole‐brain mesoscale in‐vivo dMRI at both 3T (500‐μm isotropic [iso] resolution) and 7T (485‐μm iso resolution) for the first time. Motion experiments demonstrated the technique's motion robustness and its ability to obtain high‐resolution diffusion images in the presence of subject motion. Romer‐EPTI also demonstrated high SNR gain and robustness in high b ‐value ( b = 5000 s/mm 2 ) and time‐dependent dMRI. Conclusion: The high SNR efficiency, improved image quality, and motion robustness of Romer‐EPTI make it a highly efficient acquisition for high‐resolution dMRI and microstructure imaging.

28 April 2022 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
ZDZijing Dong
Zijing Dong
FWFuyixue Wang
Fuyixue Wang
KSKawin Setsompop
Kawin Setsompop