Yee Liang Thian

Yee Liang Thian

Auto-generated profile, based on publicly available information

Yee Liang Thian

Department of Diagnostic Imaging, National University Hospital, Singapore

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2021 in Radiology
Verified
Journal Article
Closed access
JHJames TPD Hallinan
James TPD Hallinan
LZLei Zhu
Lei Zhu
KYKaiyuan Yang
Kaiyuan Yang
AMAndrew Makmur
Andrew Makmur
DADiyaa Abdul Rauf Algazwi
Diyaa Abdul Rauf Algazwi
SQSwee Tian Quek
Swee Tian Quek
A deep learning model detected and classified lumbar spinal stenosis at MRI comparable with radiologists for central canal and lateral recess stenosis, with slightly lower agreement for neural fora... Background Assessment of lumbar spinal stenosis at MRI is repetitive and time consuming. Deep learning (DL) could improve ­productivity and the consistency of reporting. Purpose To develop a DL mod...

1 January 2019 in Radiology: Artificial Intelligence
Verified
Journal Article
Closed access
YTYee Liang Thian
Yee Liang Thian
YLYiting Li
Yiting Li
PJPooja Jagmohan
Pooja Jagmohan
DSDavid Sia
David Sia
VCVincent Ern Yao Chan
Vincent Ern Yao Chan
RTRobby T. Tan
Robby T. Tan
To demonstrate the feasibility and performance of an object detection convolutional neural network (CNN) for fracture detection and localization on wrist radiographs. Institutional review board approval was obtained with waiver of consent for this retrospective study. A total of 7356 wrist radiographic studies were extracted from a hospital picture archiving and communication system. Radiologists annotated all radius and ulna fractures with bounding boxes. The dataset was split into training (90%) and validation (10%) sets and used to train fracture localization models for frontal and lateral images. Inception-ResNet Faster R-CNN architecture was implemented as a deep learning model. The models were tested on an unseen test set of 524 consecutive emergency department wrist radiographic studies with two radiologists in consensus as the reference standard. Per-fracture, per-image (ie, per-view), and per-study sensitivity and specificity were determined. Area under the receiver operating characteristic curve (AUC) analysis was performed. The model detected and correctly localized 310 (91.2%) of 340 and 236 (96.3%) of 245 of all radius and ulna fractures on the frontal and lateral views, respectively. The per-image sensitivity, specificity, and AUC were 95.7% (95% confidence interval [CI]: 92.4%, 97.8%), 82.5% (95% CI: 77.4%, 86.8%), and 0.918 (95% CI: 0.894, 0.941), respectively, for the frontal view and 96.7% (95% CI: 93.6%, 98.6%), 86.4% (95% CI: 81.9%, 90.2%), and 0.933 (95% CI: 0.912, 0.954), respectively, for the lateral view. The per-study sensitivity, specificity, and AUC were 98.1% (95% CI: 95.6%, 99.4%), 72.9% (95% CI: 67.1%, 78.2%), and 0.895 (95% CI: 0.870, 0.920), respectively. The ability of an object detection CNN to detect and localize radius and ulna fractures on wrist radiographs with high sensitivity and specificity was demonstrated. © RSNA, 2019

1 October 2022 in Radiology
Verified
Journal Article
Closed access
DLDesmond Shi Wei Lim
Desmond Shi Wei Lim
AMAndrew Makmur
Andrew Makmur
LZLei Zhu
Lei Zhu
WZWenqiao Zhang
Wenqiao Zhang
ACAmanda J L Cheng
Amanda J L Cheng
JHJames TPD Hallinan
James TPD Hallinan
Radiologists assisted by deep learning for interpretation of lumbar spinal stenosis on MRI scans showed a marked reduction in reporting time and superior or equivalent interobserver agreement for a... Background Lumbar spine MRI studies are widely used for back pain assessment. Interpretation involves grading lumbar spinal stenosis, which is repetitive and time consuming. Deep learning (DL) coul...

1 January 2013 in Cancer Imaging
Verified
Journal Article
Open access
YTYee Liang Thian
Yee Liang Thian
ARAngela M. Riddell
Angela M. Riddell
DKDow-Mu Koh
Dow-Mu Koh
Liver-specific magnetic resonance (MR) contrast agents are increasingly used in evaluation of the liver. They are effective in detection and morphological characterization of lesions, and can be useful for evaluation of biliary tree anatomy and liver function. The typical appearances and imaging pitfalls of various tumours at MR imaging performed with these agents can be understood by the interplay of pharmacokinetics of these contrast agents and transporter expression of the tumour. This review focuses on the applications of these agents in oncological imaging.

1 July 2021 in Radiology: Artificial Intelligence
Verified
Journal Article
Closed access
YTYee Liang Thian
Yee Liang Thian
DNDianwen Ng
Dianwen Ng
JHJames Thomas Patrick Decourcy Hallinan
James Thomas Patrick Decourcy Hallinan
PJPooja Jagmohan
Pooja Jagmohan
SSSoon Yiew Sia
Soon Yiew Sia
MFMengling Feng
Mengling Feng
A deep learning model trained for pneumothorax detection with a large dataset of chest radiographs generalized well to multiple external datasets that were independent of the training data source. Purpose To assess the generalizability of a deep learning pneumothorax detection model on datasets from multiple external institutions and examine patient and acquisition factors that might influen...

1 April 2014 in Academic Radiology
Verified
Journal Article
Closed access
YTYee Liang Thian
Yee Liang Thian
WXWanying Xie
Wanying Xie
DPDavid A. Porter
David A. Porter
BABertrand Weileng Ang
Bertrand Weileng Ang