Yakov D. Zolotonosov

Yakov D. Zolotonosov

Auto-generated profile, based on publicly available information

Yakov D. Zolotonosov

Kazan State University of Architecture and Engineering

Research Focus & Metrics

Academic Career Length

39Years (1988-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in Fluid Dynamics
Verified
Journal Article
Closed access
PDF file
EVEkaterina Vachagina
Ekaterina Vachagina
AZA. Ya. Zolotonosov
A. Ya. Zolotonosov
YZYa. D. Zolotonosov
Ya. D. Zolotonosov
The results of the numerical calculations of isothermal viscous flows in convergent-divergent channels axially rotating at a constant angular velocity are presented. With reference to the example of the calculations performed at Re = 2000 the difference in the flowfields in a fixed channel and that rotating at an angular velocity Ω = 10 s in analyzed. The results of the calculations of viscous flows in convergent-divergent channels at Re = 2000 and Ω = 10 s are also presented.

28 December 2024 in Power engineering: research, equipment, technology
Verified
Journal Article
Open access
PDF file
IKI. A. Krutova
I. A. Krutova
YZYa. D. Zolotonosov
Ya. D. Zolotonosov
RELEVANCE The article is devoted to the development of new designs of heat exchangers and evaluating the efficiency of their operation. According to the authors, currently of particular interest are conical heat exchangers of the "pipe-in-pipe" type, so the object of research in this paper is a heat exchanger in the form of a truncated cone based on a spring-twisted channel. The introduction of the proposed heat exchange elements and apparatuses into the industry requires additional research. To assess the effectiveness of the application of the considered TA, it is proposed to evaluate its performance in comparison with conical and cylindrical TA based on a smooth-walled pipe. Due to this, two hypotheses will be tested at once: the use of a conical coil heat exchanger is more efficient than a cylindrical one, and the replacement of a smooth-walled pipe with a spring-twisted channel increases the efficiency of the heat exchanger.OBJECT. The aim of the research is to develop a method for setting and solving the conjugate heat exchange problem for a heat exchanger in the form of a truncated cone with a heat exchange element in the form of a spring-twisted channel, analyze the results obtained and evaluate the efficiency in comparison with conical and cylindrical heat exchangers based on smooth-walled heat exchange elements. METHODS. For the numerical solution of the conjugate heat transfer problem, the FEM implemented by means of Ansys was used Fluent. RESULTS. The main results consist in the fact that the authors developed a model and algorithm for calculating conical coil heat exchangers of the pipe-in-pipe type, implemented in the Ansys program, and determined the thermal and hydrodynamic parameters of coil devices. A comparison of coil heat exchangers was also made: a conical one based on a spring-twisted channel with a conical one and a cylindrical one with a smooth-walled heat exchange element. The calculation results showed that replacing a smooth-walled pipe with a spring-wound channel significantly increases the efficiency of heat exchange equipment. CONCLUSION. The significance of the obtained results lies in the possibility of using modern, more efficient and compact heat exchange equipment for technological needs and in the justification of this choice. Thus, with equal initial data, conical heat exchangers are more efficient than cylindrical ones with a heat exchange element in the form of a smooth tube, since they need a smaller heat exchange surface to achieve the necessary thermal and hydrodynamic parameters. The results of calculations prove the prospects of using a conical TA based on a spring-twisted channel and show the need for further study of the influence of the geometric characteristics of both the coil itself and the heat exchange element on the thermal and hydrodynamic characteristics of the proposed HE.

1 July 2017 in Fluid Dynamics
Verified
Journal Article
Closed access
PDF file
ABA. G. Bagoutdinova
A. G. Bagoutdinova
EVE. K. Vachagina
E. K. Vachagina
YZYa. D. Zolotonosov
Ya. D. Zolotonosov
A mathematical model of incompressible viscous laminar flow in smooth coil tubes is proposed and the results of its numerical realization in a nonorthogonal helical coordinate system are presented. This coordinate system is free of singularities in the domain of definition of the unknown functions, that is, the pressure and the velocity components, which makes it possible to refine the existing distributions of the axial component and the secondary crossflows obtained using the well-known orthogonal coordinate system having a singularity at the center of the coil channel. The momentum transport equation is written in the projections on the axes of the natural basis of the coordinate system, which makes it possible to subdivide the system of equations into two alternately solved subsystems. The distributions of the axial and two transverse components show that at the center of coil tubes the transverse components are comparable with the axial velocity (the transverse components can be as high as half the mean-flow-rate velocity and one third of it at the center of the channel).



28 March 2026 in Power engineering: research, equipment, technology
Verified
Journal Article
Open access
PDF file
IKI. A. Krutova
I. A. Krutova
YZYa. D. Zolotonosov
Ya. D. Zolotonosov
RELEVANCE . Due to the significant variety of configurations of heat exchange elements and designs of heat exchangers, coefficients of the criterion equation are proposed, which allows for a more accurate comparative evaluation of the efficiency of coil heat exchangers based on springtwisted channels. THE PURPOSE. Carrying out calculations of coil heat exchangers of the "pipe in a pipe" type with a variable bending radius of a helical spiral based on spring-twisted channels and evaluating the energy efficiency of such devices in comparison with smooth-walled analogues. OBJECT of this study is a conical apparatus with coaxially mounted coil tubes. In this case, the inner tube is made in the form of a spring-twisted channel of circular cross-section, and the outer one is made of smooth pipe. METHODS . As part of the work, the engineering calculation of the conical coil apparatus has been adjusted, based on theoretical research and solving the related heat exchange problem, and includes the equations of the modified Ieshke correction factor, criterion equations for calculating heat exchange with heated (hot) and heated (cold) water, and the determination of heat transfer and heat transfer coefficients through the heat exchange surface. RESULTS . In a coil heat exchanger with spring-wound pipes, the temperature of the heated coolant is 8.88°C (60.98°C versus 52.1°C) higher than in smooth-walled pipes. The thermal efficiency of such structures is higher: the power is 25.6 kW at a drop of 20.7°C versus 23.5 kW and 20.4°C, respectively. Heat transfer coefficient of spring-twisted pipes (1543 W/(m2·K)) higher due to turbulence and secondary flows. Hydrodynamic analysis shows a reduction in the cost of pumping heat carriers based on springtwisted channels to 1,438 Watts compared with 1,590 watts for smooth-walled structures. This is due to the shorter required length of the heat exchange element. The superiority of spring-twisted channels is confirmed by a higher value of the Kirpichev criterion (17,83) compared to smoothwalled analogues (14,77), which characterizes their improved energy performance. CONCLUSION . Calculations of coil heat exchangers of the "pipe in a pipe" type with a variable bending radius of the spiral were carried out on the basis of two variants of heat exchange elements: a spring-twisted channel and a smooth pipe, the data obtained are consistent with the results of mathematical modeling. The results of the calculation confirm the technical and energy feasibility of replacing smooth tubes with spring-twisted tubes in the designs of heat exchangers. This modification makes it possible to simultaneously increase the thermal performance of the system and reduce the operational energy consumption for moving the coolant, which leads to a significant increase in the overall energy efficiency of the system. Thus, the use of spring-wound elements in heat exchangers is an innovative solution that improves the efficiency and reliability of heat exchange technology.