Ruibang Sun

Ruibang Sun

Auto-generated profile, based on publicly available information

Ruibang Sun

School of Safety Science

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 November 2021 in ACS Omega
Verified
Journal Article
Open access
RSRuibang Sun
Ruibang Sun
JWJuncai Wang
Juncai Wang
XYXing Yang
Xing Yang
RSRuibang Sun
Ruibang Sun
Under the action of heat, the jet fire of oil-filled equipment in substations produces intense heat radiation and flame impact, causing serious harm to the personnel and equipment. Therefore, this paper has carried out a series of oil-filled equipment transformer oil jet fire experiments with different nozzle diameters to study the characteristics of transformer oil jet flame combustion. The experiment measured the mass loss rate, axial centerline temperature of the fire plume, and radiant heat flux and processed the flame visualization image. The results show that the combustion process of the transformer oil jet fire can be divided into three stages. The functional relationship between the flame height and mass flow and the functional relationship between the flame temperature and axial height are derived. A prediction model of the radiant heat flux of the transformer oil jet fire for the oil-filled equipment of the substation was established. The research results are of great significance for improving the fire protection design of substations and improving fire management and control capabilities.

28 February 2023 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
XZXu Zhai
Xu Zhai
RSRuibang Sun
Ruibang Sun
LLLiyang Li
Liyang Li
RSRuibang Sun
Ruibang Sun
YLYang Liu
Yang Liu
As a traditional fossil fuel, petroleum fuel is prone to spills and fire accidents during storage, transportation, and use, which poses a great threat to the safe utilization of energy. This work aims to study the effect of porous media on the combustion characteristics of continuous spill fires. The transformer oil spill fire experiment is carried out on a porous bed with a length of 120 cm, a width of 15 cm, and a depth of 5 cm. The effects of sand diameter (0.75 mm, 1.5 mm, 3 mm, and 6 mm) and discharge rates (25 ml/min, 50 ml/min, and 75 ml/min) on the development of spill fires are analyzed. The results show that the spill fire fuel transport mechanism mainly includes gas phase diffusion caused by fuel consumption on the surface of a porous bed and liquid phase convection caused by capillary flow. Thus, three zones are formed from top to bottom: (i) the top vapor zone; (ii) the middle gas–liquid two-phase zone; and (iii) the bottom liquid phase zone. The presence of sand reduces the efficiency of the heat and mass. And it makes the spill fire stable combustion area increase compared with the smooth substrate. The stable combustion area has a positive correlation with the mass discharge rate and a negative correlation with the sand size. The stable combustion area of 1.5 mm, 3 mm, and 6 mm sand is 87.1%, 81.9%, and 77.5% of that of the 0.75 mm sand. In contrast to transformer oil pool fires and spill fires on smooth substrates, the burning rate is negatively related to the equivalent burning diameter. Meanwhile, the burning rate of spill fire on porous beds is significantly reduced compared with the first two. Based on the analysis of heat and mass transfer, a model for the burning rate of spill fire in porous media is formed and its correctness is verified. The experimental results are of great significance to the safe utilization of liquid energy.

18 December 2021 in Combustion Science and Technology
Verified
Journal Article
Closed access
RSRuibang Sun
Ruibang Sun
XYXing Yang
Xing Yang
JWJuncai Wang
Juncai Wang
RSRuibang Sun
Ruibang Sun
In this paper, a series of transformer oil jet fire experiments with different tanks of inner diameters (0.05 m/0.08 m/0.1 m), different filling rate (80%/100%) and different pool diameters (0.3 m/0.4 m) were carried out to study the radiation characteristics of transformer oil jet fire. The flame combustion characteristics such as the fire plume temperature, mass loss and radiant heat flux were measured and analyzed. The experimental results showed that: The shape of the transformer oil jet fire was approximately cylindrical. The radiant heat flux increased exponentially with the increased of flame height. And radiant heat flux decreased exponentially as the horizontal distance increased. The multi-point source model and the line source model performed well in the prediction of the fire radiant heat flux of the transformer oil jet. As the Froude number increased, the radiation fraction change could be divided into two stages. In the first stage, the radiation fraction maintained almost constant. In the second stage, the radiation fraction dropped significantly. The research results provided valuable data support for the fire protection design of substation equipment. In addition, it could effectively improve the fire prevention and control ability of substation personnel.

22 June 2022 in ACS Omega
Verified
Journal Article
Open access
RSRuibang Sun
Ruibang Sun
RSRuibang Sun
Ruibang Sun
LLLiyang Li
Liyang Li
YLYang Liu
Yang Liu
XZXu Zhai
Xu Zhai
Transformer oil jet fire is one of the most dangerous types of fires in substations. The combustion behavior of transformer oil jet fire produces uncontrollable hazards to personnel and equipment and even triggers a domino effect. However, the jet fire combustion behavior of such materials as transformer oil has not been revealed before. Investigation of the combustion behavior of transformer oil jet fire has positive implications for the prevention and control of substation fires. In this paper, KI25X transformer oil was used as fuel. A series of transformer oil jet fire experiments were conducted with variable orifice diameters (5, 10, and 15 mm) with heat release rates ranging from 200 to 659.2 kW. The results showed that the entrainment coefficient of transformer oil jet fire was greater than that of pure gas phase jet fire. The entrainment coefficient of transformer oil jet fire was 0.029. Using dimensionless theory, it was proposed that the imaginary point source was proportional to the 0.317 power of Froude number. Based on the point source model, a dimensional analysis model with Reynolds number was developed. The radiation fraction of transformer oil jet fire was proportional to the -0.133 power of Reynolds number. This study played an important role in improving the jet combustion behavior of transformer oil.

8 May 2025 in ACS Omega
Verified
Journal Article
Open access
RSRuibang Sun
Ruibang Sun
CLChang Liu
Chang Liu
PLPeng Li
Peng Li
XZXinwei Zhang
Xinwei Zhang
FSFengju Shang
Fengju Shang
Transformer jet fire is one of the most serious types of substation fire accidents, which often causes heavy casualties and property losses and even causes other secondary disasters, further expanding the impact of thermal disasters. Compared with the jet fire formed by the leakage of gaseous combustibles during production, transportation, and storage, the research on the combustion behavior of transformer jet fire under multiple factors, such as flame shape and flame height, is relatively scarce. This study used the research method of combining experimental research with theoretical analysis. Flame shape and flame height of transformer jet fire under different vessel diameters (5, 8, and 10 cm), opening diameters (5, 10, and 15 mm), and filling rate (60, 80, and 100%) were measured and analyzed. The results show that jet momentum and flame buoyancy are the main reasons for the change in flame shape characteristics. The transformer jet fire development process can be divided into three typical stages of full development, stable jet, decay, and extinguish. The flame height increases with the increase of the opening diameter and container diameter, and increases first and then decreases with the increase of filling rate. The functional relationship between the flame height and the 0.2 power of the characteristic Froude number is established. The research results provide reliable theoretical guidance and data support for transformer fire prevention and control.

13 October 2021 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
RSRuibang Sun
Ruibang Sun
JWJuncai Wang
Juncai Wang
XYXing Yang
Xing Yang
PCPeng Chen
Peng Chen
LWLiusuo Wu
Liusuo Wu
The transformer oil jet fire accidents caused by the failure in the substation may cause significant economic losses. In this study, the geometric characteristics of transformer oil jet fire are studied by conducting experiments with different variable conditions. In this regard, CCD images and infrared images of jet flame are tested and analyzed under different diameter nozzles and different diameter containers. The obtained results show that the temperature boundary of jet flame varies in the range of 600 K ~ 700 K. The flame geometry can be approximated as a cylinder. Moreover, it is found that the heat release rate is a function of the flame height to the power of 2/5. When the Froude number is 1.5 × 106, the flame governing mechanism from the buoyancy main control to the momentum main control. Flame width increases significantly as the heat release rate increases. The heat release rate is a function of the flame width to the power of 1/3. Furthermore, the flame volume is related to the 0.85 power of the heat release rate. The obtained results, are of great significance to improve the analysis capability of jet fire hazard, and prevent the control ability of transformer oil jet fire accidents in substations.