Ruolun Zhang

Ruolun Zhang

Auto-generated profile, based on publicly available information

Ruolun Zhang

Department of Physics, University of California, San Diego, CA 92093, USA

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2009 in Solid State Communications
Verified
Journal Article
Closed access
ZZZ. Zhang
Z. Zhang
RZR. Zhang
R. Zhang
ZXZ.L. Xie
Z.L. Xie
Bin LiuBin Liu
Bin Liu
MLMei Li
Mei Li
ZWZ.G. Wang
Z.G. Wang

11 October 2004 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
JLJ. Lu
J. Lu
Bo ShenBo Shen
Bo Shen
Ning TangNing Tang
Ning Tang
DCD. J. Chen
D. J. Chen
HZHuijuan Zhao
Huijuan Zhao
YAY. Arakawa
Y. Arakawa
Weak anti-localization of the two-dimensional electron gas (2DEG) in a modulation-doped Al0.22Ga0.78N∕GaN single heterostructure has been investigated through magnetoresistance measurements at low temperatures. The elastic scattering time τe , dephasing time τϕ and spin-orbit scattering time τso at various temperatures are obtained. When the second subband in the triangular quantum well at the heterointerface is occupied by the 2DEG, the weak anti-localization is observed clearly, which is thought to be due to the strong spin-orbit effect induced by the intersubband scattering. The spin-orbit effect and the intersubband scattering become stronger with increasing temperature.

21 February 2010 in Superlattices and Microstructures
Verified
Journal Article
Closed access
MLMei Li
Mei Li
RZR. Zhang
R. Zhang
ZZZ. Zhang
Z. Zhang
YWYan wenqin
Yan wenqin
Bin LiuBin Liu
Bin Liu
YZY.D. Zheng
Y.D. Zheng

1 September 2023 in Review of Scientific Instruments
Verified
Journal Article
Open access
PDF file
LCLeonard Weihao Cao
Leonard Weihao Cao
CWChen Wu
Chen Wu
RBRajarshi Bhattacharyya
Rajarshi Bhattacharyya
RZRuolun Zhang
Ruolun Zhang
MAMonica T. Allen
Monica T. Allen
Microwave impedance microscopy (MIM) is a near-field imaging technique that has been used to visualize the local conductivity of materials with nanoscale resolution across the GHz regime. In recent years, MIM has shown great promise for the investigation of topological states of matter, correlated electronic states, and emergent phenomena in quantum materials. To explore these low-energy phenomena, many of which are only detectable in the milliKelvin regime, we have developed a novel low-temperature MIM incorporated into a dilution refrigerator. This setup, which consists of a tuning-fork-based atomic force microscope with microwave reflectometry capabilities, is capable of reaching temperatures down to 70 mK during imaging and magnetic fields up to 9 T. To test the performance of this microscope, we demonstrate microwave imaging of the conductivity contrast between graphite and silicon dioxide at cryogenic temperatures and discuss the resolution and noise observed in these results. We extend this methodology to visualize edge conduction in Dirac semi-metal cadmium arsenide in the quantum Hall regime.

7 August 2026 in Science Advances
Verified
Journal Article
Closed access
QZQixuan Zhang
Qixuan Zhang
LLLingyuan Lyu
Lingyuan Lyu
SPSneh Pancholi
Sneh Pancholi
ZYZiying Yan
Ziying Yan
TSTrevor Senaha
Trevor Senaha
MAMonica T. Allen
Monica T. Allen
Moiré superlattices in stacked two-dimensional crystals are powerful platforms for engineering correlated and topological quantum phases, with twisted graphene and transition metal dichalcogenides as prominent examples. Their angle-sensitive band structures enable rich tunability; however, conventional tear-and-stack methods fix the angle at assembly, limiting systematic exploration of angle-dependent phenomena. Here, we present a scanning probe–based manipulation scheme that enables in situ, continuous postfabrication twist control using nanostructured metal rotors. We demonstrate reproducible angle tuning and direct moiré imaging across three platforms: graphene, hexagonal boron nitride, and encapsulated, air-sensitive MoTe 2 . Quantitative piezoresponse force microscopy analysis confirms subdegree precision with minimal induced heterostrain, preserving sample quality even in the marginally twisted regime. Crucially, the device architecture maintains open access to the active region, allowing optical, scanning probe, and transport measurements. This work enables single-device mapping of the angular phase diagram of moiré material including the minimally twisted regime.