Gravity is omnipresent on Earth; however, humans in space, such as astronauts at the International Space Station, experience microgravity. Long-term exposure to microgravity is considered to elicit physiological changes, such as muscle atrophy, in the human body. In addition, certain types of cancer cells demonstrate inhibited proliferation under condition of time-averaged simulated microgravity (taSMG). However, the response of human Hodgkin’s lymphoma cancer cells to reduced gravity, and the associated physiological changes in these cells, have not been elucidated. In this study, the proliferation of human Hodgkin’s lymphoma cancer cells (L-540 and HDLM-2) under taSMG condition (<10−3 G, 1 G is defined as 9.8 m/s2) was studied using a 3D clinostat. Normal human dermal fibroblast (HDF) was proliferated in the same condition as a control group. For the development of 3D clinostat, two motors were used to actuate the frames. Electrical wires for power supply and communication were connected via slip ring. For symmetrical path of gravitational vector, optimal angular velocities of the motors were found using simulation results. Under the condition of taSMG implemented by the 3D clinostat, proliferation of the cells was observed for 3 days. The results indicated that proliferation of these cancer cells was significantly (p < 0.0005) inhibited under taSMG, whereas proliferation of normal HDF cells was not affected. Findings in this study could be significantly valuable in developing novel strategies for selective killing of cancer cells such as lymphoma.
1 February 2017 in The American Journal of Emergency Medicine
In the context of stroke rehabilitation, simple structures and user-intent driven actuation are relevant features to facilitate neuroplasticity as well as deliver a sufficient number of repetitions during a single therapy session. A novel robotic treatment device for distal upper limb rehabilitation in stroke patients was developed, and a usability test was performed to assess its clinical feasibility. The rehabilitation robot was designed as a two-axis exoskeleton actuated by electric motors, consisting of forearm supination/pronation and hand grasp/release, which were selected based on a kinematic analysis of essential daily activities. A vision-assisted algorithm was utilized for user-intent extraction in a human-in-the-loop concept. A usability test was performed on six physiatrists, five biomedical engineers, five rehabilitation therapists, two chronic stroke patients, and two caregivers of the patients. After sufficient instruction, all subjects tested the robot for a minimum of 10 min and completed the evaluation form using a 7-point Likert scale. The participants found the device interesting (5.7 ± 1.2), motivating (5.8 ± 0.9), and as having less possibility of causing injury or safety issues (6.1 ± 1.1); however, the appropriateness of difficulty (4.8 ± 1.9) and comfort level (4.9 ± 1.3) were found to be relatively low. Further development of the current device would provide a good treatment option as a simple, low-cost, and clinically feasible rehabilitation robot for stroke.
1 January 2015 in Journal of Korean Medical Science