Thomas Schönau

Thomas Schönau

Auto-generated profile, based on publicly available information

Thomas Schönau

Leibniz Institute of Photonic Technology , Albert-Einstein-Strasse 9, D-07745 Jena

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 February 2025 in Physical Review Applied
Verified
Journal Article
Open access
TSThomas Schönau
Thomas Schönau
TSTheo Scholtes
Theo Scholtes
FWFlorian Wittkämper
Florian Wittkämper
ASAlexander Sekels
Alexander Sekels
SHStefan Hiebel
Stefan Hiebel
RSRonny Stolz
Ronny Stolz
We present an approach allowing an optically pumped magnetometer (OPM) to be operated within the Earth’s magnetic field as a vector magnetometer, the sensitive axis of which can be freely defined. This approach enables the measurement of any vector component of the Earth’s magnetic field with the same sensitivity. The OPM is realized by a microfabricated cesium-vapor cell with nitrogen buffer gas, which is immersed in a constant homogeneous bias field of approximately 730 μ T . Since this bias field is about one order of magnitude stronger than the Earth’s magnetic field, it defines the sensitive axis of the OPM. The bias field is generated by solid-state magnets and has been designed to exhibit a very low relative inhomogeneity ( < ± 10 − 4 in relative units) within the vapor-cell dimensions as well as a point of vanishing temperature dependence at around 40 ∘ C . The OPM utilizes the light-narrowing effect, which enables effective suppression of spin-exchange relaxation even in such a large magnetic field amplitude. Based on this implementation, we demonstrate a white-noise floor of below 60 fT / Hz in the frequency interval between 100 Hz and 600 Hz and a 3-dB sensor bandwidth of > 5 kHz . Our approach enables unshielded ultrasensitive vectorial measurement capabilities that are relevant in many important applications.

5 December 2011 in Superconductor Science and Technology
Verified
Journal Article
Closed access
TST Schönau
T Schönau
MSM Schmelz
M Schmelz
VZV Zakosarenko
V Zakosarenko
RSRonny Stolz
Ronny Stolz
SAS Anders
S Anders
HMH-G Meyer
H-G Meyer

13 December 2018 in Superconductor Science and Technology
Verified
Journal Article
Closed access
PDF file
VZVyacheslav Zakosarenko
Vyacheslav Zakosarenko
MSMatthias Schmelz
Matthias Schmelz
TST Schönau
T Schönau
SASolveig Anders
Solveig Anders
JKJuergen Kunert
Juergen Kunert
TSThomas Stoehlker
Thomas Stoehlker
We report on a novel concept and prototype development of a coreless SQUID-based charged-particle beam monitor as a non-destructive diagnostic tool for accelerator facilities. Omitting the typically used pickup coil with a high magnetic permeability core leads to a significant improvement in low-frequency noise performance. Moreover, a revised shielding geometry allows for very compact and rather lightweight device designs. Based on highly sensitive SQUIDs featuring sub-micron cross-type Josephson tunnel junctions, our prototype device exhibits a current sensitivity of about 6 pA Hz −1/2 in the white noise region. Together with a measured shielding factor of about 135 dB this opens up the way for its widespread use in modern accelerator facilities.

27 March 2015
Verified
Conference Paper
Closed access
PDF file
RSR. Stolz
R. Stolz
MSM. Schiffler
M. Schiffler
MQM. Queitsch
M. Queitsch
TST. Schönau
T. Schönau
MSM. Schmelz
M. Schmelz
HMH.-G. Meyer
H.-G. Meyer

19 January 2018 in Superconductor Science and Technology
Verified
Journal Article
Closed access
PDF file
TST Schönau
T Schönau
VZVyacheslav Zakosarenko
Vyacheslav Zakosarenko
MSMatthias Schmelz
Matthias Schmelz
SASolveig Anders
Solveig Anders
HMHans-Georg Meyer
Hans-Georg Meyer
TSThomas Schoenau
Thomas Schoenau
The effect of flux trapping on the flux-voltage characteristics of multi-loop SQUID magnetometers was investigated by means of repeated cool-down cycles in a stepwise increased magnetic background field. For a SQUID with N parallel loops, N different flux offsets, each separated by Φ 0 / N , were observed even in zero magnetic field. These flux offsets further split into a so called fine structure, which can be explained by minor asymmetries in the SQUID design. The observed results are discussed with particular regard to their impact on the previously presented absolute SQUID cascade vector magnetometer.

27 March 2024 in bioRxiv
Verified
Preprint
Open access
PDF file
VDValentin Dunsing-Eichenauer
Valentin Dunsing-Eichenauer
JHJohan Hummert
Johan Hummert
CCClaire Chardès
Claire Chardès
TSThomas Schönau
Thomas Schönau
LGLéo Guignard
Léo Guignard
PLPierre-François Lenne
Pierre-François Lenne
Fluorescence lifetime imaging (FLIM) is widely used for functional and multiplexed bioimaging. The lifetime of autofluorescence or fluorescent sensors encodes physiologically relevant parameters. Thus, FLIM is especially relevant for the investigation of living systems. However, application of FLIM to live specimen is hampered by its slow speed and high phototoxicity. To enable faster and gentler FLIM, we integrated single-objective light-sheet microscopy with pulsed excitation and time-resolved detection on a novel SPAD array detector. We achieved 10-100-fold acceleration compared to confocal FLIM, down to 100 ms acquisition time per image, with excellent quantitative agreement. The massively enhanced speed enables volumetric FLIM acquisitions on live multicellular specimens, which we demonstrate with lifetime-based multiplexing in 3D and time-lapse FLIM of tension probes on living embryonic organoids. We benchmark both scanned and static light-sheet modalities to facilitate adding FLIM capability to a large variety of light-sheet microscopes.