20 July 2023 in IEEE Transactions on Medical Imaging
Magnetic particle imaging (MPI) is an emerging technique for determining magnetic nanoparticle distributions in biological tissues. Although system-matrix (SM)-based image reconstruction offers higher image quality than the X-space-based approach, the SM calibration measurement is time-consuming. Additionally, the SM should be recalibrated if the tracer’s characteristics or the magnetic field environment change, and repeated SM measurement further increase the required labor and time. Therefore, fast SM calibration is essential for MPI. Existing calibration methods commonly treat each row of the SM as independent of the others, but the rows are inherently related through the coil channel and frequency index. As these two elements can be regarded as additional multimodal information, we leverage the transformer architecture with a self-attention mechanism to encode them. Although the transformer has shown superiority in multimodal fusion learning across several fields, its high complexity may lead to overfitting when labeled data are scarce. Compared with labeled SM (i.e., full size), low-resolution SM data can be easily obtained, and fully using such data may alleviate overfitting. Accordingly, we propose a pseudo-label-based progressive pretraining strategy to leverage unlabeled data. Our method outperforms existing calibration methods on a public real-world OpenMPI dataset and simulation dataset. Moreover, our method improves the resolution of two in-house MPI scanners without requiring full-size SM measurements. Ablation studies confirm the contributions of modeling SM inter-row relations and the proposed pretraining strategy.
4 January 2023 in IEEE Transactions on Biomedical Engineering
Objective: Magnetic particle imaging (MPI) is a promising medical modality that can image superparamagnetic iron-oxide nanoparticle (SPIO) concentration distributions safely and with high sensitivity. In the x-space reconstruction algorithm, the Langevin function is inaccurate in modeling the dynamic magnetization of SPIOs. This problem prevents the x-space algorithm from achieving a high spatial resolution reconstruction. Methods: We propose a more accurate model to describe the dynamic magnetization of SPIOs, named the modified Jiles–Atherton (MJA) model, and apply it to the x-space algorithm to improve the image resolution. Considering the relaxation effect of SPIOs, the MJA model generates the magnetization curve via an ordinary differential equation. Three modifications are also introduced to further improve its accuracy and robustness. Results: In magnetic particle spectrometry experiments, the MJA model shows higher accuracy than the Langevin and Debye models under various test conditions. The average root-mean-square error is 0.055, 83% and 58% lower than the Langevin and Debye models, respectively. In MPI reconstruction experiments, the MJA x-space improves the spatial resolution by 64% and 48% compared to the x-space and Debye x-space methods, respectively. Conclusion: The MJA model shows high accuracy and robustness in modeling the dynamic magnetization behavior of SPIOs. By integrating the MJA model into the x-space algorithm, the spatial resolution of MPI technology was improved. Significance: Improving the spatial resolution by using the MJA model helps MPI have a better performance in medical fields, including cardiovascular imaging.
1 June 2023 in IEEE Magnetics Letters
The purpose of this study is to develop magnetic particle imaging (MPI) technique in directly measuring time-varied cerebral superparamagnetic iron oxide nanoparticles (SPIOs) concentration in rhesus macaque. A hand-held MPI detector was developed to monitor MPI signal changes at the third harmonics of the drive frequency in resting-state nonhuman primates. Phantom experiments were firstly performed to determine the sensitivity limits of the detector as a function of distance from the detector and SPIOs concentration. Measured sensitivity profile was then used to reveal the most sensitive region of the detector. MPI detection was continuously performed to monitor MPI signal changes after two bolus injections of SPIOs in the rhesus macaque. We successfully developed a hand-held MPI to detect cerebral SPIO concentration changes in living nonhuman primate. The detection limit of the MPI detector is about 125 ng iron. We reported on the first in vivo measurement of cerebral SPIO concentration changes in rhesus macaque using a hand-held MPI detector. In vivo experiments showed the feasibility of the detector to sensitively measure MPI signals in nonhuman primate brain.
24 June 2024 in IEEE Transactions on Instrumentation and Measurement
Magnetic particle imaging (MPI) is a burgeoning imaging modality that facilitates the reconstruction of position and concentration of superparamagnetic iron oxide nanoparticles. Its potential in clinical applications is substantial, leading to an increasing demand for larger bore sizes in MPI systems. However, the challenge lies in maintaining high resolution, sensitivity, and real-time imaging advantages in larger systems. In this article, we present the design of a three-dimensional (3D) MPI system tailored for non-human primates (NHP-MPI) with a bore size of 190 mm. The application of a 3D digital-scanned focus field is applied to obtain highly sensitive imaging, and the system operates cooling-free under low gradient conditions. In imaging experiments involving a macaque’s brain, our system demonstrated good quantitative performance. The 3D MPI image yielded satisfactory results for fusion with other structural imaging modalities.
9 June 2023 in Medical Physics
25 July 2023 in IEEE Transactions on Instrumentation and Measurement
Magnetic particle spectrometer (MPS) is the device for characterizing the properties of magnetic nanoparticle (MNP) suspensions, such as viscosity, temperature, and concentration. Specifically, in viscosity measurement, MPS usually works at one or several fixed frequencies. It is challenging to find the appropriate frequency for viscosity measurement of different MNP suspensions. The frequency parameter can be introduced into the measurement method to improve the measurement accuracy. Here, we developed an arbitrary frequency MPS to measure the harmonic amplitudes of the magnetization signals of MNPs, which were generated at various frequencies. A method of measuring the viscosity of MNP suspensions by harmonic ratios at different frequencies was proposed. The viscosity measurement time used in the experiment is 1 s, and the shortest measurement time available is 0.2 s. Experimental results show that the arbitrary frequency MPS can be used to measure viscosities ranging from 0.77 mPa·s to 3.87 mPa·s, and the average measurement deviation is 2.7%. The method was validated using plasma samples from normal rabbits and high-fat diet (HFD) rabbits. Normal rabbit measurements differed from the reference by less than 4.5%, and the plasma viscosity of normal and HFD rabbits could be clearly distinguished.