Sukhdeep Singh Dhami

Sukhdeep Singh Dhami

Auto-generated profile, based on publicly available information

Sukhdeep Singh Dhami

Department of Mechanical Engineering, National Institute of Technical Teachers Training and Research, Chandigarh 160019, India

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 January 2021 in Journal of Nondestructive Evaluation, Diagnostics and Prognostics of Engineering Systems
Verified
Journal Article
Closed access
PDF file
DGDeepam Goyal
Deepam Goyal
SDS. S. Dhami
S. S. Dhami
BPB. S. Pabla
B. S. Pabla
Accelerometers, used as vibration pickups in machine health monitoring systems, need physical connection to the machine tool through cables, complicating physical systems. A non-contact laser based vibration sensor has been developed and used for bearing health monitoring in this article. The vibration data have been acquired under speed and load variation. Hilbert transform (HT) has been applied for denoising the vibration signal. An extraction of condition monitoring indicators from both raw and envelope signals has been made, and the dimensionality of these extracted indicators was deducted with principal component analysis (PCA). Sequential floating forward selection (SFFS) method has been implemented for ranking the selected indicators in order of significance for reduction in the input vector size and for finalizing the most optimal indicator set. Finally, the selected indicators are passed to k-nearest neighbor (kNN) and weighted kNN (WkNN) for diagnosing the bearing defects. The comparative analysis of the effectiveness of kNN and WkNN has been executed. It is evident from the experimental results that the vibration signals obtained from developed non-contact sensor compare adequately with the accelerometer data obtained under similar conditions. The performance of WkNN has been found to be slower compared to kNN. The proposed fault detection methodology compares very well with the other reported methods in the literature. The non-contact fault detection methodology has an enormous potential for automatic recognition of defects in the machine, which can provide early signals to avoid catastrophic failure and unplanned equipment shutdowns.

8 June 2016 in Neural Computing and Applications
Verified
Journal Article
Closed access
PDF file
DGDeepam Goyal
Deepam Goyal
BPB. S. Pabla
B. S. Pabla
SDS. S. Dhami
S. S. Dhami
KLKailash Lachhwani
Kailash Lachhwani

3 August 2023 in Journal of the Mechanical Behavior of Biomedical Materials
Verified
Journal Article
Closed access
PJPrashant Jindal
Prashant Jindal
JBJogendra Bharti
Jogendra Bharti
VGVipin Gupta
Vipin Gupta
SDS.S. Dhami
S.S. Dhami

16 February 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
MJMamta Juneja
Mamta Juneja
ISIshaan Singla
Ishaan Singla
APAditya Poddar
Aditya Poddar
NPNitin Pandey
Nitin Pandey
AGAparna Goel
Aparna Goel
PBPhilip Breedon
Philip Breedon
Cranioplasty enables the restoration of cranial defects caused by traumatic injuries, brain tumour excisions, or decompressive craniectomies. Conventional methods rely on Computer-Aided Design (CAD) for implant design, which requires significant resources and expertise. Recent advancements in Artificial Intelligence (AI) have improved Computer-Aided Diagnostic systems for accurate and faster cranial reconstruction and implant generation procedures. However, these face inherent limitations, including the limited availability of diverse datasets covering different defect shapes spanning various locations, absence of a comprehensive pipeline integrating the preprocessing of medical images, cranial reconstruction, and implant generation, along with mechanical testing and validation. The proposed framework incorporates a robust preprocessing pipeline for easier processing of Computed Tomography (CT) images through data conversion, denoising, Connected Component Analysis (CCA), and image alignment. At its core is CRIGNet (Cranial Reconstruction and Implant Generation Network), a novel deep learning model rigorously trained on a diverse dataset of 2160 images, which was prepared by simulating cylindrical, cubical, spherical, and triangular prism-shaped defects across five skull regions, ensuring robustness in diagnosing a wide variety of defect patterns. CRIGNet achieved an exceptional reconstruction accuracy with a Dice Similarity Coefficient (DSC) of 0.99, Jaccard Similarity Coefficient (JSC) of 0.98, and Hausdorff distance (HD) of 4.63 mm. The generated implants showed superior geometric accuracy, load-bearing capacity, and gap-free fitment in the defected skull compared to CAD-generated implants. Also, this framework reduced the implant generation processing time from 40–45 min (CAD) to 25–30 s, suggesting its application for a faster turnaround time, enabling decisive clinical support systems.

11 April 2023 in Materials Today: Proceedings
Verified
Journal Article
Closed access
JBJogendra Bharti
Jogendra Bharti
SDSukhdeep Singh Dhami
Sukhdeep Singh Dhami

1 January 2022
Verified
Book Chapter
Closed access
PDF file
RBRahul Bansal
Rahul Bansal
SDSukhdeep Singh Dhami
Sukhdeep Singh Dhami
JMJatinder Madan
Jatinder Madan