Esther Borrás

Esther Borrás

Auto-generated profile, based on publicly available information

Esther Borrás

Fundación Centro de Estudios Ambientales del Mediterráneo (CEAM), 46980 Paterna, Valencia, Spain

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 January 2012 in International Journal of Environmental Analytical Chemistry
Verified
Journal Article
Closed access
EBEsther Borrás
Esther Borrás
Luis Antonio Tortajada-GenaroLuis Antonio Tortajada-Genaro
Luis Antonio Tortajada-Genaro
The determination of multifunctional oxygenated compounds in secondary organic aerosols (SOA) usually requires a derivatisation protocol prior to gas chromatography-mass spectrometry analysis (GC-MS). Our proposed protocol, a combination of O-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine (PFBHA) plus diluted N-methyl-N-trimethyl-silyltrifluoroacetamide (MSTFA) without catalyst, has improved the determination of carbonyls, polyhydroxyl-compounds, hydroxyl-carbonyls, hydroxyl-carboxylic acids and di-carboxylic acids. The optimised derivatisation protocol has been successfully used for blanks, standard mixtures and photo-oxidation products from isoprene and toluene generated in a high-volume simulation chamber (European Photoreactor, EUPHORE). Some previously identified degradation products for isoprene including tetrols such as threitol, erythritol; 2-methyltetrols and 2-methylglyceric acid; and for toluene including nitrophenols, methyl-nitrophenols, benzaldehyde, p-cresol, benzoic acid, glyoxylic acid and methyl-glyoxylic acid, have been identified in our aerosol samples, thus confirming the successful applicability of the proposed derivatisation protocol. Moreover, the reduction of artefacts and enhanced signal-to-noise ratio, have allowed us to extend the number of multifunctional compounds determined. These findings have demonstrated the validity of this analytical strategy, which will contribute to a better understanding of the atmospheric degradation chemistry of biogenic and anthropogenic pollutants.


1 February 2016 in Talanta
Verified
Journal Article
Open access
EBEsther Borrás
Esther Borrás
Luis Antonio Tortajada-GenaroLuis Antonio Tortajada-Genaro
Luis Antonio Tortajada-Genaro
AMAmalia Muñoz
Amalia Muñoz
A reliable method for determining malodorous reduced sulfur compounds (RSC) in atmospheric samples has been developed. The method uses an activated coconut solid-phase sorbent for active sampling, hexane as desorption solvent, and gas chromatography-mass spectrometry (GC-MS) technique for specific and sensitive separation-detection. The compounds analyzed were hydrogen sulfide, ethyl mercaptan, dimethyl sulfide, carbon disulfide, butyl mercaptan and dimethyl disulfide. Recovery efficiency varied between 75% and 97% and no detectable losses were observed during storage at -20°C. Satisfactory analytical parameters were reported, such as good linearity (r(2)>0.98), low detection limits (0.6-59 pg m(-3)), adequate repeatability (9%) and reproducibility (17%), and fast GC-MS analysis (<6.5 min). The accurate determination of RSCs, free of interferences from atmospheric components, such as ozone or water was demonstrated. The method has been applied to analyze the composition of environmental air close to three landfills processing urban and industrial solid wastes. The results indicated that hydrogen sulfide and ethyl mercaptan were the main molecules responsible of malodor phenomenon in the study areas.

1 November 2015 in Chemosphere
Verified
Journal Article
Open access
EBEsther Borrás
Esther Borrás
Luis Antonio Tortajada-GenaroLuis Antonio Tortajada-Genaro
Luis Antonio Tortajada-Genaro
MGMILA RÓDENAS GARCÍA
MILA RÓDENAS GARCÍA
TVTeresa Vera
Teresa Vera
CCClara Coscollà
Clara Coscollà
AMAmalia Muñoz
Amalia Muñoz
The phosphorothioate structure is highly present in several organophosphorus pesticides. However, there is insufficient information about its degradation process after the release to the atmosphere and the secondary pollutants formed. Herein, the atmospheric reaction of chlorpyrifos-methyl (o,o-dimethyl o-(3,5,6-trichloropyridin-2-yl) phosphorothioate), is described for semi-urban or rural locations. The photo-oxidation under low NOx conditions (5-55 ppbV) was reproduced in a large outdoor simulation chamber, observing a rapid degradation (lifetime<3.5 h). The formation of gaseous products and particulate matter (aerosol yield 2-8%) was monitored. The chemical composition of minor products (gaseous and particulate) was studied, identifying 15 multi-oxygenated derivatives. The most abundant products were ring-retaining molecules such as o,o-dimethyl o-(3,5,6-trichloropyridin-2-yl) phosphorothioate, dimethyl 3,5,6-trichloropyridin-2-yl phosphate, o-methyl o-(3,5,6-trichloropyridin-2-yl) hydrogen phosphorothioate, 3,5,6-trichloropyridin-2-yl dihydrogen phosphate, 3,5,6-trichloropyridin-2-ol, and 3,5,6-trichloropyridine-2,4-diol. An atmospheric degradation mechanism has been proposed based on an oxidation started with OH-nucleophilic attack to P=S bond. The results have been extrapolated to other organothiophosphorus molecules, such as malathion, parathion, diazinon and methidathion, among many others, to estimate their photo-oxidative degradation and the expected products.

19 July 2021 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
EBEsther Borrás
Esther Borrás
Luis Antonio Tortajada-GenaroLuis Antonio Tortajada-Genaro
Luis Antonio Tortajada-Genaro
MGMILA RÓDENAS GARCÍA
MILA RÓDENAS GARCÍA
TVTeresa Vera
Teresa Vera
TSThomas Speak
Thomas Speak
AMAmalia Muñoz
Amalia Muñoz
Multi-oxygenated volatile organic compounds are important markers of air pollution and precursors of ozone and secondary aerosols in both polluted and remote environments. Herein, their accurate determination was enhanced. The approach was based on an automated system for active sampling and on-fibre derivatization coupled with the gas chromatography–mass spectrometry (GC–MS) technique. The method capability was determined for different compound families, such as aldehydes, ketones, α-dicarbonyls, hydroxy-aldehydes, hydroxy-ketones, and carboxylic acids. A good accuracy (<7 %) was demonstrated from the results compared to Fourier-transform infrared spectroscopy (FTIR). Limits of detection (LODs) of 6–100 pptV were achieved with a time resolution lower than 20 min. The developed method was successfully applied to the determination of multi-oxygenated compounds in air samples collected during an intercomparison campaign (EUROCHAMP-2020 project). Also, its capability and accuracy for atmospheric monitoring was demonstrated in an isoprene ozonolysis experiment. Both were carried out in the high-volume outdoor atmospheric simulation chambers (EUPHORE, 200 m3). In summary, our developed technique offers near-real-time monitoring with direct sampling, which is an advantage in terms of handling and labour time for a proper quantification of trace levels of atmospheric multi-oxygenated compounds.

31 July 2024 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
FLFinja Löher
Finja Löher
EBEsther Borrás
Esther Borrás
AMAmalia Muñoz
Amalia Muñoz
ANAnke Nölscher
Anke Nölscher
The photooxidation of volatile organic compounds (VOCs) in the troposphere has important implications for air quality, weather, and climate. A deeper understanding of the underlying mechanisms can be achieved by studying these reactions under controlled conditions and analysing the emerging photooxidation products. This requires dedicated laboratory infrastructure as well as sensitive and selective analytical techniques. Here, we constructed a new 300 L indoor Teflon atmospheric simulation chamber as part of the Bayreuth ATmospheric simulation CHambers (BATCH) infrastructure. The chamber was irradiated by a bandpass-filtered solar simulator that enabled experiments with realistic photon fluxes and OH radical concentrations. It was coupled to a proton-transfer-reaction time-of-flight mass spectrometer (PTR-ToF-MS) and a solid-phase microextraction–gas chromatography–mass spectrometry (SPME-GC-MS) system for the on-line analysis of the precursor VOC and its oxidation products in the gas phase. As part of the SPME-GC-MS method, multifunctional oxygenated compounds (carbonyls, alcohols, carboxylic acids) were derivatized with O-(2,3,4,5,6-pentafluorobenzyl)hydroxylamine (PFBHA) and N-trimethylsilyl-N-methyltrifluoroacetamide (MSTFA). We designed a permeation source for the on-line addition of internal standards to improve method reproducibility. The joint setup was tested and validated by studying the OH-radical-induced photooxidation of toluene, one of the most abundant aromatic hydrocarbons in the atmosphere. For chamber characterization, we first derived the photolysis rates for several typical toluene products in the irradiated BATCH Teflon chamber (1.77 × 10−8–3.02 × 10−4 s−1). Additionally, wall loss rates were determined empirically (4.54 × 10−6–8.53 × 10−5 s−1) and then parameterized according to fundamental molecular properties. For the cresols, we compiled a weighted calibration factor for the PTR-ToF-MS, taking into account isomer-specific sensitivities as well as the relative distribution as determined by the SPME-GC-MS. The weighted calibration improved the instrumental agreement to 14 %, whereas the PTR-ToF-MS overestimated the sum of the isomers by 31 % compared to the SPME-GC-MS concentrations when using the averaged calibration factor. Thus, the combined data set offered insight into both temporal trends and the isomeric composition. Finally, we conducted six toluene photooxidation experiments to evaluate the ring-retaining first-generation products. Based on the loss-corrected concentrations, we derived formation yields for o-cresol (8.0 ± 1.8 %), m-cresol (0.4 ± 0.1 %), p-cresol (2.4 ± 0.6 %), benzyl alcohol (0.5 ± 0.1 %), and benzaldehyde (4.6 ± 1.7 %) under NOx-free conditions at T = 298 ± 1 K. These yields are consistent with previous studies and therefore serve as proof of concept for our applied methods.