Qi Chen

Qi Chen

Auto-generated profile, based on publicly available information

Qi Chen


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 September 2022 in Sensors
Verified
Journal Article
Open access
PDF file
YWYiwei Wu
Yiwei Wu
KTKuan Tao
Kuan Tao
QCQi Chen
Qi Chen
Fei WangFei Wang
Fei Wang
LSLixin Sun
Lixin Sun
The Perception Neuron Studio (PNS) is a cost-effective and widely used inertial motion capture system. However, a comprehensive analysis of its upper-body motion capture accuracy is still lacking, before it is being applied to biomechanical research. Therefore, this study first evaluated the validity and reliability of this system in upper-body capturing and then quantified the system’s accuracy for different task complexities and movement speeds. Seven participants performed simple (eight single-DOF upper-body movements) and complex tasks (lifting a 2.5 kg box over the shoulder) at fast and slow speeds with the PNS and OptiTrack (gold-standard optical system) collecting kinematics data simultaneously. Statistical metrics such as CMC, RMSE, Pearson’s r, R2, and Bland–Altman analysis were utilized to assess the similarity between the two systems. Test–retest reliability included intra- and intersession relations, which were assessed by the intraclass correlation coefficient (ICC) as well as CMC. All upper-body kinematics were highly consistent between the two systems, with CMC values 0.73–0.99, RMSE 1.9–12.5°, Pearson’s r 0.84–0.99, R2 0.75–0.99, and Bland–Altman analysis demonstrating a bias of 0.2–27.8° as well as all the points within 95% limits of agreement (LOA). The relative reliability of intra- and intersessions was good to excellent (i.e., ICC and CMC were 0.77–0.99 and 0.75–0.98, respectively). The paired t-test revealed that faster speeds resulted in greater bias, while more complex tasks led to lower consistencies. Our results showed that the PNS could provide accurate enough upper-body kinematics for further biomechanical performance analysis.

30 November 2023 in iScience
Verified
Journal Article
Open access
YWYiwei Wu
Yiwei Wu
YSYanfei Shen
Yanfei Shen
YTYinsheng Tian
Yinsheng Tian
QCQi Chen
Qi Chen
LSLixin Sun
Lixin Sun
Ice hockey is a high-intensity sport in which pads such as shoulder and elbow pads (S/EPs) are necessary to help players avoid injury. However, they can also affect mobility and comfort, thereby affecting players’ on-ice performance. We aimed to quantify the effects of S/EPs on mobility and comfort by comparing the range of motion (ROM) of nine elite college-level ice hockey players performing static (nine single-DOF upper-body movements) and dynamic (wrist and slap shots) tasks under six pad conditions (no S/EPs and five types of S/EPs). We also analyzed the relationship between ROM and subjective comfort to provide an objective comfort evaluation of hockey pads. Five types of S/EPs restrict ROM at different levels, imposing additional mobility restrictions. We found significant differences among the five types and a high correlation between comfort and ROM. We conducted a comprehensive evaluation of the impact of ice hockey pads on mobility and comfort.

12 February 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
YLYongqing Liu
Yongqing Liu
QCQi Chen
Qi Chen
GNSS is widely used in professional athletic training as an outdoor location based services, and the indoor positioning technology has gradually flourished in the gymnasium. To keep up with the demand for athletic training in indoor and outdoor environment, integration of indoor and outdoor positioning technology can achieve a seamless indoor/outdoor position solution. The proposed method uses GPS/BEIDOU with IMU-MEMS technology for outdoor positioning and UWB with IMU-MEMS technology for indoor positioning to provide high precision positioning services. The experimental results show that the proposed method can achieve meter level position accuracy in outdoor environment and centimeter level position accuracy in indoor environment, it can provide precise and real-time positioning service for effective athletic training aid.

11 February 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
QHQi Hu
Qi Hu
QCQi Chen
Qi Chen
YLYongqing Liu
Yongqing Liu
QZQingkai Zhen
Qingkai Zhen
In the sport science fields, for a long time there are various attempts to explore more advanced technology in order to collect kinds of information concerned during athletes training and matches. In the paper, a footwork training and testing system has been developed by adopting the advanced technology of Wireless Sensor Network (WSN). The system is comprised of some wireless senor nodes and gateways, system control software and so on. By means of the system, the daily footwork training methods and modes will be simulated to automatically guide the training of the athletes, at the same time the training data concerned will be automatically recorded, including moving velocity, moving frequency and success average, moving exercise duration and so on, and it is facilitate to evaluate digitally the training and testing effects for coaches and athletes. The system will bring about an auxiliary means in sport science training and research, make coaches and researchers have more options for the technical and information forms, and provide the technology foundation for synchronizing and intermingling the training and testing smoothly.

12 February 2018 in Proceedings
Verified
Conference Paper
Open access
PDF file
QZQingkai Zhen
Qingkai Zhen
YLYongqing Liu
Yongqing Liu
QHQi Hu
Qi Hu
QCQi Chen
Qi Chen
The number of steps can be used to measure the distance, intensity, frequency, and oxygen consumption of the human activities indirectly, it has great significance to evaluate the amount of human movement. Different from traditional methods which based on wearable sensors, video based methods have the advantages of non-contact. In this paper, we propose a novel infrared video based accurate step counting algorithm for treadmills. Our approach is mainly divided into two parts, e.g., shoulder tracking and step counting. Shoulder movement is less disturbed and can accurately reflect the gait information than other body parts in the processing of running. By tracking the position of the shoulder in the image sequence, and analyzing the peaks and troughs of the trajectory, we can calculate the number of steps accurately in real time. The experiments are conducted on our own datasets, and the result achieved clearly demonstrate the effectiveness of the proposed method.