Emanuela Maria Roldi

Emanuela Maria Roldi

Auto-generated profile, based on publicly available information

Emanuela Maria Roldi

Department of Anaesthesia and Intensive Care, Istituto di Ricovero e Cura a Carattere Scientifico, Policlinico San Matteo Foundation, University of Pavia, Italy

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 September 2019 in Anaesthesia
Verified
Journal Article
Closed access
PDF file
ODO. Dransart‐Rayé
O. Dransart‐Rayé
ERE. Roldi
E. Roldi
LZL. Zieleskiewicz
L. Zieleskiewicz
PGP. G. Guinot
P. G. Guinot
FMF. Mojoli
F. Mojoli
BBBelaid Bouhemad
Belaid Bouhemad

1 March 2019 in European Journal of Anaesthesiology
Verified
Journal Article
Closed access
EREmanuela Roldi
Emanuela Roldi
PIPaolo Inghileri
Paolo Inghileri
ODOphélie Dransart-Raye
Ophélie Dransart-Raye
SMSilvia Mongodi
Silvia Mongodi
PGPierre-Grégoire Guinot
Pierre-Grégoire Guinot
BBBelaïd Bouhemad
Belaïd Bouhemad
Left double-lumen tubes (LDLTs) are used in thoracic surgery to allow one-lung ventilation. Their size is usually chosen on the basis of clinical parameters (height, sex). Double-lumen endobronchial tubes are frequently undersized/oversized, risking tube displacement or tracheal trauma. A correlation between ultrasound tracheal diameter and left main bronchus dimension has been demonstrated. We hypothesised that the insertion of undersized/oversized double-lumen tubes is frequent when the size is selected using standard criteria, and that the use of ultrasound to estimate tracheal diameter may help to reduce the frequency of insertion of oversized tubes. Two-step prospective observational study. The operating room of a French University hospital from January 2016 to February 2017. We enrolled 102 and 50 consecutive patients undergoing elective thoracic surgery in Steps 1 and 2 (males 63.7 and 60.0%, age 63 (13) and 63 (11) years, height 170 (13) and 169 (9) cm, respectively). In Step 1, the size of the LDLT inserted was selected on the basis of clinical parameters. Ultrasound data about tracheal diameter were collected to determine cut-off points associating height and tracheal diameter. Cut-off values for ultrasound tracheal diameter were applied retrospectively to test their capability to reduce the insertion rate of oversized tube. In Step 2, the LDLT size was chosen according to the determined combined cut-off values. LDLT size was considered adequate if the bronchial cuff volume required for isolation of the lung (i.e. no difference between inspiratory and expiratory lung volumes) was 0.5 to 2.5 ml of air; undersized and oversized tubes required more than 2.5 ml and less than 0.5 ml, respectively. In Step 1, LDLT size was appropriate/undersized/oversized in 40 (39.2%)/23 (22.6%)/39 (38.6%) of patients. Cut-off values derived from ultrasound measurements would have reduced the use of oversized tubes by 20.6% (P < 0.001). In Step 2, the frequency of use of adequately sized tubes increased (86.0 vs. 39.2%, P < 0.001), and the frequency of insertion of oversized and undersized tubes decreased (6.0 vs. 38.2% and 8.0 vs. 22.6%, both P < 0.001). Combining ultrasound measurement of tracheal diameter and clinical parameters improves the choice of LDLT size.

21 March 2017 in Critical Care
Verified
Journal Article
Open access
PDF file
DRD. Rob
D. Rob
RŠR. Špunda
R. Špunda
JLJ. Lindner
J. Lindner
JŠJ. Šmalcová
J. Šmalcová
OŠO. Šmíd
O. Šmíd
BDB. Doyle
B. Doyle
Introduction: Ventricular septal rupture (VSR) is an unusual mechanical complication of myocardial infarction (MI) in the era of reperfusion therapy, but the mortality rate of patients who present with cardiogenic shock (CS) remains extremely high. Whereas current American and European guidelines recommend urgent surgical repair regardless of hemodynamic status, promising outcomes have been repeatedly reported with the use of circulatory support, enabling hemodynamic stabilization and delaying repair after consolidation of the infarct scar. Therefore, we analyzed our experience with the use of Veno-Arterial Extracorporeal Membrane Oxygenation (V-A ECMO) in post-infarction VSR. Methods: We conducted a retrospective search of institutional database of all patients presenting with post-infarction VSR from January 2007 to June 2016. Data of 33 consecutive patients were retrospectively reviewed and analyzed. Results: In our center, 7 out of 33 patients with post-MI VSR and refractory CS (despite vasopressor and intraaortic balloon pump therapy) received V-A ECMO support. V-A ECMO improved end-organ perfusion with lower lactate levels 24 hours after implantation (7.514 vs. 1.514, p < 0.005), normalized arterial pH (7.25 vs. 7.40, p < 0.036), improved mean arterial pressure (64 mm/Hg vs. 83 mm/Hg, p < 0.001) and lowered heart rate (115/min vs. 68/min, p < 0.001) in all patients. Mean duration of ECMO support was 12 days, 5 out of 7 patients underwent surgical repair, 4 were successfully weaned from ECMO, 3 survived 30 days and 2 survived more than 1 year. The most frequent complication (5 patients) as well as the cause of death (3 patients) was bleeding. Conclusions: Our experience suggest that V-A ECMO support in patients with VSR and refractory CS improves end-organ perfusion, provides hemodynamic stabilization and increases time for cardiovascular team decision. Bleeding complications are an important limitation of this method.

21 March 2017 in Critical Care
Verified
Journal Article
Open access
PDF file
SGSR The SRLF Trial Group
SR The SRLF Trial Group
VKV. Karavana
V. Karavana
ISI. Smith
I. Smith
GKG. Kanellis
G. Kanellis
ISI. Sigala
I. Sigala
LAL. Azevedo
L. Azevedo

1 January 2019 in Chest
Verified
Journal Article
Closed access
SMSilvia Mongodi
Silvia Mongodi
MLMarta Luperto
Marta Luperto
EREmanuela Maria Roldi
Emanuela Maria Roldi
AOAnita Orlando
Anita Orlando
GIGiorgio Antonio Iotti
Giorgio Antonio Iotti
FMFrancesco Mojoli
Francesco Mojoli

1 September 2017 in Chest
Verified
Journal Article
Closed access
PDF file
SMSilvia Mongodi
Silvia Mongodi
EREmanuela Maria Roldi
Emanuela Maria Roldi
AOAnita Orlando
Anita Orlando
LCLuca Civardi
Luca Civardi
GIGiorgio Antonio Iotti
Giorgio Antonio Iotti
FMFrancesco Mojoli
Francesco Mojoli