Fabrizio Vatta

Fabrizio Vatta

Auto-generated profile, based on publicly available information

Fabrizio Vatta

Department of Pediatric Surgery and Urology, Hôpital Necker-Enfants Malades, Paris, France

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2023 in Annals of Surgery
Verified
Journal Article
Closed access
NVNicolas Vinit
Nicolas Vinit
FVFabrizio Vatta
Fabrizio Vatta
ABAline Broch
Aline Broch
MHMary Hidalgo
Mary Hidalgo
JKJules Kohaut
Jules Kohaut
TBThomas Blanc
Thomas Blanc
Objective: To report one-year morbidity of robotic-assisted laparoscopic surgery (RALS) in a dedicated, multidisciplinary, pediatric robotic surgery program. Summary Background Data. RALS in pediatric surgery is expanding, but data on morbidity in children is limited. Methods: All children who underwent RALS (Da Vinci Xi, Intuitive Surgical, USA) were prospectively included (October 2016 to May 2020; follow-up ≥1 year). Analyzed data: patient characteristics, surgical indication/procedure, intraoperative adverse events (ClassIntra classification), blood transfusion, hospital stay, postoperative complications (Clavien-Dindo). Results: Three hundred consecutive surgeries were included: urology/gynecology (n=105), digestive surgery (n=83), oncology (n=66), ENT surgery (n=28), thoracic surgery (n=18). Median age and weight at surgery were 9.5 [interquartile range (IQR)=8.8] years and 31 [IQR=29.3] kg, respectively. Over one year, 65 (22%) children presented with ≥1 complication, with Clavien-Dindo ≥III in 14/300 (5%) children at ≤30 days, 7/300 (2%) at 30-90 days, and 12/300 (4%) at >90 days. Perioperative transfusion was necessary in 15 (5%) children, mostly oncological (n=8). Eight (3%) robotic malfunctions were noted, one leading to conversion (laparotomy). Overall conversion rate was 4%. ASA ≥3, weight ≤15 kg, and surgical oncology did not significantly increase the conversion rate, complications, or intraoperative adverse events (ClassIntra ≥2). ASA score was significantly higher in children with complications (Clavien-Dindo ≥III) than without (p=0.01). Median hospital stay was 2 [IQR=3] days. Three children died after a median follow-up of 20 [IQR=16] months. Conclusions: RALS is safe, even in the most vulnerable children with a wide scope of indications, age, and weight. Robot-specific complications or malfunctions are scarce.

1 September 2021 in Journal of Pediatric Surgery
Verified
Journal Article
Closed access
MDMarion Durand
Marion Durand
LMLayla Musleh
Layla Musleh
FVFabrizio Vatta
Fabrizio Vatta
GOGiorgia Orofino
Giorgia Orofino
SQStefania Querciagrossa
Stefania Querciagrossa
NKNaziha Khen-Dunlop
Naziha Khen-Dunlop

1 December 2021 in Journal of Laparoendoscopic & Advanced Surgical Techniques
Verified
Journal Article
Closed access
MBMirko Bertozzi
Mirko Bertozzi
MRMaria Ruffoli
Maria Ruffoli
FVFabrizio Vatta
Fabrizio Vatta
MGMarta Gazzaneo
Marta Gazzaneo
ARAlessandro Raffaele
Alessandro Raffaele
GRGiovanna Riccipetitoni
Giovanna Riccipetitoni
Background: Lymphangiomas represent 5% of all benign pediatric tumors. Abdominal lymphangiomas (ALs) are extremely rare. Therapy includes surgery, sclerotherapy, or pharmacological treatment. Laparoscopic resection (LR) has been already described, but mainly as case reports. The aim of this study is to present our series of ALs LR. Materials and Methods: From 2007 to 2020, 10 cases of ALs were electively treated by LR. Patients' age ranged from 4 months to 14 years. Preoperative diagnosis was achieved by ultrasonography and magnetic resonance images. In all cases LR was performed with four trocars: a 10 mm transumbilical trocar for camera and extraction and three 3–5 mm operative trocars. Results: Lymphangiomas arise from mesocolon in 5 giant cases, ileal mesentery in 3 and right adrenal gland in 2. LR was achieved without intraoperative complications and need of conversion in all cases. Two giant cases needed a percutaneous puncture under laparoscopic view to gain working space. A minimal ileal resection by video-assisted procedure was carried out in 2. Median hospital length was 4 days; no recurrence of disease at serial ultrasound examinations was seen at median follow-up of 5.9 years. Discussion: Several approaches have been proposed for AL treatment. The main challenges are the huge dimensions, the difficulty to achieve a complete resection, and the risk of recurrence. In this series, elective LR of ALs resulted as feasible and effective, and we consider it the standard surgical therapy.

1 June 2021 in Anaesthesia Critical Care & Pain Medicine
Verified
Journal Article
Closed access
CHCaroline Harte
Caroline Harte
MRMelissa Ren
Melissa Ren
SQStefania Querciagrossa
Stefania Querciagrossa
EDEmilie Druot
Emilie Druot
FVFabrizio Vatta
Fabrizio Vatta
TBThomas Blanc
Thomas Blanc

19 January 2022 in Journal of Pediatric Urology
Verified
Journal Article
Closed access
EBEnrico Brönnimann
Enrico Brönnimann
IAIlona Alova
Ilona Alova
FVFabrizio Vatta
Fabrizio Vatta
TBThomas Blanc
Thomas Blanc
HLHenri Lottmann
Henri Lottmann

1 November 2021 in Journal of Laparoendoscopic & Advanced Surgical Techniques
Verified
Journal Article
Closed access
GRGiovanna Riccipetitoni
Giovanna Riccipetitoni
GPGloria Pelizzo
Gloria Pelizzo
MRMaria Ruffoli
Maria Ruffoli
SCSilvia Cavaiuolo
Silvia Cavaiuolo
CVClaudio Vella
Claudio Vella
ARAlessandro Raffaele
Alessandro Raffaele
Purpose: We performed a retrospective study to determine the effectiveness and feasibility of articulating linear stapler in laparoscopic total splenectomy (LTS) and laparoscopic partial splenectomy (LPS), focusing on technical laparoscopic skills that could help pediatric surgeons to avoid intra- and postoperative complications. Methods: Retrospective cohort study of children younger than 18 years who underwent laparoscopic spleen surgery between January 2008 and March 2020. Age, sex, indication for surgery, operative time (OT), intra- and postoperative complications, and postoperative length of hospital stay (LHS) were analyzed. Data from parenchymal resection and vessels sealing techniques were obtained. Results: Thirty patients, 19 LTS and 11 LPS, were included. The mean age of the patients was 10.9 years, and 16 patients were male and 14 were female. For hematologic diseases, LTS was the elective surgery, associated with cholecystectomy in 5 cases. LPS was the common procedure for splenic cysts. The stapler was used in LTS to close the hilum vessels and in LPS for parenchymal resection. No statistically significant differences in OT were observed comparing LTS and LPS. Two conversions occurred in LTS; none in LPS. The mean LHS was 6 days in both groups. No recurrence or major complications appeared in both groups at 1–12 years of follow-up. In particular for LPS, there are no relapse of cyst neither reduction in splenic function. Conclusions: This study shows the effectiveness, feasibility, and safety of mechanic stapler in splenic surgery both for hilum vessels sealing and for parenchymal resection. The use of this device can reduce risk of hemorrhagic recurrences or major surgical complications improving the safety of the operation.