Aina Queral-Beltran

Aina Queral-Beltran

Auto-generated profile, based on publicly available information

Aina Queral-Beltran

Institute of Environmental Assessment and Water Research (IDAEA-CSIC), Department of Environmental Chemistry, Jordi Girona 18-26, Barcelona, 08034, Spain; Department of Chemical Engineering and Analytical Chemistry, Faculty of Chemistry, University of Barcelona, Martí i Franquès 1-11, Barcelona, 08028, Spain

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2025 in Environmental Science & Technology Letters
Verified
Journal Article
Open access
DBDamalka Balasuryia
Damalka Balasuryia
AQAina Queral-Beltran
Aina Queral-Beltran
TVTristan Vick
Tristan Vick
SSScott Simpson
Scott Simpson
SLSilvia Lacorte
Silvia Lacorte
AHAlexander C. Hoepker
Alexander C. Hoepker
Accurate pK a values of per- and polyfluoroalkyl substances (PFAS) are urgently needed to improve predictions of their environmental fate, bioaccumulation, and removal, yet reliable experimental data remain scarce. Here, we determined the pK a values of 10 PFAS and three short-chain fluorinated acids (MFA: 2.58 ± 0.03; DFA: 1.22 ± 0.03, TFA: 0.03 ± 0.08) using 19F and 1H NMR-based chemical shift perturbation. Results were compared to prior experimental values, OPERA predictions (CompTox), and our COSMO-RS calculations. Measured pK a values include PFPrA (−0.18 to −0.54), PFOA (−0.27 ± 0.18), PFBS and PFOS (< −1.85), 6:2 FTS (<0.0), GenX (−0.20 ± 0.09), NFDHA (−0.32 ± 0.18), PFMPA (−0.26 ± 0.13), and 6:2 FTUCA (2.59 ± 0.11). Across C2, C3, and C8 homologues, PFCAs exhibit pK a values of approximately −0.2 to −0.3. Telomerization markedly reduces acidity: 5:3 FTCA (pK a = 4.05 ± 0.04) is >104-fold less acidic than PFOA, with COSMO-RS predicting similar effects from PFOS to 6:2 FTS. The dominant acidifying influence arises from CF2 groups at C1 and C2 near COOH or SO3H. The unusually low pK a values for TFA, PFOA, and GenX reflect our low-MeOH, sorption-resistant NMR method. COSMO-RS consistently outperformed OPERA, underscoring the need for experimental benchmarks to improve predictive models for emerging PFAS.

2 July 2023 in Analytica Chimica Acta
Verified
Journal Article
Open access
AQAina Queral-Beltran
Aina Queral-Beltran
MMMarc Marín-García
Marc Marín-García
SLSilvia Lacorte
Silvia Lacorte
RTRoma Tauler
Roma Tauler
Sulfamethoxazole (SMX) is one of the most widely used antibiotics worldwide and has been detected at high concentrations in wastewater treatment plant effluents and river waters. In this study, the SMX degradation process combining the simultaneous chlorine oxidation and UV photodegradation is assessed and compared with both photodegradation and chlorine oxidation processes individually. Photodegradation and Chlorine/UV tests were performed using Suntest CPS equipment. Different experimental techniques, including UV-Visible spectrophotometry and liquid chromatography coupled to a diode array detector and positive and negative ionization mass spectrometry (LC-DAD-MS-ESI(+)-ESI(-)), were used to evaluate the degradation reaction of SMX. All the analytical data generated have been processed with the Multivariate Curve Resolution-Alternating Least Squares (MCR-ALS) method to monitor, resolve, and identify the several transformation products generated during the studied degradation processes. A new data fusion analysis strategy is proposed to examine the three processes simultaneously (with only photodegradation, only chlorination, and simultaneous chlorination+photodegradation). Combined with the analysis of different analytical techniques individually (spectrophotometry, LC-DAD, and LC-MS), the fusion of all generated data improved the description of the degradation processes. Detection using DAD allowed a better correspondence among the species monitored spectrophotometrically (UV-Vis) with those analyzed chromatographically. On the other side, detection using MS in both positive and negative acquisition modes allowed resolving a larger number of chemical compounds (specially SMX degradation subproducts) that could not be detected by UV-Vis spectrometry. The results obtained permitted the comparison of the effects produced by the three different degradation processes.

1 February 2024 in Chemometrics and Intelligent Laboratory Systems
Verified
Journal Article
Open access
AQAina Queral-Beltran
Aina Queral-Beltran
MMMarc Marín-García
Marc Marín-García
SLSilvia Lacorte
Silvia Lacorte
RTRoma Tauler
Roma Tauler

16 November 2025 in Analytica Chimica Acta
Verified
Journal Article
Open access
AQA. Queral-Beltran
A. Queral-Beltran
SLS. Lacorte
S. Lacorte
RTRoma Tauler
Roma Tauler
The use of fish-based reference materials allows the validation of analytical methods used for the monitoring of persistent organic pollutants (POPs) in environmental samples. Thus, the aim of this work has been to apply and validate the Regions of Interest Multivariate Curve Resolution (ROIMCR) procedure, in a first instance, to quantify POPs using two fish-based certified reference materials (CRM) provided by the Institute of Reference Materials (IRMM); and also to identify, with the MSident program, the presence of more POPs in the same samples. Samples were extracted and analyzed by gas chromatography coupled to an Orbitrap mass spectrometer (GC-HRMS). A targeted analysis was performed to quantify the four certified POPs: hexachlorobenzene (HCBz) and hexachlorobutadiene (HCBu) in ERM®-CE100 and pentachlorobenzene (PeCB) and α, β, γ, and δ-hexachlorocyclohexane (HCH) in ERM®-CE103. Quantitative estimations obtained with ROIMCR method were compared with those obtained using the instrument vendor's Xcalibur software. Two tailed t-tests were performed and good agreement was observed between the two approaches and with the certified values. A non-targeted analysis approach was then performed to characterize other unknown POPs present in the samples. Data processed with the ROIMCR method in the non-targeted acquisition mode was complemented with the MSident chemical identification procedure, which allowed the annotation of several polycyclic aromatic hydrocarbons (PAHs), organochlorine pesticides (OCPs), phthalates, and polychlorinated biphenyls (PCBs). The presence of some of these compounds was confirmed with the analysis of validation standard mixture samples containing 43 POPs. The ROIMCR methodology herein proposed allows, in a first instance, the quantitative analysis of multiple unknown contaminants present in the analyzed fish-based certified samples by using GC-HRMS data and also, combined with the MSident program, enables a qualitative analysis which could provide a comprehensive assessment of POP pollution patterns in fish or other environmental samples.