Rebecca J. Even

Rebecca J. Even

Auto-generated profile, based on publicly available information

Rebecca J. Even

Department of Soil and Crop Sciences, Colorado State University, Fort Collins, CO 80523, USA

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 December 2023 in Global Change Biology
Verified
Journal Article
Closed access
PHPaige M. Hansen
Paige M. Hansen
RERebecca Even
Rebecca Even
AKAlison E. King
Alison E. King
JLJocelyn Lavallee
Jocelyn Lavallee
MSMeagan Schipanski
Meagan Schipanski
FCFrancesca Cotrufo
Francesca Cotrufo

8 January 2025 in SOIL
Verified
Journal Article
Open access
PDF file
RERebecca J. Even
Rebecca J. Even
MMMegan B. Machmuller
Megan B. Machmuller
JLJocelyn M. Lavallee
Jocelyn M. Lavallee
TZTamara J. Zelikova
Tamara J. Zelikova
MCM. Francesca Cotrufo
M. Francesca Cotrufo
To build confidence in the efficacy of soil carbon (C) crediting programs, precise quantification of soil organic carbon (SOC) is critical. Detecting a true change in SOC after a management shift has occurred, specifically in agricultural lands, is difficult as it requires robust soil sampling and soil processing procedures. Informative and meaningful comparisons across spatial and temporal timescales can only be made with reliable soil C measurements and estimates, which begin on the ground and in soil testing facilities. To gauge soil C measurement inter-variability, we conducted a blind external service laboratory comparison across eight laboratories selected based on status and involvement in SOC data curation used to inform C market exchanges, which could include demonstration projects, model validation, and project verification activities. Further, to better understand how soil processing procedures and quantification methods commonly used in soil testing laboratories affect soil C concentration measurements, we designed an internal experiment assessing the individual effect of several alternative procedures (i.e., sieving, fine grinding, and drying) and quantification methods on total (TC), inorganic (SIC), and organic (SOC) soil C concentration estimates. We analyzed 12 different agricultural soils using 11 procedures that varied in either the sieving, fine-grinding, drying, or quantification step. We found that a mechanical grinder, the most commonly used method for sieving in service laboratories, did not effectively remove coarse materials (i.e., roots and rocks) and thus resulted in higher variability and significantly different C concentration measurements from the other sieving procedures (i.e., 8 + 2, 4, and 2 mm with a rolling pin). A finer grind generally resulted in a lower coefficient of variance, where the finest grind to < 125 µm had the lowest coefficient of variance, followed by the < 250 µm grind and, lastly, the < 2000 µm grind. Not drying soils in an oven prior to elemental analysis on average resulted in a 3.5 % lower TC and 5 % lower SOC relative to samples dried at 105 °C due to inadequate removal of moisture. Compared to the reference method used in our study where % TC was quantified by dry combustion on an elemental analyzer, % SIC was measured using a pressure transducer, and % SOC was calculated by the difference in % TC and % SIC, predictions of all three soil properties (% TC, % SIC, and % SOC) using Fourier-transformed infrared spectroscopy (FTIR) were in high agreement (R2 = 0.97, 0.99, and 0.90, respectively). For % SOC, quantification by loss on ignition had a relatively low coefficient of variance (5.42 ± 3.06 %) but the least agreement (R2 = 0.83) with the reference method. We conclude that sieving to < 2 mm with a mortar and pestle or rolling pin to remove coarse materials, drying soils at 105 °C, and fine-grinding soils prior to elemental analysis are required to improve accuracy and precision of soil C measurements. Moreover, we show promising results using FTIR spectroscopy coupled with predictive modeling for estimating % TC, % SIC, and % SOC in regions where spectral libraries exist.


24 May 2024
Verified
Other
Open access
RERebecca J. Even
Rebecca J. Even
MMMegan B. Machmuller
Megan B. Machmuller
JLJocelyn M. Lavallee
Jocelyn M. Lavallee
TZTamara J. Zelikova
Tamara J. Zelikova
MCM. Francesca Cotrufo
M. Francesca Cotrufo

24 May 2024 in EGUsphere
Verified
Preprint
Open access
PDF file
RERebecca J. Even
Rebecca J. Even
MMMegan B. Machmuller
Megan B. Machmuller
JLJocelyn M. Lavallee
Jocelyn M. Lavallee
TZTamara J. Zelikova
Tamara J. Zelikova
MCM. Francesca Cotrufo
M. Francesca Cotrufo
To build confidence in the efficacy of soil carbon (C) crediting programs, precise quantification of soil organic carbon C (SOC) is critical. Detecting a true change in SOC after a management shift has occurred, specifically in agricultural lands, is difficult as it requires robust soil sampling and soil processing procedures. Informative and meaningful comparisons across spatial and temporal time scales can only be made with reliable soil C measurements and estimates, which begin on the ground and in soil testing facilities. To gauge soil C measurement inter-variability, we conducted a blind external service laboratory comparison across eight laboratories selected based on status and involvement in SOC quantification for C markets. To better understand how soil processing procedures and quantification methods commonly used in soil testing laboratories affect soil C concentration measurements, we designed an internal experiment assessing the individual effect of several alternative procedures (i.e., sieving, fine grinding, and drying) and quantification methods on total (TC), inorganic (SIC), and organic (SOC) soil C concentration estimates. We analyzed 12 different agricultural soils using 11 procedures that varied either in the sieving, fine grinding, drying, or quantification step. We found that a mechanical grinder, the most commonly used method for sieving in service laboratories, did not effectively remove coarse materials (i.e., roots and rocks), thus resulted in higher variability and significantly different C concentration measurements from the other sieving procedures (i.e., 8 + 2 mm, 4 mm, and 2 mm with rolling pin). A finer grind generally resulted in a lower coefficient of variance where the finest grind to < 125 µm had the lowest coefficient of variance, followed by the < 250 µm grind, and lastly the < 2000 µm grind. Not drying soils in an oven (at 105 °C) prior to elemental analysis on average resulted in a relative difference of 3.5 % lower TC, and 5 % lower SOC due to inadequate removal of moisture. Compared to the reference method used in our study where % TC was quantified by dry combustion on an elemental analyzer, % SIC was measured using a pressure transducer, and % SOC was calculated by the difference of % TC and % SIC, predictions of all three soil properties (% TC, % SIC, % SOC) using Fourier Transformed Infrared Spectroscopy were in high agreement (R2 = 0.97, 0.99, 0.90, respectively). For % SOC, quantification by loss on ignition had a low coefficient of variance (5.42 ± 3.06 %) but the least agreement (R2 = 0.83) with the reference method.

14 August 2024
Verified
Other
Open access
PDF file
RERebecca J. Even
Rebecca J. Even
MMMegan B. Machmuller
Megan B. Machmuller
JLJocelyn M. Lavallee
Jocelyn M. Lavallee
TZTamara J. Zelikova
Tamara J. Zelikova
MCM. Francesca Cotrufo
M. Francesca Cotrufo
To build confidence in the efficacy of soil carbon (C) crediting programs, precise quantification of soil organic carbon C (SOC) is critical. Detecting a true change in SOC after a management shift has occurred, specifically in agricultural lands, is difficult as it requires robust soil sampling and soil processing procedures. Informative and meaningful comparisons across spatial and temporal time scales can only be made with reliable soil C measurements and estimates, which begin on the ground and in soil testing facilities. To gauge soil C measurement inter-variability, we conducted a blind external service laboratory comparison across eight laboratories selected based on status and involvement in SOC quantification for C markets. To better understand how soil processing procedures and quantification methods commonly used in soil testing laboratories affect soil C concentration measurements, we designed an internal experiment assessing the individual effect of several alternative procedures (i.e., sieving, fine grinding, and drying) and quantification methods on total (TC), inorganic (SIC), and organic (SOC) soil C concentration estimates. We analyzed 12 different agricultural soils using 11 procedures that varied either in the sieving, fine grinding, drying, or quantification step. We found that a mechanical grinder, the most commonly used method for sieving in service laboratories, did not effectively remove coarse materials (i.e., roots and rocks), thus resulted in higher variability and significantly different C concentration measurements from the other sieving procedures (i.e., 8 + 2 mm, 4 mm, and 2 mm with rolling pin). A finer grind generally resulted in a lower coefficient of variance where the finest grind to < 125 µm had the lowest coefficient of variance, followed by the < 250 µm grind, and lastly the < 2000 µm grind. Not drying soils in an oven (at 105 °C) prior to elemental analysis on average resulted in a relative difference of 3.5 % lower TC, and 5 % lower SOC due to inadequate removal of moisture. Compared to the reference method used in our study where % TC was quantified by dry combustion on an elemental analyzer, % SIC was measured using a pressure transducer, and % SOC was calculated by the difference of % TC and % SIC, predictions of all three soil properties (% TC, % SIC, % SOC) using Fourier Transformed Infrared Spectroscopy were in high agreement (R2 = 0.97, 0.99, 0.90, respectively). For % SOC, quantification by loss on ignition had a low coefficient of variance (5.42 ± 3.06 %) but the least agreement (R2 = 0.83) with the reference method.