6 May 2012 in Experimental Astronomy
1 September 2007 in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
1 April 2017 in Journal of Instrumentation
We describe improvements in CCD performance that have been achieved on 4k×4k, (15 μm)2-pixel, fully depleted CCDs for the Dark Energy Spectroscopic Instrument (DESI) [1]. With respect to our previous work on CCDs for the Dark Energy Camera and the Baryon Oscillation Spectroscopic Survey, our goals for the DESI CCD development were to improve read noise and quantum efficiency, improve the astrometric precision, and decrease pixel-size variations. We report experimental results on recently fabricated CCDs to be used in DESI.
24 May 2023 in Astronomische Nachrichten
We describe the advancement of fully depleted charge‐coupled device (CCD) technology for scientific applications. Recent efforts on 650–725 m‐thick CCDs for direct dark‐matter and radiation detection with single‐electron sensitivity are described, as well as the technology transfer of the fully depleted CCD technology to 200 mm‐wafer fabrication facilities.
26 April 2022 in Physical Review Applied
We present experimental results using a single-electron resolution skipper CCD running above ground level to demonstrate the potential of this technology for its use in reactor neutrino observations and other low-energy particle-interaction experiments. Operating conditions and event-selection criteria are provided to decouple most of the background rate at low energies. The majority of this background comes from interactions in the inactive silicon surrounding the active detector volume that ends up in the readout register of the sensor. Our final results are compared with other low-threshold technologies showing a good control of the background for low ionization energies down to five electron-hole pairs. This demonstrates that the skipper CCD proves to be among the best options to measure low-energy and weakly interacting particles at ground level.
1 September 2024 in Publications of the Astronomical Society of the Pacific
We present characterization results and performance of a prototype Multiple-Amplifier Sensing (MAS) silicon charge-coupled device (CCD) sensor with 16 channels potentially suitable for faint object astronomical spectroscopy and low-signal, photon-limited imaging. The MAS CCD is designed to reach sub-electron readout noise by repeatedly measuring charge through a line of amplifiers during the serial transfer shifts. Using synchronized readout electronics based on the Dark Energy Spectroscopic Instrument CCD controller, we report a read noise of 1.03 e− rms pix−1 at a speed of 26 μs pix−1 with a single-sample readout scheme where charge in a pixel is measured only once for each output stage. At these operating parameters, we find the amplifier-to-amplifier charge transfer efficiency (ACTE) to be >0.9995 at low counts for all amplifiers but one for which the ACTE is 0.997. This charge transfer efficiency falls above 50,000 electrons for the read-noise optimized voltage configuration we chose for the serial clocks and gates. The amplifier linearity across a broad dynamic range from ∼300 to 35,000 e− was also measured to be ±2.5%. We describe key operating parameters to optimize on these characteristics and describe the specific applications for which the MAS CCD may be a suitable detector candidate.